EVALUATION OF CANINE PROSTATE INTRAFRACTIONAL MOTION USING SERIAL CONE BEAM COMPUTED TOMOGRAPHY IMAGING

被引:12
作者
Harmon, Joseph, Jr. [1 ]
Yoshikawa, Hiroto [2 ]
Custis, James [2 ]
LaRue, Susan [2 ]
机构
[1] Richmond Radiat Oncol Ctr, Bon Secours Canc Inst, Henrico, VA 23230 USA
[2] Colorado State Univ, Coll Vet Med & Biomed Sci, Dept Environm & Radiol Hlth Sci, Ft Collins, CO 80523 USA
关键词
canine; CBCT; intrafractional; prostate; radiation therapy; rectal balloon; SBRT; translational; RADIATION-THERAPY; RECTAL BALLOON; CANCER; RADIOTHERAPY; SUPINE; PRONE; IMRT;
D O I
10.1111/j.1740-8261.2012.01986.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
This study used kilovoltage (kV) cone beam computed tomography (CBCT) imaging to characterize canine intrafractional prostate motion during hypofractionated stereotactic radiotherapy treatment. Serial CBCT images taken just prior to initiating treatment, and at several times during the treatment session, were acquired throughout the course of treatment for canine patients. All patients were immobilized in dorsal recumbency while using an air-inflated rectal balloon. For each treatment session, rigid registration of intrafraction CBCT images with the interfraction CBCT used for setup verification was performed. Contours of the prostate and urethra were drawn on each CBCT image set and the center of mass for each structure was evaluated as a function of time. A total of seven canine patients was included in the study, resulting in 41 CBCT images collected during a total of 12 treatment sessions. Over 70% of our data were collected for CBCTs taken between 20 and 51 min after final patient setup was complete. The mean intrafraction movement in a single direction for the prostate and urethra was =0.14 mm and =0.22 mm, respectively. The maximum intrafraction movement for the prostate and urethra was = 1.60 mm and = 2.00 mm, respectively. The maximum variability in intrafraction movement for the prostate and urethra, as defined by two standard deviations, was =1.40 mm and =1.50 mm, respectively. Minimal intrafraction variability using appropriate patient positioning and rectal balloon, combined with kV CBCT image-guided radiation therapy tools to account for interfraction changes, permit accurate and precise targeting of structures of interest.
引用
收藏
页码:93 / 98
页数:6
相关论文
共 27 条
[1]   DOSIMETRIC EFFECT OF INTRAFRACTION MOTION AND RESIDUAL SETUP ERROR FOR HYPOFRACTIONATED PROSTATE INTENSITY-MODULATED RADIOTHERAPY WITH ONLINE CONE BEAM COMPUTED TOMOGRAPHY IMAGE GUIDANCE [J].
Adamson, Justus ;
Wu, Qiuwen ;
Yan, Di .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (02) :453-461
[2]   PROSTATE INTRAFRACTION MOTION ASSESSED BY SIMULTANEOUS KILOVOLTAGE FLUOROSCOPY AT MEGAVOLTAGE DELIVERY I CLINICAL OBSERVATIONS AND PATTERN ANALYSIS [J].
Adamson, Justus ;
Wu, Qiuwen .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (05) :1563-1570
[3]   INFERENCES ABOUT PROSTATE INTRAFRACTION MOTION FROM PRE- AND POSTTREATMENT VOLUMETRIC IMAGING [J].
Adamson, Justus ;
Wu, Qiuwen .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (01) :260-267
[4]  
[Anonymous], 50 ICRU S
[5]  
Both S, 2010, INT J RADIAT ONCOL, V81, P1
[6]   Intrafractional prostate motion during online image guided intensity-modulated radiotherapy for prostate cancer [J].
Budiharto, Tom ;
Slagmolen, Pieter ;
Haustermans, Karin ;
Maes, Frederik ;
Junius, Sara ;
Verstraete, Jan ;
Oyen, Raymond ;
Hermans, Jeroen ;
Van den Heuvel, Frank .
RADIOTHERAPY AND ONCOLOGY, 2011, 98 (02) :181-186
[7]   Positional Reproducibility and Effects of a Rectal Balloon in Prostate Cancer Radiotherapy [J].
Cho, Jae Ho ;
Lee, Chang-Geol ;
Kang, Dae Ryong ;
Kim, Jooho ;
Lee, Sangkyu ;
Suh, Chang-Ok ;
Seong, Jinsil ;
Suh, Yang Gun ;
Lee, Ikjae ;
Kim, Gwi Eon .
JOURNAL OF KOREAN MEDICAL SCIENCE, 2009, 24 (05) :894-903
[8]   Intrafraction prostate motion during IMRT for prostate cancer [J].
Huang, E ;
Dong, L ;
Chandra, A ;
Kuban, DA ;
Rosen, II ;
Evans, A ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (02) :261-268
[9]   MINIMAL BENEFIT OF AN ENDORECTAL BALLOON FOR PROSTATE IMMOBILIZATION AS VERIFIED BY DAILY LOCALIZATION [J].
Hung, Arthur Y. ;
Garzotto, Mark ;
Kaurin, Darryl .
MEDICAL DOSIMETRY, 2011, 36 (02) :195-199
[10]   Radiotherapy of mobile tumors [J].
Jiang, Steve B. .
SEMINARS IN RADIATION ONCOLOGY, 2006, 16 (04) :239-248