Comparison Between Magnetic Anchoring and Guidance System Camera-Assisted Laparoendoscopic Single-Site Surgery Nephrectomy and Conventional Laparoendoscopic Single-Site Surgery Nephrectomy in a Porcine Model: Focus on Ergonomics and Workload Profiles

被引:11
作者
Han, Woong Kyu [1 ,2 ]
Tan, Yung K. [1 ]
Olweny, Ephrem O. [1 ]
Yin, Gang [1 ]
Liu, Zhuo-Wei [1 ]
Faddegon, Stephen [1 ]
Scott, Daniel J. [3 ]
Cadeddu, Jeffrey A. [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Urol, Dallas, TX 75390 USA
[2] Yonsei Univ, Coll Med, Dept Urol, Urol Sci Inst, Seoul, South Korea
[3] Univ Texas SW Med Ctr Dallas, Dept Surg, Dallas, TX 75390 USA
关键词
LAPAROSCOPIC NEPHRECTOMY; INTRAABDOMINAL CAMERA; INSTRUMENTATION; INCISION;
D O I
10.1089/end.2012.0484
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To compare surgeon-assessed ergonomic and workload demands of magnetic anchoring and guidance system (MAGS) laparoendoscopic single-site surgery (LESS) nephrectomy with conventional LESS nephrectomy in a porcine model. Methods: Participants included two expert and five novice surgeons who each performed bilateral LESS nephrectomy in two nonsurvival animals using either the MAGS camera or conventional laparoscope. Task difficulty and workload demands of the surgeon and camera driver were assessed using the validated National Aeronautics and Space Administration Task Load Index (NASA-TLX) questionnaire. Surgeons were also asked to score 6 parameters on a Likert scale (range 1 = low/easy to 5 = high/hard): procedure-associated workload, ergonomics, technical challenge, visualization, accidental events, and instrument handling. Each step of the nephrectomy was also timed and instrument clashing was quantified. Results: Scores for each parameter on the Likert scale were significantly lower for MAGS-LESS nephrectomy. Mean number of internal and external clashes were significantly lower for the MAGS camera (p < 0.001). Mean task times for each procedure were shorter for experts than for novices, but this was not statistically significant. NASA-TLX workload ratings by the surgeon and camera driver showed that MAGS resulted in a significantly lower workload than the conventional laparoscope during LESS nephrectomy (p < 0.05). Conclusions: The use of the MAGS camera during LESS nephrectomy lowers the task workload for both the surgeon and camera driver when compared to conventional laparoscope use. Subjectively, it appears to also improve surgeons' impressions of ergonomics and technical challenge. Pending approval for clinical use, further evaluation in the clinical setting is warranted.
引用
收藏
页码:490 / 496
页数:7
相关论文
共 21 条
[1]   A randomized comparison of laparoscopic, magnetically anchored, and flexible endoscopic cameras in performance and workload between laparoscopic and single-incision surgery [J].
Arain, Nabeel A. ;
Cadeddu, Jeffrey A. ;
Best, Sara L. ;
Roshek, Thomas ;
Chang, Victoria ;
Hogg, Deborah C. ;
Bergs, Richard ;
Fernandez, Raul ;
Webb, Erin M. ;
Scott, Daniel J. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (04) :1170-1180
[2]   Solo Surgeon Laparo-Endoscopic Single Site Nephrectomy Facilitated by New Generation Magnetically Anchored and Guided Systems Camera [J].
Best, Sara L. ;
Bergs, Richard ;
Scott, Daniel J. ;
Fernandez, Raul ;
Mashaud, Lauren B. ;
Cadeddu, Jeffrey A. .
JOURNAL OF ENDOUROLOGY, 2012, 26 (03) :214-218
[3]   Magnetic Anchoring and Guidance System Instrumentation for Laparo-endoscopic Single-site Surgery/Natural Orifice Transluminal Endoscopic Surgery: Lack of Histologic Damage After Prolonged Magnetic Coupling Across the Abdominal Wall [J].
Best, Sara L. ;
Kabbani, Wareef ;
Scott, Daniel J. ;
Bergs, Richard ;
Beardsley, Heather ;
Fernandez, Raul ;
Mashaud, Lauren B. ;
Cadeddu, Jeffrey A. .
UROLOGY, 2011, 77 (01) :243-247
[4]   Maximizing coupling strength of magnetically anchored surgical instruments: how thick can we go? [J].
Best, Sara L. ;
Bergs, Richard ;
Gedeon, Makram ;
Paramo, Juan ;
Fernandez, Raul ;
Cadeddu, Jeffrey A. ;
Scott, Daniel J. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (01) :153-159
[5]   Novel magnetically guided intra-abdominal camera to facilitate laparoendoscopic single-site surgery: initial human experience [J].
Cadeddu, Jeffrey ;
Fernandez, Raul ;
Desai, Mihir ;
Bergs, Richard ;
Tracy, Chad ;
Tang, Shou-Jiang ;
Rao, Prashanth ;
Desai, Mahesh ;
Scott, Daniel .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2009, 23 (08) :1894-1899
[6]   NASA TLX: Software for assessing subjective mental workload [J].
Cao, Alex ;
Chintamani, Keshav K. ;
Pandya, Abhilash K. ;
Ellis, R. Darin .
BEHAVIOR RESEARCH METHODS, 2009, 41 (01) :113-117
[7]   Retraction and triangulation with neodymium magnetic forceps for single-port laparoscopic cholecystectomy [J].
Dominguez, Guillermo ;
Durand, Luis ;
De Rosa, Julian ;
Danguise, Eduardo ;
Arozamena, Carlos ;
Ferraina, Pedro A. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2009, 23 (07) :1660-1666
[8]  
HART S G, 1988, P139
[9]   Initial Experience With 50 Laparoendoscopic Single Site Surgeries Using a Homemade, Single Port Device at a Single Center [J].
Jeon, Hwang Gyun ;
Jeong, Wooju ;
Oh, Cheol Kyu ;
Lorenzo, Enrique Ian S. ;
Ham, Won Sik ;
Rha, Koon Ho ;
Han, Woong Kyu .
JOURNAL OF UROLOGY, 2010, 183 (05) :1866-1871
[10]  
Kaouk JH, 2011, EUR UROL, V60, P998, DOI [10.1016/j.eururo.2011.06.002, 10.1590/S1677-55382011000500017]