Retrofit of distillation columns using thermodynamic analysis

被引:26
作者
Demirel, Y [1 ]
机构
[1] Virginia Polytech Inst & State Univ, Dept Chem Engn, Blacksburg, VA 24061 USA
关键词
thermodynamic analysis; column grand composite curves; exergy loss; retrofitting; thermodynamic efficiency;
D O I
10.1080/01496390600600047
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Thermodynamic analysis provides the column grand composite curves and exergy loss profiles, which are becoming readily available for a converged distillation column simulation. For example, the Aspen Plus simulator performs the thermodynamic analysis through its Column-Targeting tool for rigorous column calculations. This study uses the column grand composite curves and the exergy loss profiles obtained from Aspen Plus to assess the performance of the existing distillation columns, and reduce the costs of operation by appropriate retrofits in a methanol plant. Effectiveness of the retrofits is also assessed by means of thermodynamics and economics. The methanol plant utilizes two distillation columns to purify the methanol in its separation Section. The first column operates with 51 stages, has a side heat stream to the last stage, a partial condenser at the top and a side condenser at stage 2, and no reboiler. The second column operates with 95 stages, has a side heat stream to stage 95, a total condenser, and high reflux ratio. Despite the heat integration of the columns with the other Sections and a side condenser in column 1, the assessment of converged base case simulations have indicated the need for more profitable operations, and the required retrofits are suggested. For the first column, the retrofits consisting of a feed preheating and a second side condenser at stage 4 have reduced the total exergy loss by 21.5%. For the second column, the retrofits of two side reboilers at stages 87 and 92 have reduced the total exergy loss by 41.3%. After the retrofits, the thermodynamic efficiency has increased to 55.4% from 50.6% for the first column, while it has increased to 6.7% from 4.0% for the second. The suggested retrofits have reduced the exergy losses and hence the cost of energy considerably, and proved to be more profitable despite the fixed capital costs of retrofits for the distillation columns of the methanol plant.
引用
收藏
页码:791 / 817
页数:27
相关论文
共 19 条
[1]   Efficient use of an intermediate reboiler or condenser in a binary distillation [J].
Agrawal, R ;
Herron, DM .
AICHE JOURNAL, 1998, 44 (06) :1303-1315
[2]   Thermodynamic analysis of crude oil distillation systems [J].
Al-Muslim, H ;
Dincer, I .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2005, 29 (07) :637-655
[3]   Exergy analysis of single- and two-stage crude oil distillation units [J].
Al-Muslim, H ;
Dincer, I ;
Zubair, SM .
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2003, 125 (03) :199-207
[4]   Effect of feed on optimal thermodynamic performance of a distillation column [J].
Bandyopadhyay, S .
CHEMICAL ENGINEERING JOURNAL, 2002, 88 (1-3) :175-186
[5]   Temperature-enthalpy curve for energy targeting of distillation columns [J].
Bandyopadhyay, S ;
Malik, RK ;
Shenoy, UV .
COMPUTERS & CHEMICAL ENGINEERING, 1998, 22 (12) :1733-1744
[6]   A new exergy method for process analysis and optimization [J].
Chang, H ;
Li, JW .
CHEMICAL ENGINEERING SCIENCE, 2005, 60 (10) :2771-2784
[7]   Entropy production and exergy loss in experimental distillation columns [J].
de Koeijer, G ;
Rivero, R .
CHEMICAL ENGINEERING SCIENCE, 2003, 58 (08) :1587-1597
[8]   Thermodynamic analysis of separation systems [J].
Demirel, Y .
SEPARATION SCIENCE AND TECHNOLOGY, 2004, 39 (16) :3897-3942
[9]   Linear-nonequilibrium thermodynamics theory for coupled heat and mass transport [J].
Demirel, Y ;
Sandler, SI .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (13) :2439-2451
[10]  
DEMIREL Y, 2002, NONEQUILIBRIUM THERM