Effect of Physician Training on the X-Ray Dose Delivered During Coronary Angioplasty

被引:0
作者
Ramon Azpiri-Lopez, Jose [1 ]
Luis Assad-Morell, Jose [1 ]
Gerardo Gonzalez-Gonzalez, Jose [2 ]
Elizondo-Riojas, Guillermo [3 ]
Davila-Bortoni, Adrian [1 ]
Garcia-Martinez, Rodrigo [1 ]
Trevino-Frutos, Ramon [1 ]
机构
[1] Hosp Christus Muguerza Alta Especialidad Monterre, Monterrey, Nuevo Leon, Mexico
[2] Univ Autonoma Nuevo Leon, Fac Med, Subdirecc Invest, Monterrey, Nuevo Leon, Mexico
[3] Univ Autonoma Nuevo Leon, Fac Med, Ctr Univ Imagen Diagnost, Monterrey, Nuevo Leon, Mexico
关键词
percutaneous coronary intervention; radiation exposure; radiation safety; dose reference level; reference point air kerma; kerma area product; dosimetry; RADIATION; ANGIOGRAPHY; REDUCTION;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. To assess whether physician training helps decrease the amount of radiation delivered to patients undergoing coronary angioplasty with stent placement. Background. Coronary angioplasty exposes patients to high doses of ionizing radiation, possibly related to equipment misuse or inappropriate training. Methods. Reference point air kerma (K-a,K-r) and kerma area product (P-KA) were prospectively registered during a period of 6 months in patients undergoing coronary angiography and angioplasty with stent ad hoc. All interventionalists were then invited to an informative conference on appropriate use of radiation and changes in x-ray delivery settings. Data were recorded during the following 6 months and then compared for the whole group and for those who did or did not attend the conference. Results. K-a,K-r decreased from 5.44 +/- 0.3 Gy (n = 106) to 3.39 +/- 0.22 Gy (n = 112); P<.0001 and P-KA decreased from 365.4 +/- 21.1 Gy.cm(-2) to 233.7 +/- 13.1 Gy.cm(-2); P<.0001. During the first 6 months, there were no differences in radiation emitted among physicians; however, during the second half of the study, there was a 34% difference in K-a,K-r between those that attended the conference and those who did not (2.78 +/- 0.23 Gy vs 4.18 +/- 0.37 Gy; P = .002), regardless of the fact that both groups lowered radiation emission settings. Conclusion. Changes in x-ray parameters profoundly reduce the amount of radiation delivered to patients, a situation that was more evident in those who attended an informative conference. It is important to educate cardiologists in the appropriate use of modern x-ray equipment. J INVASIVE CARDIOL 2013;25(3):109-113
引用
收藏
页码:109 / 113
页数:5
相关论文
共 50 条
  • [21] Context sensitive cardiac x-ray imaging: a machine vision approach to x-ray dose control
    Kengyelics, Stephen M.
    Gislason-Lee, Amber J.
    Keeble, Claire
    Magee, Derek R.
    Davies, Andrew G.
    JOURNAL OF ELECTRONIC IMAGING, 2015, 24 (05)
  • [22] X-RAY DOSE ESTIMATION FROM CATHODE RAY TUBE MONITORS BY MONTE CARLO CALCULATION
    Khaledi, Navid
    Arbabi, Azim
    Dabaghi, Moloud
    HEALTH PHYSICS, 2015, 108 (04): : 401 - 406
  • [23] Significant Radiation Dose Reduction in the Hybrid Operating Room Using a Novel X-ray Imaging Technology
    van den Haak, R. F. F.
    Hamans, B. C.
    Zuurmond, K.
    Verhoeven, B. A. N.
    Koning, O. H. J.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 50 (04) : 480 - 486
  • [24] Comparison of in-phantom dose distributions for coronary angiography using an x-ray machine and synchrotron radiation
    Nariyama, N
    Tanaka, S
    Nakane, Y
    Nakashima, H
    Hirayama, H
    Ban, S
    Namito, Y
    Hyodo, K
    Takeda, T
    MEDICAL PHYSICS, 2001, 28 (01) : 16 - 21
  • [25] Effect of X-ray Radiation Dose on the Bond Strength of Different Adhesive Systems to Dentin
    Biscaro, Sandro L.
    Moraes, Rafael R.
    Correr, Americo B.
    Almeida, Solange M.
    Boscolo, Frab N.
    Soares, Carlos J.
    Correr-Sobrinho, Lourenco
    JOURNAL OF ADHESIVE DENTISTRY, 2009, 11 (05) : 355 - 360
  • [26] Effect of low dose X-ray on membrane fluidity of thalassemic red blood cells
    Udomtanakunchai, C.
    Mernsri, S.
    Jeejai, S.
    Intachai, N.
    Ruengdit, C.
    Pornprasert, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (01): : 75 - 80
  • [27] ESTIMATION OF EFFECTIVE DOSE OF DENTAL X-RAY DEVICES
    Qiang, Wang
    Qiang, Fu
    Lin, Lin
    RADIATION PROTECTION DOSIMETRY, 2019, 183 (04) : 418 - 422
  • [28] Dose optimization in pediatric cardiac x-ray imaging
    Gislason, Amber J.
    Davies, Andrew G.
    Cowen, Arnold R.
    MEDICAL PHYSICS, 2010, 37 (10) : 5258 - 5269
  • [29] Organ-based estimation and minimization of clinician's X-ray dose
    Krebs, Alexandre
    Mazellier, Jean-Paul
    Verde, Juan
    Rolland, Cindy
    Bert, Julien
    Padoy, Nicolas
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (12) : 2357 - 2364
  • [30] Suitability of laser stimulated TLD arrays as patient dose monitors in high dose x-ray imaging
    Geise, RA
    Schueler, BA
    Lien, W
    Jones, SC
    MEDICAL PHYSICS, 1997, 24 (10) : 1643 - 1646