Evaluating the effect of reduced entrance surface dose on neonatal chest imaging using subjective image quality evaluation

被引:12
作者
Conradie, Anita [1 ]
Herbst, Charles Petrus [1 ]
机构
[1] Univ Free State, Dept Med Phys, ZA-9300 Bloemfontein, South Africa
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2016年 / 32卷 / 10期
关键词
Neonatal; Chest X-rays; Dose; Rabbit phantom; Image quality; INTENSIVE-CARE-UNIT; RADIATION-EXPOSURE; RADIOGRAPHY; OPTIMIZATION; REDUCTION;
D O I
10.1016/j.ejmp.2016.07.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: As hospitalized neonates are radiosensitive and often require numerous X-rays, institutions should investigate the optimal beam parameter combinations to deliver diagnostically acceptable quality images at the lowest possible entrance surface dose (ESD). Using a subjective approach, this study evaluated the effect of different beam parameter combinations on image quality. Methods and materials: Five rabbits simulated the neonatal chest. The ESD was reduced using a variation of voltage, tube current and filtration. Eight radiology registrars, blinded to the dose parameter information, ranked the digital X-ray images of three anatomical regions from best to worst using a variation of the multiple rank order method. T-tests compared the average values, obtained from the scores assigned by each observer to images acquired at different ESDs, for each region. The calculated intraclass correlation coefficient (ICC) assessed observer agreement. Results: Results showed that a 64% dose reduction was achievable by altering the beam parameters. Large variation among the observers was confirmed by an ICC value <0.5. A 95% confidence interval could not conclude that different ESD values, resulting in a 50-77% dose reduction compared to current practice, would result in different overall observed image quality. This was noted for all three regions indicating that no preference existed towards an image acquired with a specific beam parameter combination. Conclusions: The large variation in observers' opinion of acceptable image quality emphasizes the importance of subjective image quality evaluation in the clinical environment. The rabbit phantom and multiple rank order method are considered appropriate for these evaluations. (C) 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1368 / 1374
页数:7
相关论文
共 23 条
  • [1] Radiation dose quantities and risk in neonates in a special care baby unit
    Armpilia, CI
    Fife, IAJ
    Croasdale, PL
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (895) : 590 - 595
  • [2] Flat-panel display (LCD) versus high-resolution gray-scale display (CRT) for chest radiography: An observer preference study
    Balassy, C
    Prokop, M
    Weber, M
    Sailer, J
    Herold, CJ
    Schaefer-Prokop, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (03) : 752 - 756
  • [3] Bogdanich W, 2011, NY TIMES
  • [4] Department of Health Directorate Radiation Control 2014, 2014, CODE DIAGNOSTIC QC V
  • [5] Dose and image quality optimization in neonatal radiography
    Dougeni, E. D.
    Delis, H. B.
    Karatza, A. A.
    Kalogeropoulou, C. P.
    Skiadopoulos, S. G.
    Mantagos, S. P.
    Panayiotakis, G. S.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (958) : 807 - 815
  • [6] Suitability of LiF:Mg,Cu,P and Al2O3:C for low dose measurements in medical imaging
    Duggan, L
    Sathiakumar, C
    Warren-Forward, H
    Symonds, M
    McConnell, P
    Smith, T
    Kron, T
    [J]. RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 425 - 428
  • [7] Erasmus A., 2015, THESIS
  • [8] European Commission, 1996, 16261 EUR
  • [9] Radiation dose to neonates undergoing X-ray imaging in special care baby units in Iran
    Faghihi, Reza
    Mehdizadeh, Simin
    Sina, Sedigheh
    Alizadeh, Fatemeh N.
    Zeinali, Banafsheh
    Kamyab, Gholam Reza
    Aghevlian, Sadaf
    Khorramdel, Hossein
    Namazi, Imen
    Heirani, Mandana
    Moshkriz, Meisam
    Mahani, Hojjat
    Sharifzadeh, Mohsen
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 150 (01) : 55 - 59
  • [10] Radiation dose reduction in a neonatal intensive care unit in computed radiography
    Frayre, A. S.
    Torres, P.
    Gaona, E.
    Rivera, T.
    Franco, J.
    Molina, N.
    [J]. APPLIED RADIATION AND ISOTOPES, 2012, 71 : 57 - 60