Development of Analytical Method for Detection of Some Pharmaceuticals in Surface Water

被引:21
作者
Al-Qaim, Fouad Fadhil [1 ,2 ]
Abdullah, Md Pauzi [1 ,3 ]
Othman, Mohamed Rozali [1 ,3 ]
Latip, Jalifah [1 ]
Afiq, Wan Mohamed [1 ]
机构
[1] Univ Kebangsaan UKM, Fac Sci & Technol, Sch Chem Sci & Food Technol, Bangi 43600, Selangor, Malaysia
[2] Babylon Univ, Fac Sci Women, Chem Dept, Hilla, Iraq
[3] Univ Kebangsaan UKM, Fac Sci & Technol, Ctr Water Res & Anal ALIR, Bangi 43600, Selangor, Malaysia
关键词
Diclofenac; Mefenamic acid; Electrospray Ionization; Mass spectrometry; Solid phase extraction (SPE); Tangkas river; Collision energy; LIQUID-CHROMATOGRAPHY; DRUG RESIDUES; MASS; PRODUCTS; SAMPLES; HPLC;
D O I
10.4314/tjpr.v12i4.25
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Purpose: To develop and validate a simple method using solid - phase extraction along with liquid chromatography-time of flight mass spectrometry for the analysis of pharmaceuticals in surface water of Tangkas River, Malaysia. Methods: Liquid chromatography (LC) was performed on a Dionex Ultimate 3000/LC 09115047 (USA) system equipped with a vacuum degasser, a quaternary pump, an autosampler and UV-Vis diod array detector. Chromatography was performed on a Thermo Scientific C18 (250 mm x 2.1 mm, i.d.: 5 mu m) column. The injection volume was 20 mu L. All compounds (hydrochlorothiazide, gliclazide, diclofenac-Na and mefenamic acid) were analysed in negative ion (NI) mode and eluted off the column with a mobile phase consisting of (A) 0.1% formic acid (FA) in deionised water (DIW) and (B) 40% acetonitrile (ACN) in methanol (MeOH) at 0.3 ml/min. Mass spectrometry was performed on a time of flight (TOF) instrument. Results: The linearity range, 5 - 500 ng/mL, provided a determination coefficient (R-2) > 0.99 for all compounds. The limit of detection (LOD) ranged from 65 - 136 ng/L while recovery ranged from 45 - 111.2 % in the river water. Two pharmaceutical compounds were detected in the surface water samples: diclofenac sodium and mefenamic acid at concentrations of 340 and 545 ng/L, respectively. Conclusion: The developed method is linear in the range 5 - 500 ng/mL, and precise and acceptable recoveries were obtained. In addition, this method is suitable to identify and quantify trace concentrations of diclofenac sodium and mefenamic acid in surface water.
引用
收藏
页码:609 / 616
页数:8
相关论文
共 19 条
[1]   Determination of drug residues in water by the combination of liquid chromatography or capillary electrophoresis with electrospray mass spectrometry [J].
Ahrer, W ;
Scherwenk, E ;
Buchberger, W .
JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (01) :69-78
[2]   Multi-residue analytical method for human pharmaceuticals and synthetic hormones in river water and sewage effluents by solid-phase extraction and liquid chromatography-tandem mass spectrometry [J].
Al-Odaini, Najat Ahmed ;
Zakaria, Mohamad Pauzi ;
Yaziz, Mohamad Ismail ;
Surif, Salmijah .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (44) :6791-6806
[3]  
Al-Qaim FF., 2012, INT J PHARM PHARM SC, V4, P3
[4]   Investigating the environmental transport of human pharmaceuticals to streams in the United Kingdom [J].
Ashton, D ;
Hilton, M ;
Thomas, KV .
SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 333 (1-3) :167-184
[5]  
Brijesh S, 2009, TROP J PHARM RES, V8, P539
[6]  
Carpinteiro J, 2004, J CHROMATOGR A, V1056, P179, DOI [10.1016/j.chroma.2004.06.111, 10.1016/S0021-9673(04)01082-9]
[7]   Winter accumulation of acidic pharmaceuticals in a Swedish river [J].
Daneshvar, Atlasi ;
Svanfelt, Jesper ;
Kronberg, Leif ;
Weyhenmeyer, Gesa A. .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2010, 17 (04) :908-916
[8]   Analysis of 100 pharmaceuticals and their degradates in water samples by liquid chromatography/quadrupole time-of-flight mass spectrometry [J].
Ferrer, Imma ;
Thurman, E. Michael .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1259 :148-157
[9]   Development of a multi-residue analytical methodology based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for screening and trace level determination of pharmaceuticals in surface and wastewaters [J].
Gros, Meritxell ;
Petrovic, Mira ;
Barcelo, Damia .
TALANTA, 2006, 70 (04) :678-690
[10]   The effect of signal suppression and mobile phase composition on the simultaneous analysis of multiple classes of acidic/neutral pharmaceuticals and personal care products in surface water by solid-phase extraction and ultra performance liquid chromatography-negative electrospray tandem mass spectrometry [J].
Kasprzyk-Hordern, Barbara ;
Dinsdale, Richard M. ;
Guwy, Alan J. .
TALANTA, 2008, 74 (05) :1299-1312