Modeling Fluorescence Recovery After Photobleaching in Loaded Bone: Potential Applications in Measuring Fluid and Solute Transport in the Osteocytic Lacunar-Canalicular System

被引:38
|
作者
Zhou, Xiaozhou [1 ]
Novotny, John E. [1 ]
Wang, Liyun [1 ]
机构
[1] Univ Delaware, Dept Mech Engn, Biomed Engn Res Ctr, Spencer Lab 126, Newark, DE 19716 USA
关键词
Bone; Osteocyte; FRAP; Fluid flow; Solute transport; Strouhal number; Intermittent loading;
D O I
10.1007/s10439-008-9566-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Solute transport through the bone lacunar-canalicular system is essential for osteocyte viability and function, and it can be measured using fluorescence recovery after photobleaching (FRAP). The mathematical model developed here aims to analyze solute transport during FRAP in mechanically loaded bone. Combining both whole bone-level poroelasticity and cellular-level solute transport, we found that load-induced solute transport during FRAP is characterized by an exponential recovery rate, which is determined by the dimensionless Strouhal (St) number that characterizes the oscillation effects over the mean flows, and that significant transport occurs only for St values below a threshold, when the solute stroke displacement exceeds the distance between the source and sink (the canalicular length). This threshold mechanism explains the general flow behaviors such as increasing transport with increasing magnitude and decreasing frequency. Mechanical loading is predicted to enhance transport of all tracers relative to diffusion, with the greatest enhancement for medium-sized tracers and less enhancement for small and large tracers. This study provides guidelines for future FRAP experiments, based on which the model can be used to quantify bone permeability, solute-matrix interaction, and flow velocities. These studies should provide insights into bone adaptation and metabolism, and help to treat various bone diseases and conditions.
引用
收藏
页码:1961 / 1977
页数:17
相关论文
共 10 条
  • [1] Modeling Fluorescence Recovery After Photobleaching in Loaded Bone: Potential Applications in Measuring Fluid and Solute Transport in the Osteocytic Lacunar-Canalicular System
    Xiaozhou Zhou
    John E. Novotny
    Liyun Wang
    Annals of Biomedical Engineering, 2008, 36 : 1961 - 1977
  • [2] Quantification of Lacunar-Canalicular Interstitial Fluid Flow Through Computational Modeling of Fluorescence Recovery After Photobleaching
    Kwon, Ronald Y.
    Frangos, John A.
    CELLULAR AND MOLECULAR BIOENGINEERING, 2010, 3 (03) : 296 - 306
  • [3] Solute Transport in the Bone Lacunar-Canalicular System (LCS)
    Liyun Wang
    Current Osteoporosis Reports, 2018, 16 : 32 - 41
  • [4] Solute Transport in the Bone Lacunar-Canalicular System (LCS)
    Wang, Liyun
    CURRENT OSTEOPOROSIS REPORTS, 2018, 16 (01): : 32 - 41
  • [5] In situ measurement of solute transport in the bone lacunar-canalicular system
    Wang, LY
    Wang, YL
    Han, YF
    Henderson, SC
    Majeska, RJ
    Weinbaum, S
    Schaffler, MB
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (33) : 11911 - 11916
  • [6] Anatomic variations of the lacunar-canalicular system influence solute transport in bone
    Zhou, Xiaozhou
    Novotny, John E.
    Wang, Liyun
    BONE, 2009, 45 (04) : 704 - 710
  • [7] Does blood pressure enhance solute transport in the bone lacunar-canalicular system?
    Li, Wen
    Gardinier, Joseph D.
    Price, Christopher
    Wang, Liyun
    BONE, 2010, 47 (02) : 353 - 359
  • [8] Quantification of Lacunar–Canalicular Interstitial Fluid Flow Through Computational Modeling of Fluorescence Recovery After Photobleaching
    Ronald Y. Kwon
    John A. Frangos
    Cellular and Molecular Bioengineering, 2010, 3 : 296 - 306
  • [9] Impact of gravity on fluid flow and solute transport in the bone lacunar-canalicular system: a multiscale numerical simulation study
    Xing, Chao
    Wang, Hao
    Zhu, Jianzhong
    Zhang, Chunqiu
    Li, Xuejin
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (14) : 2071 - 2080
  • [10] Real-Time Measurement of Solute Transport Within the Lacunar-Canalicular System of Mechanically Loaded Bone: Direct Evidence for Load-Induced Fluid Flow
    Price, Christopher
    Zhou, Xiaozhou
    Li, Wen
    Wang, Liyun
    JOURNAL OF BONE AND MINERAL RESEARCH, 2011, 26 (02) : 277 - 285