We report the development of a practical ultrafast allelic profiling assay for the analysis of short tandem repeats (STRs) by using a highly optimized microfluidic electrophoresis device. We have achieved baseline-resolved electrophoretic separations of single-locus STR samples in 30 sec. Analyses of PCR samples containing the four loci CSF1PO, TPOX, THO1, and vWA (abbreviated as CTTv) were performed in less than 2 min. This constitutes a 10- to 100-fold improvement in speed relative to capillary or slab gel systems. The separation device consists of a microfabricated channel 45 mu m x 100 mu m in cross section and 26 mm in length, filled with a replaceable polyacrylamide matrix operated under denaturing conditions at 50 degrees C, A fluorescently labeled STR ladder was used as an internal standard for allele identification. Samples were prepared by standard procedures and only 4 mu l was required for each analysis. The device is capable of repetitive operation and is suitable for automated high-speed and high-throughput applications.
引用
收藏
页码:10273 / 10278
页数:6
相关论文
共 32 条
[1]   SURVEY OF HUMAN AND RAT MICROSATELLITES [J].
BECKMANN, JS ;
WEBER, JL .
GENOMICS, 1992, 12 (04) :627-631
[2]  
Belgrader P, 1997, LAB ROBOTICS AUTOMAT, V9, P3, DOI 10.1002/(SICI)1098-2728(1997)9:1<3::AID-LRA2>3.0.CO
[3]  
2-4
[4]  
BUDOWLE B, 1991, AM J HUM GENET, V48, P137
[5]  
BUTLER JM, 1994, BIOTECHNIQUES, V17, P1062
[6]   APPLICATION OF DUAL INTERNAL STANDARDS FOR PRECISE SIZING OF POLYMERASE CHAIN-REACTION PRODUCTS USING CAPILLARY ELECTROPHORESIS [J].
BUTLER, JM ;
MCCORD, BR ;
JUNG, JM ;
LEE, JA ;
BUDOWLE, B ;
ALLEN, RO .
ELECTROPHORESIS, 1995, 16 (06) :974-980
[7]  
EDWARDS A, 1991, AM J HUM GENET, V49, P746
[8]   HIGH-SPEED SEPARATION OF ANTISENSE OLIGONUCLEOTIDES ON A MICROMACHINED CAPILLARY ELECTROPHORESIS DEVICE [J].
EFFENHAUSER, CS ;
PAULUS, A ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2949-2953
[9]   MICROMACHINING OF CAPILLARY ELECTROPHORESIS INJECTORS AND SEPARATORS ON GLASS CHIPS AND EVALUATION OF FLOW AT CAPILLARY INTERSECTIONS [J].
FAN, ZH ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :177-184
[10]  
FREGEAU CJ, 1993, BIOTECHNIQUES, V15, P100