Fabrication and optimal design of differential electromagnetic transducer for implantable middle ear hearing device

被引:9
作者
Kim, MK
Park, IY
Song, BS
Cho, JH
机构
[1] Kynungpook Natl Univ, Dept Med & Biol Engn, Taegu 700422, South Korea
[2] Daegu Univ, Dept Rehabil Sci & Technol, Taegu 700422, South Korea
[3] Kynungpook Natl Univ, Adv Res Ctr Recovery Human Sensibil, Taegu 700422, South Korea
关键词
differential electromagnetic transducer; vibration frequency characteristics; FEA; implantable middle ear hearing devices;
D O I
10.1016/j.bios.2005.10.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A differential electromagnetic transducer (DET), with similar frequency characteristics to those of a normal middle ear, is designed and implemented for use in an implantable middle car hearing device (IMEHD). To optimize the characteristics of the DET that depend on the electromagnetically forced vibration, a theoretical analysis is conducted to design the vibrating part. The electromagnetic force of the DET is Simulated according to the design parameters of the coil Size using a finite element analysis (FEA). As a result, the maximal vibration force is achieved when the optimal length and thickness of the cylindrical coil is 70% of the length of the magnets and 56% of their radius. The vibration characteristics of the DET are then simulated when applying the maximal force. The optimally designed DET is implemented using MEMS technology and vibration experiments carried out with the fabricated DET in an unloaded state. The vibrating displacement of the DET is about 200 nm within a range between 0.1 and 1.5 kHz when a current of 1 mA(rms), is applied to the coil. To investigate the usefulness of the DET, in vitro and in vivo experiments are conducted using the ossicular chain of a cadaver and guinea pig, and the results verify that the implemented DET performs well as a transducer for an IMEHD. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:2170 / 2175
页数:6
相关论文
共 11 条
[1]  
Abbass H A, 1997, Ear Nose Throat J, V76, P321
[2]   Phase 1 clinical trial results of the envoy system: A totally implantable middle ear device for sensorineural hearing loss [J].
Chen, DA ;
Backous, DD ;
Arriaga, MA ;
Garvin, R ;
Kobylek, D ;
Littman, T ;
Walgren, S ;
Lura, D .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2004, 131 (06) :904-916
[3]  
DIETZ TG, 1997, P TRANSD 97, P433
[4]  
FREDERICKSON JM, 1995, OTOLARYNG CLIN N AM, V28, P107
[5]  
GOODE RL, 1995, OTOLARYNG CLIN N AM, V28, P1
[6]  
KO WH, 1995, OTOLARYNG CLIN N AM, V28, P29
[7]  
KOHNKE P, 1994, USERS MANUAL 4
[8]  
Song BS, 2004, IEICE T INF SYST, VE87D, P1231
[9]  
Song BS, 2002, IEICE T ELECTRON, VE85C, P1374
[10]  
SUZUKI JI, 1988, ADV AUDIOL, V4, P15