Design of a Continuous Passive and Active Motion Device for Hand Rehabilitation

被引:9
作者
Birch, B. [1 ]
Haslam, E. [1 ]
Heerah, I. [1 ]
Dechev, N. [1 ]
Park, E. J. [1 ]
机构
[1] Univ Victoria, Dept Mech Engn, Victoria, BC V8W 3P6, Canada
来源
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8 | 2008年
关键词
D O I
10.1109/IEMBS.2008.4650162
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents the design of a novel, portable device for hand rehabilitation. The device provides for CPM (continuous passive motion) and CAM (continuous active motion) hand rehabilitation for patients recovering from damage such as flexor tendon repair and strokes. The device is capable of flexing/extending the MCP (metacarpophalangeal) and PIP (proximal interphalangeal) joints through a range of motion of 0 to 90 for both the joints independently. In this way, typical hand rehabilitation motions such as intrinsic plus, intrinsic minus, and a fist can be achieved without the need of any splints or attachments. The CPM mode is broken into two subgroups. The first mode is the use of preset waypoints for the device to cycle through. The second mode involves motion from a starting position to a final position, but senses the torque from the user during the cycle. Therefore the user can control the ROM by resisting when they are at the end of the desired motion. During the CPM modes the device utilizes a minimum jerk trajectory model under PD control, moving smoothly and accurately between preselected positions. CAM is the final mode where the device will actively resist the movement of the user. The user moves from a start to end position while the device produces a torque to resist the motion. This active resistance motion is a unique ability designed to mimic the benefits of a human therapist. Another unique feature of the device is its ability to independently act on both the MCP and PIP joints. The feedback sensing built into the device makes it capable of offering a wide and flexible range of rehabilitation programs for the hand.
引用
收藏
页码:4306 / 4309
页数:4
相关论文
共 14 条
  • [1] A comparison of 2 continuous passive motion protocols after total knee arthroplasty - A controlled and randomized study
    Bennett, LA
    Brearley, SC
    Hart, JAL
    Bailey, MJ
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (02) : 225 - 233
  • [2] The Rutgers Master II - New design force-feedback glove
    Bouzit, M
    Burdea, G
    Popescu, G
    Boian, R
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2002, 7 (02) : 256 - 263
  • [3] Early controlled passive motion improves early fracture alignment and structural properties in a closed extra-articular metacarpal fracture in a rabbit model
    Feehan, Lynne M.
    Tang, Cecilia S.
    Oxland, Thomas R.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (02): : 200 - 208
  • [4] Fu YL, 2005, P ANN INT IEEE EMBS, P5017
  • [5] Fuxiang Z, 2007, REHABILITATION ROBOT, P579
  • [6] A torque-controlled device to measure passive abduction of the thumb carpometacarpal joint
    Harvey, Lisa
    de Jong, Inge
    Goehl, Gerlinde
    Armstrong, Belinda
    Allaous, Jeanine
    [J]. JOURNAL OF HAND THERAPY, 2006, 19 (04) : 403 - 408
  • [7] HO H, 2006, P 1 INT C INN COMP I, V2, P146
  • [8] HOGAN N, 1984, J NEUROSCI, V4, P2745
  • [9] O'Driscoll SW, 2000, J REHABIL RES DEV, V37, P179
  • [10] Immediate active mobilization versus immobilization for opposition tendon transfer in the hand
    Rath, Santosh
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (05): : 754 - 759