Respective roles of scatter, attenuation, depth-dependent collimator response and finite spatial resolution in cardiac single-photon emission tomography quantitation:: a Monte Carlo study

被引:27
作者
El Fakhri, GN
Buvat, I
Pélégrini, M
Benali, H
Almeida, P
Bendriem, B
Todd-Pokropek, A
Di Paola, R
机构
[1] CHU Pitie Salpetriere, U494 INSERM, F-75634 Paris 13, France
[2] SHFJ, Grp Instrumentat PET SPET, F-91401 Orsay, France
关键词
quantitation; cardiac single-photon emission tomography Monte Carlo simulation;
D O I
10.1007/s002590050409
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to investigate the relative influence of scatter, attenuation, depth-dependent collimator response and finite spatial resolution upon the image characteristics in cardiac single-photon emission tomography (SPET). An acquisition of an anthropomorphic cardiac phantom was performed together with corresponding SPET Monte Carlo simulations. The cardiac phantom and the Monte Carlo simulations were designed so that the effect of scatter, attenuation, depth-dependent collimator response and finite spatial resolution could be studied individually and in combination. The impact of each physical effect and of combinations of effects was studied in terms of absolute and relative quantitative accuracy, spatial resolution and signal-to-noise ratio (SNR) in the resulting images. No corrections for these effects were assessed. Results obtained from Monte Carlo simulations and real acquisitions were in excellent agreement. Attenuation introduced about 90% activity underestimation in a 10-mm-thick left ventricle wall while finite spatial resolution alone introduced about 30% activity underestimation. Scatter had a negligible impact on quantitative accuracy in the recontructed slices when attenuation was present. Neither bull's eye map homogeneity nor contrast between a hot and a cold region were affected by depth-dependent collimator response or finite spatial resolution. Bull's eye map homogeneity was severely affected by attenuation but not by scatter. Attenuation and scatter reduced contrast by about 20% each. Both attenuation and scatter increased the full-width at half-maximum (FWHM) characterizing the spatial resolution of the imaging system by approximate to 1 mm each but the main effect responsible for the observed 11-mm FWHM spatial resolution was the depth-dependent collimator response. SNR was reduced by a factor of approximate to 2.5 because of attenuation, while scattered counts increased SNR by approximate to 10%. In conclusion, the quantification of the relative influence of the different physical effects showed that attenuation is definitely the major phenomenon affecting cardiac SPET imaging accuracy, but that finite spatial resolution, scatter and depth-dependent collimator response also contribute significantly to the errors in absolute and relative quantitation and to the poor spatial resolution.
引用
收藏
页码:437 / 446
页数:10
相关论文
共 31 条
  • [1] QUANTITATIVE SPECT BY ATTENUATION CORRECTION OF THE PROJECTION SET USING TRANSMISSION DATA - EVALUATION OF A METHOD
    ALMQUIST, H
    PALMER, J
    LJUNGBERG, M
    WOLLMER, P
    STRAND, SE
    JONSON, B
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1990, 16 (8-10): : 587 - 594
  • [2] BECK JW, 1982, IEEE T NUCL SCI, V29, P506, DOI 10.1109/TNS.1982.4335896
  • [3] A COMPARATIVE-STUDY OF SCATTER CORRECTION METHODS FOR SCINTIGRAPHIC IMAGES
    BONNIN, F
    BUVAT, I
    BENALI, H
    DIPAOLA, R
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1994, 21 (05): : 388 - 393
  • [4] Buvat I, 1997, J NUCL MED, V38, P324
  • [5] BUVAT I, 1995, J NUCL MED, V36, P1476
  • [6] ENERGY AND SPATIAL-DISTRIBUTION OF MULTIPLE ORDER COMPTON SCATTER IN SPECT - A MONTE-CARLO INVESTIGATION
    FLOYD, CE
    JASZCZAK, RJ
    HARRIS, CC
    COLEMAN, RE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (10) : 1217 - 1230
  • [7] COMPENSATION OF SPATIAL SYSTEM RESPONSE IN SPECT WITH CONJUGATE-GRADIENT RECONSTRUCTION TECHNIQUE
    FORMICONI, AR
    PUPI, A
    PASSERI, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (01) : 69 - 84
  • [8] MONTE-CARLO ANALYSIS OF CAMERA-INDUCED SPECTRAL CONTAMINATION FOR DIFFERENT PRIMARY ENERGIES
    GAGNON, D
    LAPERRIERE, L
    POULIOT, N
    DEVRIES, DJ
    MOORE, SC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (09) : 1725 - 1739
  • [9] EFFECTS OF MYOCARDIAL WALL THICKNESS ON SPECT QUANTIFICATION
    GALT, JR
    GARCIA, EV
    ROBBINS, WL
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (02) : 144 - 150
  • [10] Hutton BF, 1997, EUR J NUCL MED, V24, P797