In vivo change in ultrasonic backscattered energy with temperature in motion-compensated images

被引:33
作者
Arthur, R. Martin [1 ]
Straube, William L. [2 ]
Trobaugh, Jason W. [3 ]
Moros, Eduardo G. [4 ]
机构
[1] Washington Univ, Sch Engn, Dept Elect & Syst Engn, St Louis, MO 63130 USA
[2] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO USA
[3] Washington Univ, Sch Med, Dept Med, St Louis, MO USA
[4] Univ Arkansas Med Sci, Dept Radiat Oncol, Little Rock, AR 72205 USA
关键词
diagnostic ultrasound; hyperthermia; in vivo study; non-invasive thermometry;
D O I
10.1080/02656730801942199
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Ultrasound is an attractive modality for non-invasive imaging to monitor temperature of tumorous regions undergoing hyperthermia therapy. Previously, we predicted monotonic changes in backscattered energy (CBE) of ultrasound with temperature for certain sub-wavelength scatterers. We also measured CBE values similar to our predictions in bovine liver, turkey breast muscle, and pork rib muscle in both 1D and 2D in in vitro studies. To corroborate those results in perfused, living tissue, we measured CBE in both normal tissue and in implanted human tumors (HT29 colon cancer line) in 7 nude mice. Images were formed by a phased-array imager with a 7.5 MHz linear probe during homogeneous heating from 37 degrees to 45 degrees C in 0.5 degrees C steps and from body temperature to 43 degrees C during heterogeneous heating. We used cross-correlation as a similarity measure in RF signals to automatically track feature displacement as a function of temperature. Feature displacement was non-uniform with a maximum value of 1 mm across all specimens during homogeneous heating, and 0.2 mm during heterogeneous heating. Envelopes of image regions, compensated for non-rigid motion, were found with the Hilbert transform then smoothed with a 3 x 3 running average filter before forming the backscattered energy at each pixel. Means of both the positive and negative changes in the BE images were evaluated. CBE was monotonic and accumulated to 4-5 dB during homogeneous heating to 45 degrees C and 3-4 dB during heterogenous heating to 43 degrees C. These results are consistent with our previous in vitro measurements and support the use of CBE for temperature estimation in vivo during hyperthermia.
引用
收藏
页码:389 / 398
页数:10
相关论文
共 38 条
[1]   Temperature dependence of ultrasonic backscattered energy in motion-compensated images [J].
Arthur, RM ;
Trobaugh, JW ;
Straube, WL ;
Moros, EG .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (10) :1644-1652
[2]   Non-invasive estimation of hyperthermia temperatures with ultrasound [J].
Arthur, RM ;
Straube, WL ;
Trobaugh, JW ;
Moros, EG .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2005, 21 (06) :589-600
[3]  
Arthur RM, 2003, ULTRASON, P990
[4]   Noninvasive temperature estimation based on the energy of backscattered ultrasound [J].
Arthur, RM ;
Straube, WL ;
Starman, JD ;
Moros, EG .
MEDICAL PHYSICS, 2003, 30 (06) :1021-1029
[5]   A NOVEL METHOD FOR ANGLE INDEPENDENT ULTRASONIC-IMAGING OF BLOOD-FLOW AND TISSUE MOTION [J].
BOHS, LN ;
TRAHEY, GE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (03) :280-286
[6]   Magnetic resonance thermometry during hyperthermia for human high-grade sarcoma [J].
Carter, DL ;
MacFall, JR ;
Clegg, ST ;
Wan, X ;
Prescott, DM ;
Charles, HC ;
Samulski, TV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (04) :815-822
[7]   Lateral speckle tracking using synthetic lateral phase [J].
Chen, XC ;
Zohdy, MJ ;
Emelianov, SY ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (05) :540-550
[8]   Magnetic resonance temperature imaging [J].
De Senneville, BD ;
Quesson, B ;
Moonen, CTW .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2005, 21 (06) :515-531
[9]  
DEWHIRST MW, 1984, CANCER RES, V44, P43
[10]   Those in gene therapy should pay closer attention to lessons from hyperthermia [J].
Dewhirst, MW ;
Sneed, PK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (02) :597-599