Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin

被引:194
|
作者
Malanda, Uriell L. [1 ]
Welschen, Laura M. C. [1 ]
Riphagen, Ingrid I. [2 ]
Dekker, Jacqueline M. [3 ,4 ]
Nijpels, Giel [1 ]
Bot, Sandra D. M. [1 ,3 ,4 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, EMGO Inst Hlth & Care Res, Dept Gen Practice, NL-1007 MB Amsterdam, Netherlands
[2] Norwegian Univ Sci & Technol, Fac Med, Unit Appl Clin Res, N-7034 Trondheim, Norway
[3] Vrije Univ Amsterdam, Med Ctr, EMGO Inst Hlth & Care Res, Dept Epidemiol, NL-1007 MB Amsterdam, Netherlands
[4] Vrije Univ Amsterdam, Med Ctr, EMGO Inst Hlth & Care Res, Dept Biostat, NL-1007 MB Amsterdam, Netherlands
来源
COCHRANE DATABASE OF SYSTEMATIC REVIEWS | 2012年 / 01期
关键词
Blood Glucose Self-Monitoring; Diabetes Mellitus Type 2 [blood; Hyperglycemia [prevention & control; Hypoglycemic Agents [administration & dosage; Insulin [administration & dosage; Randomized Controlled Trials as Topic; Humans; RANDOMIZED CONTROLLED-TRIAL; GLYCATED HEMOGLOBIN LEVELS; IMPROVED GLYCEMIC CONTROL; METABOLIC-CONTROL; TREATED PATIENTS; PARALLEL-GROUP; PRIMARY-CARE; IMPACT; MANAGEMENT; METAANALYSIS;
D O I
10.1002/14651858.CD005060.pub3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Self-monitoring of blood glucose (SMBG) has been found to be effective for patients with type 1 diabetes and for patients with type 2 diabetes using insulin. There is much debate on the effectiveness of SMBG as a tool in the self-management for patients with type 2 diabetes who are not using insulin. Objectives To assess the effects of SMBG in patients with type 2 diabetes mellitus who are not using insulin. Search methods Multiple electronic bibliographic and ongoing trial databases were searched supplemented with handsearches of references of retrieved articles (date of last search: 07 July 2011). Selection criteria Randomised controlled trials investigating the effects of SMBG compared with usual care, self-monitoring of urine glucose (SMUG) or both in patients with type 2 diabetes who where not using insulin. Studies that used glycosylated haemoglobin A1c (HbA1c) as primary outcome were eligible for inclusion. Data collection and analysis Two authors independently extracted data from included studies and evaluated the studies' risk of bias. Data from the studies were compared to decide whether they were sufficiently homogeneous to pool in a meta-analysis. Primary outcomes were HbA1c, healthrelated quality of life, well-being and patient satisfaction. Secondary outcomes were fasting plasma glucose level, hypoglycaemic episodes, morbidity, adverse effects and costs. Main results Twelve randomised controlled trials were included and evaluated outcomes in 3259 randomised patients. Intervention duration ranged from 6 months (26 weeks) to 12 months (52 weeks). Nine trials compared SMBG with usual care without monitoring, one study compared SMBG with SMUG, one study was a three-armed trial comparing SMBG and SMUG with usual care and one study was a three-armed trial comparing less intensive SMBG and more intensive SMBG with a control group. Seven out of 11 studies had a low risk of bias for most indicators. Meta-analysis of studies including patients with a diabetes duration of one year or more showed a statistically significant SMBG induced decrease in HbA1c at up to six months follow-up (-0.3; 95% confidence interval (CI)-0.4 to 0.1; 2324 participants, nine trials), yet an overall statistically non-significant SMBG induced decrease was seen at 12 month followup (-0.1; 95% CI-0.3 to 0.04; 493 participants, two trials). Qualitative analysis of the effect of SMBG on well-being and quality of life showed no effect on patient satisfaction, general well-being or general health-related quality of life. Two trials reported costs of self-monitoring: One trial compared the costs of self-monitoring of blood glucose with self-monitoring of urine glucose based on nine measurements per week and with the prices in US dollars for self-monitoring in 1990. Authors concluded that total costs in the first year of self-monitoring of blood glucose, with the purchase of a reflectance meter were 12 times more expensive than self-monitoring of urine glucose ($ 481 or 361 EURO [11/2011 conversion] versus $ 40 or 30 EURO [11/2011 conversion]). Another trial reported a full economical evaluation of the costs and effects of self-monitoring. At the end of the trial, costs for the intervention were 89 pound (104 EURO [11/2011 conversion]) for standardized usual care (control group), 181 pound (212 EURO [11/2011 conversion]) for the less intensive self-monitoring group and 173 pound (203 EURO [11/2011 conversion]) for the more intensive self-monitoring group. Higher losses to follow-up in the more intensive self-monitoring group were responsible for the difference in costs, compared to the less intensive selfmonitoring group. There were few data on the effects on other outcomes and these effects were not statistically significant. None of the studies reported data on morbidity. Authors' conclusions From this review, we conclude that when diabetes duration is over one year, the overall effect of self-monitoring of blood glucose on glycaemic control in patients with type 2 diabetes who are not using insulin is small up to six months after initiation and subsides after 12 months. Furthermore, based on a best-evidence synthesis, there is no evidence that SMBG affects patient satisfaction, general wellbeing or general health-related quality of life. More research is needed to explore the psychological impact of SMBG and its impact on diabetes specific quality of life and well-being, as well as the impact of SMBG on hypoglycaemia and diabetic complications.
引用
收藏
页数:89
相关论文
共 50 条
  • [21] Improvement of Glycosylated Hemoglobin in Patients with Type 2 Diabetes Mellitus under Insulin Treatment by Reimbursement for Self-Monitoring of Blood Glucose
    Song, Young Shin
    Koo, Bo Kyung
    Kim, Sang Wan
    Yi, Ka Hee
    Shin, Kichul
    Moon, Min Kyong
    DIABETES & METABOLISM JOURNAL, 2018, 42 (01) : 28 - 42
  • [22] Effectiveness for self-monitoring of blood sugar on blood glucose control in Turkish patients with type 2 diabetes mellitus
    Baltaci, Davut
    Kutlucan, Ali
    Ozturk, Serkan
    Saritas, Ayhan
    Celer, Ahmet
    Celbek, Gokhan
    Deler, Harun
    Aydin, Yusuf
    Ankarali, Handan
    MEDICINSKI GLASNIK, 2012, 9 (02) : 211 - 217
  • [23] RELATIONSHIP BETWEEN SELF-MONITORING OF BLOOD GLUCOSE AND TREATMENT PROGRESSION IN PATIENTS WITH TYPE 2 DIABETES MELLITUS
    Wade, R. L.
    Kindermann, S. L.
    Hou, Q.
    Dirani, R.
    VALUE IN HEALTH, 2013, 16 (03) : A175 - A175
  • [24] Association between self-monitoring of blood glucose and glycemic control in patients with type 2 diabetes mellitus
    Wen, L
    Parchman, ML
    Linn, WD
    Lee, S
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2004, 61 (22) : 2401 - 2405
  • [25] Self-monitoring of blood glucose in gestational diabetes mellitus
    Fontaine, P
    DIABETES & METABOLISM, 2003, 29 (02) : S37 - S41
  • [26] Self-monitoring of blood glucose for individuals with type 2 diabetes not using insulin: Leaving no cornerstone unturned
    Rabi, Doreen M.
    Johnson, Jeffery A.
    Edwards, Alun L.
    CANADIAN JOURNAL OF DIABETES, 2010, 34 (01) : 24 - 26
  • [27] Evaluation of blood glucose fluctuation in Japanese patients with type 1 diabetes mellitus by self-monitoring of blood glucose and continuous glucose monitoring
    Kusunoki, Yoshiki
    Katsuno, Tomoyuki
    Nakae, Rie
    Watanabe, Kahori
    Akagami, Takafumi
    Ochi, Fumihiro
    Tokuda, Masaru
    Murai, Kazuki
    Miuchi, Masayuki
    Miyagawa, Jun-ichiro
    Namba, Mitsuyoshi
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2015, 108 (02) : 342 - 349
  • [28] The effects of structured self-monitoring of blood glucose on therapeutic effectiveness and adherence in patients with type 2 diabetes mellitus initiating insulin treatment
    Suvorova, L. A.
    Petrov, A. V.
    Strongin, L. G.
    DIABETES MELLITUS, 2013, 16 (04): : 52 - 57
  • [29] Systematic Review of Self-Monitoring of Blood Glucose in Patients With Type 2 Diabetes
    Chircop, James
    Sheffield, David
    Kotera, Yasuhiro
    NURSING RESEARCH, 2021, 70 (06) : 487 - 497
  • [30] Compliance with recommended self-monitoring of blood glucose in patients with Type 1 diabetes mellitus.
    Shankar, A
    Conner, MT
    Bodansky, HJ
    DIABETOLOGIA, 2003, 46 : A90 - A90