Evaluation of Two Sinogram Interpolation Methods for Metal Artefacts Reduction in Computed Tomography
被引:0
|
作者:
Osman, Noor Diyana
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sains Malaysia, Cluster Oncol & Radiol Sci, Adv Med & Dent Inst, Kepala Batas, MalaysiaUniv Sains Malaysia, Cluster Oncol & Radiol Sci, Adv Med & Dent Inst, Kepala Batas, Malaysia
Osman, Noor Diyana
[1
]
Sobri, Nurul Fathin Mohamad
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sains Malaysia, Cluster Oncol & Radiol Sci, Adv Med & Dent Inst, Kepala Batas, MalaysiaUniv Sains Malaysia, Cluster Oncol & Radiol Sci, Adv Med & Dent Inst, Kepala Batas, Malaysia
Sobri, Nurul Fathin Mohamad
[1
]
Achuthan, Anusha
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sains Malaysia, Cluster Oncol & Radiol Sci, Adv Med & Dent Inst, Kepala Batas, MalaysiaUniv Sains Malaysia, Cluster Oncol & Radiol Sci, Adv Med & Dent Inst, Kepala Batas, Malaysia
Achuthan, Anusha
[1
]
Saidun, Halimatul Asma
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sains Malaysia, Cluster Oncol & Radiol Sci, Adv Med & Dent Inst, Kepala Batas, MalaysiaUniv Sains Malaysia, Cluster Oncol & Radiol Sci, Adv Med & Dent Inst, Kepala Batas, Malaysia
Saidun, Halimatul Asma
[1
]
Aziz, Mohd Zahri Abdul
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sains Malaysia, Cluster Oncol & Radiol Sci, Adv Med & Dent Inst, Kepala Batas, MalaysiaUniv Sains Malaysia, Cluster Oncol & Radiol Sci, Adv Med & Dent Inst, Kepala Batas, Malaysia
Aziz, Mohd Zahri Abdul
[1
]
Shuaib, Ibrahim Lutfi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sains Malaysia, Cluster Oncol & Radiol Sci, Adv Med & Dent Inst, Kepala Batas, MalaysiaUniv Sains Malaysia, Cluster Oncol & Radiol Sci, Adv Med & Dent Inst, Kepala Batas, Malaysia
Shuaib, Ibrahim Lutfi
[1
]
机构:
[1] Univ Sains Malaysia, Cluster Oncol & Radiol Sci, Adv Med & Dent Inst, Kepala Batas, Malaysia
来源:
2018 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES)
|
2018年
关键词:
sinogram interpolation;
metal artefact reduction;
computed tomography;
CT;
D O I:
暂无
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
In the presence of metal implant, it can induce streak artefacts appearance in computed tomography (CT) images that can degrade image quality and lead to misdiagnosis. A comparative study of two different sinogram interpolation methods for metal artefact reduction in CT images is presented. The metal part of the sinogram was determined and removed by thresholding technique. The missing part of the metal trace on the sinogram was interpolated by two interpolation methods which were cubic spline and Laplace interpolation. Both methods were applied to the selected CT images of different metal geometry and complexity. The effectiveness of both interpolation methods was compared. The results showed Laplace interpolation method produced the better results of gap filling as compared to cubic spline interpolation. But, it produces lower signal-to-noise ratio (SNR) values.