Glucose Sensing Using Capacitive Biosensor Based on Polyvinylidene Fluoride Thin Film

被引:24
作者
Hartono, Ambran [1 ]
Sanjaya, Edi [1 ]
Ramli, Ramli [2 ]
机构
[1] UIN Syarif Hidayatullah Jakarta, Fac Sci & Technol, Dept Phys, Tangerang Selatan 15412, Banten, Indonesia
[2] Univ Negeri Padang, Fac Math & Nat Sci, Dept Phys, Padang 25131, Indonesia
来源
BIOSENSORS-BASEL | 2018年 / 8卷 / 01期
关键词
capacitive biosensor; glucose sensing; GOx enzyme; PVDF film; SPECTROSCOPY; ELECTRODE;
D O I
10.3390/bios8010012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A polyvinylidene fluoride (PVDF) film-based capacitive biosensor was developed for glucose sensing. This device consists of a PVDF film sandwiched between two electrodes. A capacitive biosensor measures the dielectric properties of the dielectric layers at the interface between the electrolyte and the electrode. A glucose oxidase (GOx) enzyme was immobilized onto the electrode to oxidize glucose. In practice, the biochemical reaction of glucose with the GOx enzyme generates free electron carriers. Consequently, the potential difference between the electrodes is increased, resulting in a measurable voltage output of the biosensor. The device was tested for various glucose concentrations in the range of 0.013 to 5.85 M, and various GOx enzyme concentrations between 4882.8 and 2.5 million units/L. We found that the sensor output increased with increasing glucose concentration up to 5.85 M. These results indicate that the PVDF film-based capacitive biosensors can be properly applied to glucose sensing and provide opportunities for the low-cost fabrication of glucose-based biosensors based on PVDF materials.
引用
收藏
页数:10
相关论文
共 20 条
[1]   Glucose oxidase - An overview [J].
Bankar, Sandip B. ;
Bule, Mahesh V. ;
Singhal, Rekha S. ;
Ananthanarayan, Laxmi .
BIOTECHNOLOGY ADVANCES, 2009, 27 (04) :489-501
[2]  
Berggren C, 2001, ELECTROANAL, V13, P173, DOI 10.1002/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO
[3]  
2-B
[4]   Glucose Sensing for Diabetes Monitoring: Recent Developments [J].
Bruen, Danielle ;
Delaney, Colm ;
Florea, Larisa ;
Diamond, Dermot .
SENSORS, 2017, 17 (08)
[5]   Capacitive detection of glucose using molecularly imprinted polymers [J].
Cheng, ZL ;
Wang, EK ;
Yang, XR .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (03) :179-185
[6]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[7]   Glucose oxidase immobilized on magnetic nanoparticles: Nanobiosensors for fluorescent glucose monitoring [J].
del Barrio, Melisa ;
Moros, Maria ;
Puertas, Sara ;
de la Fuente, Jesus M. ;
Grazu, Valeria ;
Cebolla, Vicente ;
de Marcos, Susana ;
Galban, Javier .
MICROCHIMICA ACTA, 2017, 184 (05) :1325-1333
[8]   Capacitive Biosensors and Molecularly Imprinted Electrodes [J].
Erturk, Gizem ;
Mattiasson, Bo .
SENSORS, 2017, 17 (02)
[9]   Depth-selective photothermal IR spectroscopy of skin: potential application for non-invasive glucose measurement [J].
Hertzberg, Otto ;
Bauer, Alexander ;
Kuederle, Arne ;
Pleitez, Miguel A. ;
Maentele, Werner .
ANALYST, 2017, 142 (03) :495-502
[10]   A Capacitive MEMS Viscometric Sensor for Affinity Detection of Glucose [J].
Huang, Xian ;
Li, Siqi ;
Schultz, Jerome ;
Wang, Qian ;
Lin, Qiao .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2009, 18 (06) :1246-1254