A simple on-line arterial time-activity curve detector for [O-15]water PET studies

被引:3
作者
Wollenweber, SD
Hichwa, RD
Ponto, LLB
机构
[1] P.E.T. Imaging Center, University of Iowa Hospitals and Clinics, Iowa City
关键词
D O I
10.1109/23.597022
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A simple, automated on-line detector system has been fabricated and implemented to detect the arterial time-activity curve (TAC) for bolus-injection [O-15]water PET studies. This system offers two significant improvements over existing systems: a pump mechanism is not required to control arterial blood flow through the detector and dispersion correction cg the time-activity curve for dispersion in external tubing is unnecessary. The [O-15] positrons emanating from blood within a thin-walled, 0.134 cm inner-diameter plastic tube are detected by a 0.5 cm wide by 1.0 cm long by 0.1 cm thick plastic scintillator mounted to a miniature PMT. Photon background is reduced to insignificant levels by a 2.0 cm thick cylindrical lead shield. Mean cerebral blood now (mCBF) determined from an autoradiographic model and from the TAC measured by 1-second automated sampling was compared to that calculated from a TAC acquired using 5-second integrated manual samples. Improvements in timing resolution (1-sec vs. 5-sec) cause small but significant differences between the two sampling methods. Dispersion is minimized due to small tubing diameters, short lengths of tubing between the radial arterial sampling site and the detector and the presence of a 3-way valve 10 cm proximal to the detector.
引用
收藏
页码:1417 / 1419
页数:3
相关论文
共 12 条
[1]   AUTOMATED BLOOD-SAMPLING SYSTEMS FOR POSITRON EMISSION TOMOGRAPHY [J].
ERIKSSON, L ;
HOLTE, S ;
BOHM, C ;
KESSELBERG, M ;
HOVANDER, B .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :703-707
[2]  
ERIKSSON L, 1991, MED PROG TECHNOL, V17, P249
[3]  
HERSCOVITCH P, 1983, J NUCL MED, V24, P782
[4]   A CONTINUOUS-FLOW INPUT FUNCTION DETECTOR FOR H-2 O-15 BLOOD-FLOW STUDIES IN POSITRON EMISSION TOMOGRAPHY [J].
HUTCHINS, GD ;
HICHWA, RD ;
KOEPPE, RA .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :546-549
[5]   ERROR ANALYSIS OF A QUANTITATIVE CEREBRAL BLOOD-FLOW MEASUREMENT USING (H2O)-O-15 AUTORADIOGRAPHY AND POSITRON EMISSION TOMOGRAPHY, WITH RESPECT TO THE DISPERSION OF THE INPUT FUNCTION [J].
IIDA, H ;
KANNO, I ;
MIURA, S ;
MURAKAMI, M ;
TAKAHASHI, K ;
UEMURA, K .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (05) :536-545
[6]   A SYSTEM FOR CEREBRAL BLOOD-FLOW MEASUREMENT USING AN (H2O)-O-15 AUTORADIOGRAPHIC METHOD AND POSITRON EMISSION TOMOGRAPHY [J].
KANNO, I ;
IIDA, H ;
MIURA, S ;
MURAKAMI, M ;
TAKAHASHI, K ;
SASAKI, H ;
INUGAMI, A ;
SHISHIDO, F ;
UEMURA, K .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1987, 7 (02) :143-153
[7]  
MEYER E, 1989, J NUCL MED, V30, P1069
[8]  
NELSON A D, 1990, American Journal of Physiologic Imaging, V5, P84
[9]  
RAICHLE ME, 1983, J NUCL MED, V24, P790
[10]   NONINVASIVE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW CHANGE WITH (H2O)-O-15 AND POSITRON EMISSION TOMOGRAPHY USING A MECHANICAL INJECTOR AND A STANDARD ARTERIAL INPUT FUNCTION [J].
SADATO, N ;
YONEKURA, Y ;
SENDA, M ;
MAGATA, Y ;
IWASAKI, Y ;
MATOBA, N ;
TSUCHIDA, T ;
TAMAKI, N ;
FUKUYAMA, H ;
SHIBASAKI, H ;
KONISHI, J .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) :703-710