Diagnostic value of coronary CT angiography with prospective ECG-gating in the diagnosis of coronary artery disease: a systematic review and meta-analysis

被引:43
作者
Sun, Zhonghua [1 ]
Ng, Kwan-Hoong [2 ]
机构
[1] Curtin Univ Technol, Perth, WA, Australia
[2] Univ Malaya, Kuala Lumpur, Malaysia
关键词
Coronary artery disease; Image quality; Coronary CT angiography; Prospective ECG-gating; Radiation dose; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; RADIATION-DOSE-REDUCTION; DUAL-SOURCE CT; IMAGE QUALITY; HIGH-PITCH; ACCURACY; EXPOSURE; PERFORMANCE; PROTOCOL;
D O I
10.1007/s10554-011-0006-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To perform a systematic review and meta-analysis of the diagnostic value of prospective ECG-gating coronary CT angiography in the diagnosis of coronary artery disease. A search of biomedical databases for English literature was performed to identify studies investigating the diagnostic value of 64- or more slice CT angiography with use of prospective ECG-gating in the diagnosis of coronary artery disease. Sensitivity, specificity, positive and negative predictive value estimates pooled across studies were tested using a fixed effects model. Fourteen studies met selection criteria for inclusion in the analysis. Pooled estimates and 95% confidence interval (CI) of sensitivity, specificity, positive and negative predictive value of prospective ECG-gating coronary CT angiography for diagnosis of significant coronary stenosis were 99% (95% CI: 98, 100%), 91% (95% CI: 88, 94%), 94% (95% CI: 91, 96%) and 99% (95% CI: 97, 100%), according to the patient-based assessment. The mean values of sensitivity, specificity, positive and negative predictive value of prospective ECG-gating coronary CT angiography were 95% (95% CI: 93, 96%), 95% (95% CI: 93, 95%), 88% (95% CI: 86, 90%), and 98% (95% CI: 97, 98%), according to vessel-based assessment; 92% (95% CI: 90, 93%), 97% (95% CI: 97, 98%), 84% (95% CI: 82, 86%), 99% (95% CI: 99, 99%), according to segment-based assessment, respectively. The mean effective dose was 3.3 mSv (95% CI: 2.3, 4.1 mSv) for the prospective ECG-gating coronary CT angiography. This analysis shows that for a predominantly male population with a high disease prevalence the use of coronary CT angiography with prospective ECG gating allows for a reduced radiation exposure without a sacrifice in diagnostic efficacy.
引用
收藏
页码:2109 / 2119
页数:11
相关论文
共 46 条
  • [1] 64-multislice detector computed tomography coronary angiography as potential alternative to conventional coronary angiography: a systematic review and meta-analysis
    Abdulla, Jawdat
    Abildstrom, Steen Z.
    Gotzsche, Ole
    Christensen, Erik
    Kober, Lars
    Torp-Pedersen, Christian
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 (24) : 3042 - 3050
  • [2] Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition
    Achenbach, Stephan
    Marwan, Mohamed
    Ropers, Dieter
    Schepis, Tiziano
    Pflederer, Tobias
    Anders, Katharina
    Kuettner, Axel
    Daniel, Werner G.
    Uder, Michael
    Lell, Michael M.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 (03) : 340 - 346
  • [3] Low-dose, 128-slice, dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot mode
    Alkadhi, Hatem
    Stolzmann, Paul
    Desbiolles, Lotus
    Baumueller, Stephan
    Goetti, Robert
    Plass, Andre
    Scheffel, Hans
    Feuchtner, Gudrun
    Falk, Volkmar
    Marincek, Borut
    Leschka, Sebastian
    [J]. HEART, 2010, 96 (12) : 933 - 938
  • [4] Adequate image quality with reduced radiation dose in prospectively triggered coronary CTA compared with retrospective techniques
    Arnoldi, Elisabeth
    Johnson, Thorsten R.
    Rist, Carsten
    Wintersperger, Bernd J.
    Sommer, Wieland H.
    Becker, Alexander
    Becker, Christoph R.
    Reiser, Maximilian F.
    Nikolaou, Konstantin
    [J]. EUROPEAN RADIOLOGY, 2009, 19 (09) : 2147 - 2155
  • [5] BONGARTZ G, 2004, 16262 EUR EN EUR COM
  • [6] Current concepts - Computed tomography - An increasing source of radiation exposure
    Brenner, David J.
    Hall, Eric J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) : 2277 - 2284
  • [7] Accuracy of low-dose prospectively gated axial coronary CT angiography for the assessment of coronary artery stenosis in patients with stable heart rate
    Carrascosa, Patricia
    Capunay, Carlos
    Deviggiano, Alejandro
    Goldsmit, Alejandro
    Tajer, Carlos
    Bettinotti, Marcelo
    Carrascosa, Jorge
    Ivanc, Thomas B.
    Fallahi, Arzhang
    Garcia, Mario J.
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2010, 4 (03) : 197 - 205
  • [8] The diagnostic accuracy of 256-row computed tomographic angiography compared with invasive coronary angiography in patients with suspected coronary artery disease
    Chao, Shu-Ping
    Law, Wai-Yip
    Kuo, Chu-Jen
    Hung, Huei-Fong
    Cheng, Jun-Jack
    Lo, Huey-Ming
    Shyu, Kou-Gi
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 (15) : 1916 - 1923
  • [9] Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease
    de Graaf, Fleur R.
    Schuijf, Joanne D.
    van Velzen, Joella E.
    Kroft, Lucia J.
    de Roos, Albert
    Reiber, Johannes H. C.
    Boersma, Eric
    Schalij, Martin J.
    Spano, Fabrizio
    Jukema, J. Wouter
    van der Wall, Ernst E.
    Bax, Jeroen J.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 (15) : 1908 - 1915
  • [10] Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic Accuracy Comparison of Results With Cardiac Catheterization in a Head-to-Head Pilot Investigation
    Dewey, Marc
    Zimmermann, Elke
    Deissenrieder, Florian
    Laule, Michael
    Duebel, Hans-Peter
    Schlattmann, Peter
    Knebel, Fabian
    Rutsch, Wolfgang
    Hamm, Bernd
    [J]. CIRCULATION, 2009, 120 (10) : 867 - 875