Iodine Concentration and Optimization in Computed Tomography Angiography Current Issues

被引:55
作者
Faggioni, Lorenzo [1 ]
Gabelloni, Michela [1 ]
机构
[1] Univ Pisa, Dept Diagnost & Intervent Radiol, Via Paradisa 2, I-56100 Pisa, Italy
关键词
iodinated contrast medium; iodine concentration; CT angiography; iodine delivery rate; viscosity; signal-to-noise ratio; contrast-to-noise ratio; protocol optimization; CORONARY CT ANGIOGRAPHY; CONCENTRATION CONTRAST-MEDIUM; ARTERIAL OCCLUSIVE DISEASE; DUAL-SOURCE CT; IMAGE-QUALITY; ITERATIVE RECONSTRUCTION; MDCT ANGIOGRAPHY; MULTIDETECTOR CT; INTRAVASCULAR ENHANCEMENT; INITIAL-EXPERIENCE;
D O I
10.1097/RLI.0000000000000283
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computed tomography (CT) technology has seen a dramatic evolution in the recent past that has deeply changed the face of this diagnostic modality. Since the early days of helical single-slice and then multislice CT, CT angiography (CTA) has been one of the most technically demanding applications, both in terms of scanning technique and contrast medium (CM) injection protocol, due to the need to acquire a large amount of high-resolution data over a limited period corresponding to the peak contrast enhancement of the arterial system. Iodine concentration is one of the main determinants of arterial enhancement in CTA, and current low-osmolar and iso-osmolar nonionic CM for intravascular administration still come in a handful of molecules, but a relatively wide range of different iodine concentrations. This gives the opportunity to optimize CTA protocols as a function of several factors such as patient characteristics, CT technology, and CM features in an attempt to maximize the diagnostic yield of CTA examinations while considering patient safety and avoiding unnecessary extra costs. Our aim is to provide an up-to-date overview of the existing evidence on how changing iodine concentration can have an impact on CTA performance, especially with the use of state-of-the-art CT and power injector technology, in the perspective of improving patient care while minimizing overall exposure to iodinated CM and ionizing radiation.
引用
收藏
页码:816 / 822
页数:7
相关论文
共 54 条
[1]  
[Anonymous], ESUR GUID CONTR MED
[2]   Scan and contrast administration principles of MDCT [J].
Bae, KT ;
Heiken, JP .
EUROPEAN RADIOLOGY, 2005, 15 :E46-E59
[3]   Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches [J].
Bae, Kyongtae T. .
RADIOLOGY, 2010, 256 (01) :32-61
[4]  
Baert AL, 2009, MULTISLICE CT
[5]   Intraindividual comparison of contrast media concentrations for combined abdominal and thoracic MDCT [J].
Behrendt, Florian F. ;
Mahnken, Andreas H. ;
Stanzel, Sven ;
Seidensticker, Peter ;
Jost, Edgar ;
Guenther, Rolf W. ;
Muehlenbruch, Georg .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) :145-150
[6]   Identification of the Iodine Concentration That Yields the Highest Intravascular Enhancement in MDCT Angiography [J].
Behrendt, Florian F. ;
Pietsch, Hubertus ;
Jost, Gregor ;
Palmowski, Moritz ;
Guenther, Rolf W. ;
Mahnken, Andreas H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) :1151-1156
[7]   Intra-individual comparison of different contrast media concentrations (300 mg, 370 mg and 400 mg iodine) in MDCT [J].
Behrendt, Florian F. ;
Pietsch, Hubertus ;
Jost, Gregor ;
Sieber, Martin A. ;
Keil, Sebastian ;
Plumhans, Cedric ;
Seidensticker, Peter ;
Guenther, Rolf W. ;
Mahnken, Andreas H. .
EUROPEAN RADIOLOGY, 2010, 20 (07) :1644-1650
[8]   Parameters affecting bolus geometry in CTA: A review [J].
Cademartiri, F ;
van der Lugt, A ;
Luccichenti, G ;
Pavone, P ;
Krestin, GP .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (04) :598-607
[9]   Intravenous contrast material administration at helical 16-detector row CT coronary angiography: Effect of iodine concentration on vascular attenuation [J].
Cademartiri, F ;
Mollet, NR ;
van der Lugt, A ;
McFadden, EP ;
Stijnen, T ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2005, 236 (02) :661-665
[10]   CT-angiography protocol with low dose radiation and low volume contrast medium for non-cardiac chest pain [J].
Cakmakci, Emin ;
Ozkurt, Huseyin ;
Tokgoz, Safiye ;
Karabay, Esra ;
Ucan, Berna ;
Akdogan, Melek Pala ;
Basak, Muzaffer .
QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2014, 4 (05) :307-312