Magnetic Particle Imaging: Visualization of Instruments for Cardiovascular Intervention

被引:113
作者
Haegele, Julian [1 ]
Rahmer, Juergen [2 ]
Gleich, Bernhard [2 ]
Borgert, Joern [2 ]
Wojtczyk, Hanne [3 ]
Panagiotopoulos, Nikolaos [1 ]
Buzug, Thorsten M. [3 ]
Barkhausen, Joerg [1 ]
Vogt, Florian M. [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Clin Radiol & Nucl Med, D-23538 Lubeck, Germany
[2] Philips Technol Innovat Technol, Res Labs, Hamburg, Germany
[3] Med Univ Lubeck, Inst Med Engn, D-23538 Lubeck, Germany
关键词
D O I
10.1148/radiol.12120424
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the feasibility of different approaches of instrument visualization for cardiovascular interventions guided by using magnetic particle imaging (MPI). Materials and Methods: Two balloon (percutaneous transluminal angioplasty) catheters were used. The balloon was filled either with diluted superparamagnetic iron oxide (SPIO) ferucarbotran (25 mmol of iron per liter) or with sodium chloride. Both catheters were inserted into a vessel phantom that was filled oppositional to the balloon content with sodium chloride or diluted SPIO (25 mmol of iron per liter). In addition, the administration of a 1.4-mL bolus of pure SPIO (500 mmol of iron per liter) followed by 5 mL of sodium chloride through a SPIO-labeled balloon catheter into the sodium chloride-filled vessel phantom was recorded. Images were recorded by using a preclinical MPI demonstrator. All images were acquired by using a field of view of 3.6 x 3.6 x 2.0 cm. Results: By using MPI, both balloon catheters could be visualized with high temporal (21.54 msec per image) and sufficient spatial (<= 3 mm) resolution without any motion artifacts. The movement through the field of view, the inflation and deflation of the balloon, and the application of the SPIO bolus were visualized at a rate of 46 three-dimensional data sets per second. Conclusion: Visualization of SPIO-labeled instruments for cardiovascular intervention at high temporal resolution as well as monitoring the application of a SPIO-based tracer by using labeled instruments is feasible. Further work is necessary to evaluate different labeling approaches for diagnostic catheters and guidewires and to demonstrate their navigation in the vascular system after administration of contrast material. (C) RSNA, 2012
引用
收藏
页码:933 / 938
页数:6
相关论文
共 19 条
[1]  
[Anonymous], P ISMRM TOR
[2]  
Bohnert J, 2010, IFMBE PROC, V25, P249
[3]   Intraprocedural imaging: Flat panel detectors, rotational angiography, FluoroCT, IVUS, or still the portable C-arm? [J].
Eagleton, Matthew J. .
JOURNAL OF VASCULAR SURGERY, 2010, 52 :50S-59S
[4]   Experimental results on fast 2D-encoded magnetic particle imaging [J].
Gleich, B. ;
Weizenecker, J. ;
Borgert, J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (06) :N81-N84
[5]   Tomographic imaging using the nonlinear response of magnetic particles [J].
Gleich, B ;
Weizenecker, R .
NATURE, 2005, 435 (7046) :1214-1217
[6]  
Gleich B., 2010, Proceedings of the International Society for Magnetic Resonance in Medicine, V18, P218
[7]   Ferrohydrodynamic relaxometry for magnetic particle imaging [J].
Goodwill, P. W. ;
Tamrazian, A. ;
Croft, L. R. ;
Lu, C. D. ;
Johnson, E. M. ;
Pidaparthi, R. ;
Ferguson, R. M. ;
Khandhar, A. P. ;
Krishnan, K. M. ;
Conolly, S. M. .
APPLIED PHYSICS LETTERS, 2011, 98 (26)
[8]   Trajectory analysis for magnetic particle imaging [J].
Knopp, T. ;
Biederer, S. ;
Sattel, T. ;
Weizenecker, J. ;
Gleich, B. ;
Borgert, J. ;
Buzug, T. M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (02) :385-397
[9]   Prediction of the Spatial Resolution of Magnetic Particle Imaging Using the Modulation Transfer Function of the Imaging Process [J].
Knopp, Tobias ;
Biederer, Sven ;
Sattel, Timo F. ;
Erbe, Marlitt ;
Buzug, Thorsten M. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (06) :1284-1292
[10]   First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept [J].
Kos, Sebastian ;
Huegli, Rolf ;
Hofmann, Eugen ;
Quick, Harald H. ;
Kuehl, Hilmar ;
Aker, Stephanie ;
Kaiser, Gernot M. ;
Borm, Paul J. A. ;
Jacob, Augustinus L. ;
Bilecen, Deniz .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (03) :514-521