Evaluation of fit of cement-retained implant-supported 3-unit structures fabricated with direct metal laser sintering and vacuum casting techniques

被引:21
作者
Castillo Oyaguee, Raquel [1 ]
Sanchez-Turrion, Andres [1 ]
Francisco Lopez-Lozano, Jose [1 ]
Montero, Javier [2 ]
Albaladejo, Alberto [2 ]
Jesus Suarez-Garcia, Maria [1 ]
机构
[1] Complutense Univ Madrid UCM, Dept Buccofacial Prostheses, Fac Odontol, Madrid 28040, Spain
[2] Univ Salamanca USAL, Dept Surg, Fac Med, Salamanca 37007, Spain
关键词
Cement-retained implant-supported prostheses; Direct metal laser sintering; Vacuum casting; INTERNAL FIT; ALLOYS; CROWNS;
D O I
10.1007/s10266-011-0050-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated the vertical discrepancy of implant-fixed 3-unit structures. Frameworks were constructed with laser-sintered Co-Cr, and vacuum-cast Co-Cr, Ni-Cr-Ti, and Pd-Au. Samples of each alloy group were randomly luted in standard fashion using resin-modified glass-ionomer, self-adhesive, and acrylic/urethane-based cements (n = 12 each). Discrepancies were SEM analyzed. Three-way ANOVA and Student-Newman-Keuls tests were run (P < 0.05). Laser-sintered structures achieved the best fit per cement tested. Within each alloy group, resin-modified glass-ionomer and acrylic/urethane-based cements produced comparably lower discrepancies than the self-adhesive agent. The abutment position did not yield significant differences. All misfit values could be considered clinically acceptable.
引用
收藏
页码:249 / 253
页数:5
相关论文
共 15 条
[1]   Comparison of the bond strength of laser-sintered and cast base metal dental alloys to porcelain [J].
Akova, Tolga ;
Ucar, Yurdanur ;
Tukay, Alper ;
Balkaya, Mehmet Cudi ;
Brantley, William A. .
DENTAL MATERIALS, 2008, 24 (10) :1400-1404
[2]  
[Anonymous], QUINTESSENCE INT
[3]  
Anusavice K. J., 2003, PHILLIPSSCIENCE DENT, V11th
[4]   In vitro vertical misfit evaluation of cast frameworks for cement-retained implant-supported partial prostheses [J].
Castillo Oyaguee, Raquel ;
Sanchez Turrion, Andres ;
Toledano, Manuel ;
Monticelli, Francesca ;
Osorio, Raquel .
JOURNAL OF DENTISTRY, 2009, 37 (01) :52-58
[5]   A COMPARISION OF THE MARGINAL VERTICAL DISCREPANCIES OF ZIRCONIUM AND METAL CERAMIC POSTERIOR FIXED DENTAL PROSTHESES BEFORE AND AFTER CEMENTATION [J].
Gonzalo, Esther ;
Suarez, Maria J. ;
Serrano, Benjamin ;
Lozano, Jose F. L. .
JOURNAL OF PROSTHETIC DENTISTRY, 2009, 102 (06) :378-384
[6]  
JEMT T, 1991, International Journal of Oral and Maxillofacial Implants, V6, P270
[7]  
Michalakis KX, 2003, INT J ORAL MAX IMPL, V18, P719
[8]   PROPERTIES OF COBALT-CHROMIUM METAL CERAMIC ALLOYS AFTER HEAT-TREATMENT [J].
MORRIS, HF .
JOURNAL OF PROSTHETIC DENTISTRY, 1990, 63 (04) :426-433
[9]   The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: A comparative in vitro study [J].
Ortorp, Anders ;
Jonsson, David ;
Mouhsen, Alaa ;
von Steyern, Per Vult .
DENTAL MATERIALS, 2011, 27 (04) :356-363
[10]   Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology [J].
Quante, Katrin ;
Ludwig, Klaus ;
Kern, Matthias .
DENTAL MATERIALS, 2008, 24 (10) :1311-1315