64-slice coronary computed tomography angiography using low tube voltage of 80 kV in subjects with normal body mass indices: comparative study using 120 kV

被引:23
作者
Jun, Bo Ram [1 ]
Yong, Hwan Seok [1 ]
Kang, Eun-Young [1 ]
Woo, Ok Hee [1 ]
Choi, Eun Jung [1 ]
机构
[1] Korea Univ, Coll Med, Dept Radiol, Guro Hosp, Seoul 136705, South Korea
关键词
Coronary CT angiography; radiation dose; image quality; DUAL-SOURCE CT; RADIATION-EXPOSURE; IMAGE QUALITY; PROTOCOLS; ACCURACY;
D O I
10.1258/ar.2012.110573
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The radiation dose of coronary computed tomography (CT) angiography (CCTA) is generally higher than that of CT scans of other parts of the body, and there is concern that the high radiation dose may result in increased cancer risk. Although various techniques have recently been introduced to lower the radiation dose of CCTA, there has been no direct comparison between protocols with 80 and 120 kV. Purpose: To assess the image quality and radiation dose of 80-kV electrocardiography (ECG)-gated CCTA in subjects with a normal body mass index (BMI), compared to 120-kV ECG-gated CCTA. Material and Methods: This retrospective study was approved by our local ethics board, and the requirement of written informed consent was waived. We analyzed the CCTA images of 100 subjects with BMIs <25 kg/m(2). Fifty subjects underwent 120-kV CCTA, and the other 50 subjects underwent 80-kV CCTA. Two blinded observers independently evaluated the subjective image quality of the coronary arteries. The objective image quality (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]) and radiation dose were also measured in each group. Results: Although the objective image quality of the 80-kV protocol images was significantly poorer than that of 120-kV protocol images (mean SNR, 14.9 +/- 4.7 vs. 19.8 +/- 4.4, P < 0.0001; mean CNR, 15.2 +/- 4.8 vs. 21.6 +/- 4.7, P < 0.0001), there was no significant difference in the subjective image quality between the two groups (mean image score, 4.7 +/- 1.1 vs. 4.5 +/- 0.7 for radiologist 1, P = 0.273; 5.0 +/- 1.0 vs. 4.8 +/- 1.0 for radiologist 2, P = 0.197). The radiation dose was reduced by 70% with the 80-kV protocol and by 88% with the 80-kV and ECG-based tube current modulation than with the 120-kV protocol (3.42 +/- 1.16 and 2.9 +/- 0.8 vs. 11.49 +/- 3.62 mSv, P < 0.0001). Conclusion: The low tube voltage CCTA protocol using 80 kV allows significant reduction of the radiation dose without impairing the subjective image quality in subjects with normal BMIs.
引用
收藏
页码:1099 / 1106
页数:8
相关论文
共 21 条
[1]   MDCT of the coronary arteries: Feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose [J].
Abada, Hicham T. ;
Larchez, Christophe ;
Daoud, Beatrice ;
Sigal-Cinqualbre, Anne ;
Paul, Jean-Francois .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) :S387-S390
[2]  
Abbara Suhny, 2009, J Cardiovasc Comput Tomogr, V3, P190, DOI 10.1016/j.jcct.2009.03.004
[3]   Radiation dose of cardiac CT-what is the evidence? [J].
Alkadhi, Hatem .
EUROPEAN RADIOLOGY, 2009, 19 (06) :1311-1315
[4]   Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product [J].
Deak, Paul D. ;
Smal, Yulia ;
Kalender, Willi A. .
RADIOLOGY, 2010, 257 (01) :158-166
[5]   Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323
[6]   Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study [J].
Hara, Amy K. ;
Paden, Robert G. ;
Silva, Alvin C. ;
Kujak, Jennifer L. ;
Lawder, Holly J. ;
Pavlicek, William .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :764-771
[7]   Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates [J].
Hausleiter, J ;
Meyer, T ;
Hadamitzky, M ;
Huber, E ;
Zankl, M ;
Martinoff, S ;
Kastrati, A ;
Schömig, A .
CIRCULATION, 2006, 113 (10) :1305-1310
[8]   Estimated Radiation Dose Associated With Cardiac CT Angiography [J].
Hausleiter, Joerg ;
Meyer, Tanja ;
Hermann, Franziska ;
Hadamitzky, Martin ;
Krebs, Markus ;
Gerber, Thomas C. ;
McCollough, Cynthia ;
Martinoff, Stefan ;
Kastrati, Adnan ;
Schoemig, Albert ;
Achenbach, Stephan .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (05) :500-507
[9]   Image Quality and Radiation Exposure With a Low Tube Voltage Protocol for Coronary CT Angiography Results of the PROTECTION II Trial [J].
Hausleiter, Jorg ;
Martinoff, Stefan ;
Hadamitzky, Martin ;
Martuscelli, Eugenio ;
Pschierer, Iris ;
Feuchtner, Gudrun M. ;
Catalan-Sanz, Paz ;
Czermak, Benedikt ;
Meyer, Tanja S. ;
Hein, Franziska ;
Bischoff, Bernhard ;
Kuse, Miriam ;
Schomig, Albert ;
Achenbach, Stephan .
JACC-CARDIOVASCULAR IMAGING, 2010, 3 (11) :1113-1123
[10]   Comparison of diagnostic accuracy of 64-slice computed tomography coronary angiography in patients with low, intermediate, and high cardiovascular risk [J].
Husmann, Lars ;
Schepis, Tiziano ;
Scheffel, Hans ;
Gaemperli, Oliver ;
Leschka, Sebastian ;
Valenta, Ines ;
Koepfli, Pascal ;
Desbiolles, Lotus ;
Stolzmann, Paul ;
Marincek, Borut ;
Alkadhi, Hatem ;
Kaufmann, Philipp A. .
ACADEMIC RADIOLOGY, 2008, 15 (04) :452-461