Chirality and frequency measurement of longitudinal rolling of human sperm using optical trap

被引:6
|
作者
Zhong, Zhensheng [1 ]
Zhang, Can [1 ]
Liu, Rui [1 ]
He, Jun [1 ]
Yang, Han [1 ,2 ]
Cheng, Zijie [3 ]
Wang, Tao [1 ]
Shao, Meng [1 ]
Fang, Shu [1 ]
Zhang, Shengzhao [1 ]
Shi, Hui [1 ]
Xue, Rufeng [2 ]
Zou, Huijuan [2 ]
Ke, Zeyu [1 ]
Zhang, Zhiguo [1 ,2 ]
Zhou, Jinhua [1 ]
机构
[1] Anhui Med Univ, Anhui Prov Inst Translat Med, Sch Biomed Engn, Hefei, Peoples R China
[2] Anhui Med Univ, Reprod Med Ctr, Dept Obstet & Gynecol, Affiliated Hosp 1, Hefei, Peoples R China
[3] City Univ London, Sch Sci & Technol, London, England
基金
中国国家自然科学基金;
关键词
optical tweezers; sperm; longitudinal rolling; rolling chirality; rolling frequency; FORCE; MOTILITY; TRACKING; LIGHT;
D O I
10.3389/fbioe.2022.1028857
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Motility is one of the most critical features to evaluate sperm quality. As longitudinal rolling of human sperm has long been ignored until recently, its detailed dynamics and cellular biological mechanisms are still largely unknown. Here we report an optical-tweezers-based method to evaluate the chirality and frequency of sperm rotation. According to the intensity distribution patterns of off-focus micron-size particles, we established a method to judge the orientation of the sperm head along the optical axis in the optical trap. Together with the rotation direction of the projection of the sperm head, the chirality of longitudinal rolling of sperm can be measured without the application of three-dimensional tracking techniques or complex optical design. By video tracking optically trapped sperm cells from different patients, both rolling chirality and rolling frequency were analyzed. In this study, all the vertically trapped human sperm cells adopt a right-hand longitudinal rolling. The orientation and rolling frequency but not the rolling chirality of sperm in the optical trap are affected by the trap height. The rotation analysis method developed in this study may have clinical potential for sperm quality evaluation.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Wideband frequency response measurement using optical heterodyne technique
    Cai, Shidong
    Qiu, Jiheng
    Hongwai jishu, 1993, 15 (04): : 9 - 11
  • [32] Chromatic dispersion measurement using optical beating null frequency
    Abdul-Rashid, Hairul A.
    Gopinathan, Vinesh
    Mokhtar, Mohamad R.
    Yusoff, Zulfadzli
    Al-Qdah, Malik T.
    Rahman, Faidz A.
    OPTICAL ENGINEERING, 2008, 47 (02)
  • [33] The Direct Measurement of the Stepping Force of a Purified Vesicle using a Single Beam Optical Trap
    Raupp, Justin J.
    Sakamoto, Takeshi
    BIOPHYSICAL JOURNAL, 2020, 118 (03) : 435A - 435A
  • [34] The Measurement of the Stepping Force of Purified Zymogen Graunles using a Single Beam Optical Trap
    Raupp, Justin J.
    Mei, Yuwen
    Sakamoto, Takeshi
    BIOPHYSICAL JOURNAL, 2021, 120 (03) : 343A - 343A
  • [35] Direct measurement of local chromatin fluidity using optical trap modulation force spectroscopy
    Roopa, T.
    Shivashankar, G. V.
    BIOPHYSICAL JOURNAL, 2006, 91 (12) : 4632 - 4637
  • [36] Ultrahigh vacuum pressure measurement using magneto-optical trap on atom chip
    Supakar, S.
    Singh, Vivek
    Tiwari, V. B.
    Mishra, S. R.
    JOURNAL OF APPLIED PHYSICS, 2023, 134 (02)
  • [37] Wideband Doppler frequency shift measurement and direction ambiguity resolution using optical frequency shift and optical heterodyning
    Lu, Bing
    Pan, Wei
    Zou, Xihua
    Yan, Xianglei
    Yan, Lianshan
    Luo, Bin
    OPTICS LETTERS, 2015, 40 (10) : 2321 - 2324
  • [38] Determination of motility forces of human spermatozoa using an 800 nm optical trap
    Konig, K
    Svaasand, L
    Liu, YG
    Sonek, G
    Patrizio, P
    Tadir, Y
    Berns, MW
    Tromberg, BJ
    CELLULAR AND MOLECULAR BIOLOGY, 1996, 42 (04) : 501 - 509
  • [39] Simultaneous measurement of optical fibre nonlinearity and dispersion using frequency resolved optical gating
    Barry, LP
    Dudley, JM
    Bollond, PG
    Harvey, JD
    Leonhardt, R
    ELECTRONICS LETTERS, 1997, 33 (08) : 707 - 708
  • [40] SPATIAL-FREQUENCY MEASUREMENT USING AN ULTRASONIC-OPTICAL CORRELATOR
    MIYAGI, K
    NAKAGI, Y
    ELECTRICAL ENGINEERING IN JAPAN, 1978, 98 (06) : 113 - 120