OSL films for in-vivo entrance dose measurements

被引:12
作者
Souza, S. O. [1 ]
d'Errico, F. [1 ,2 ,3 ]
Azimi, B. [1 ]
Baldassare, A. [2 ]
Alves, A. V. S. [1 ]
Valenca, J. V. B. [1 ]
Barros, V. S. M. [4 ]
Cascone, M. G. [2 ]
Lazzeri, L. [2 ]
机构
[1] Univ Fed Sergipe, Dept Fis, Av Marechal Rondon S-N, BR-49100000 Sao Cristovao, SE, Brazil
[2] Univ Pisa, Scuola Ingn, Largo L Lazzarino 2, I-56125 Pisa, Italy
[3] Yale Univ, Sch Med, POB 208042, New Haven, CT 06520 USA
[4] Univ Fed Pernambuco, Dept Energia Nucl, Av Prof Luiz Freire 1000, BR-50740540 Recife, PE, Brazil
基金
巴西圣保罗研究基金会;
关键词
OSL film; Entrance dose; In-vivo dosimetry; OPTICALLY STIMULATED LUMINESCENCE; DIAGNOSTIC-RADIOLOGY; FIBEROPTIC DOSIMETER; RADIOTHERAPY; SYSTEM; PHOTON; AL2O3; BEAMS; QA;
D O I
10.1016/j.radmeas.2017.07.006
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Measuring entrance exposures to diagnostic or therapeutic radiology patients is valuable to infer dose distributions within their bodies in order to minimize unnecessary exposures. For this purpose, we investigated the development of dosimeters consisting of waterproof, transparent, and flexible films containing OSL microcrystals. In our method, films are produced by casting solutions, followed by solvent evaporation. Non-aggressive chemicals are used, which allows the production of films containing large quantities of crystals without altering their structure. In this proof of principle study, we chose polyvinyl chloride (PVC) as a polymer matrix due to its high transparency and its waterproof nature and we produced films loaded with microcrystals of CaF2:Ce. A mixture of acetone:benzene (40:60 wt%) was selected as the best solvent for producing PVC films loaded with CaF2:Ce crystals. This solvent offers ease of handling, low toxicity, low cost, and does not affect the crystal structure nor its OSL emission. The PVC films can be loaded with any luminescent material. For proof of concept we chose to load them with CaF2:Ce micron sized particles because they emit an intense OSL signal for a low beta dose of 100 mGy, showing very good sensitivity for dosimetric applications. Our results indicate that films loaded with OSL crystals may be suitable for the production of a novel OSL dosimeter, which adheres closely to the body and could be used during a radiological procedure to estimate the entrance dose. As OSL materials are sensitive to light, somehow the films would have to be shielded from light for dosimetric purposes. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:644 / 649
页数:6
相关论文
共 31 条
  • [1] Characterization of Al2O3 optically stimulated luminescence films for 2D dosimetry using a 6 MV photon beam
    Ahmed, M. F.
    Shrestha, N.
    Schnell, E.
    Ahmad, S.
    Akselrod, M. S.
    Yukihara, E. G.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (21) : 7551 - 7570
  • [2] Development of a 2D dosimetry system based on the optically stimulated luminescence of Al2O3
    Ahmed, M. F.
    Eller, S. A.
    Schnell, E.
    Ahmad, S.
    Akselrod, M. S.
    Hanson, O. D.
    Yukihara, E. G.
    [J]. RADIATION MEASUREMENTS, 2014, 71 : 187 - 192
  • [3] Optically stimulated luminescence of CaF2:Tm
    Asfora, Viviane K.
    de Barros, Vinicius S. M.
    da Silva, Regina J. G.
    Vasconcelos, Daniel A. A.
    Nobre, Bruno S.
    Yamato, Maria E.
    Khoury, Helen J.
    Oliveira, Raquel A.
    Azevedo, Walter M.
    [J]. RADIATION MEASUREMENTS, 2016, 85 : 73 - 77
  • [4] Application of the dry-spinning method to produce poly(ε-caprolactone) fibers containing bovine serum albumin laden gelatin nanoparticles
    Azimi, Bahareh
    Nourpanah, Parviz
    Rabiee, Mohammad
    Arbab, Shahram
    Cascone, Maria Grazia
    Baldassare, Andrea
    Lazzeri, Luigi
    [J]. JOURNAL OF APPLIED POLYMER SCIENCE, 2016, 133 (48)
  • [5] Characterization of a fiber-optic-coupled radioluminescent detector for application in the mammography energy range
    Benevides, Luis A.
    Huston, Alan L.
    Justus, Brian L.
    Falkenstein, Paul
    Brateman, Libby F.
    Hintenlang, David E.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2220 - 2227
  • [6] Water equivalence of plastic organic scintillators in megavoltage radiotherapy bremsstrahlung beams
    Clift, MA
    Sutton, RA
    Webb, DV
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (07) : 1885 - 1895
  • [7] Postoperative concurrent radiotherapy and chemotherapy for high-risk squamous-cell carcinoma of the head and neck
    Cooper, JS
    Pajak, TF
    Forastiere, AA
    Jacobs, J
    Campbell, BH
    Saxman, SB
    Kish, JA
    Kim, HE
    Cmelak, AJ
    Rotman, M
    Machtay, M
    Ensley, JF
    Chao, KSC
    Schultz, CJ
    Lee, N
    Fu, KK
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (19) : 1937 - 1944
  • [8] Dosimetric issues in radiation protection of radiotherapy patients
    d'Errico, Francesco
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 118 (02) : 205 - 212
  • [9] Relationships between entrance skin dose, effective dose and dose area product for patients in diagnostic and interventional cardiac procedures
    Hansson, B
    Karambatsakidou, A
    [J]. RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 141 - 144
  • [10] Characterization of a water-equivalent fiber-optic coupled dosimeter for use in diagnostic radiology
    Hyer, Daniel E.
    Fisher, Ryan F.
    Hintenlang, David E.
    [J]. MEDICAL PHYSICS, 2009, 36 (05) : 1711 - 1716