Accuracy of some algorithms to determine the oscillometric mean arterial pressure: a theoretical study

被引:15
作者
Raamat, Rein [1 ]
Talts, Jaak [1 ]
Jagomaegi, Kersti [1 ]
Kivastik, Jana [1 ]
机构
[1] Univ Tartu, Dept Physiol, EE-50411 Tartu, Estonia
关键词
accuracy of oscillometric mean arterial pressure measurement; computer simulation; maximum amplitude algorithm; modeling; oscillation amplitude envelope; theoretical study; BLOOD-PRESSURE; CUFF; MODEL;
D O I
10.1097/MBP.0b013e32835d12f6
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To compare different algorithms to determine the oscillometric mean arterial pressure. Methods Using a computer-based model, the accuracy of five algorithms was studied: maximum amplitude algorithm, 33 and 40% formulas calculating the mean arterial pressure from oscillometrically measured systolic and diastolic pressures, and two oscillation shape-based algorithms. We examined to which extent the tested algorithms were influenced by variations in four affective factors: pulse pressure, arterial pressure pulse shape index, and two shape indices (symmetry and steepness) of the artery-cuff pressure/volume relationship. Different ranges of variation of affecting factors were applied. Results The accuracy of the oscillation shape-based algorithms was found to be higher than the accuracy of the oscillation amplitude-based algorithms. The oscillation mean shape index-based determination had an almost 2-3 times narrower error range compared with the maximum amplitude algorithm. Modeling showed that the mean arterial pressure changes resulting from the varying shape of the arterial pressure waveform cannot be measured using the oscillation amplitude-based algorithms, whereas these changes can be determined effectively using the oscillation shape-based algorithms. Conclusion The maximum amplitude algorithm has a relatively low accuracy for the estimation of the mean arterial pressure. Its error range is even larger than that of estimates calculated by the 33 or 40% formulas from the oscillometrically measured systolic and diastolic blood pressures. A considerably higher accuracy can be achieved by applying the oscillation shape-based algorithms. Blood Press Monit 18: 50-56 (C) 2013 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins. Blood Pressure Monitoring 2013, 18: 50-56
引用
收藏
页码:50 / 56
页数:7
相关论文
共 24 条
  • [1] Automatic blood pressure measurement: the oscillometric waveform shape is a potential contributor to differences between oscillometric and auscultatory pressure measurements
    Amoore, John N.
    Lemesre, Yann
    Murray, Ian C.
    Mieke, Stephan
    King, Susan T.
    Smith, Fiona E.
    Murray, Alan
    [J]. JOURNAL OF HYPERTENSION, 2008, 26 (01) : 35 - 43
  • [2] Extracting oscillometric pulses from the cuff pressure: does it affect the pressures determined by oscillometric blood pressure monitors?
    Amoore, John N.
    [J]. BLOOD PRESSURE MONITORING, 2006, 11 (05) : 269 - 279
  • [3] Oscillometric sphygmomanometers: a critical appraisal of current technology
    Amoore, John Nicholas
    [J]. BLOOD PRESSURE MONITORING, 2012, 17 (02) : 80 - 88
  • [4] Theoretical analysis of non-invasive oscillometric maximum amplitude algorithm for estimating mean blood pressure
    Baker, PD
    Westenskow, DR
    Kuck, K
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (03) : 271 - 278
  • [5] Berne R.M., 1996, PRINCIPLES PHYSL, V2nd
  • [6] How to assess mean blood pressure properly at the brachial artery level
    Bos, Willem J. W.
    Verrij, Elisabeth
    Vincent, Hieronymus H.
    Westerhof, Berend E.
    Parati, Gianfranco
    van Montfrans, Gert A.
    [J]. JOURNAL OF HYPERTENSION, 2007, 25 (04) : 751 - 755
  • [7] MECHANICS OF THE OCCLUSIVE ARM CUFF AND ITS APPLICATION AS A VOLUME SENSOR
    DRZEWIECKI, G
    BANSAL, V
    KARAM, E
    HOOD, R
    APPLE, H
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (07) : 704 - 708
  • [8] OSCILLOMETRIC DETERMINATION OF DIASTOLIC, MEAN AND SYSTOLIC BLOOD-PRESSURE - A NUMERICAL-MODEL
    FORSTER, FK
    TURNEY, D
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (04): : 359 - 364
  • [9] CHARACTERIZATION OF THE OSCILLOMETRIC METHOD FOR MEASURING INDIRECT BLOOD-PRESSURE
    GEDDES, LA
    VOELZ, M
    COMBS, C
    REINER, D
    BABBS, CF
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1982, 10 (06) : 271 - 280
  • [10] Effect of tissue mechanical properties on cuff-based blood pressure measurements
    Lan, H.
    Al-Jumaily, A. M.
    Lowe, A.
    Hing, W.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2011, 33 (10) : 1287 - 1292