On-line sequential injection-capillary electrophoresis for near-real-time monitoring of extracellular lactate in cell culture flasks

被引:24
作者
Alhusban, Ala A. [1 ,2 ]
Gaudry, Adam J. [2 ]
Breadmore, Michael C. [2 ]
Gueven, Nuri [3 ]
Guijt, Rosanne M. [1 ]
机构
[1] Univ Tasmania, Sch Pharm, Fac Hlth Sci, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
[2] Univ Tasmania, Sch Chem, Fac Sci Engn & Technol, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
[3] Univ Tasmania, Sch Pharm, Fac Hlth Sci, Hobart, Tas 7001, Australia
基金
澳大利亚研究理事会;
关键词
Sequential injection capillary; electrophoresis; Online monitoring; Bio process monitoring; Capillary electrophoresis; Cell culture; ELECTROKINETIC INJECTION; LACTIC-ACID; ISOTACHOPHORESIS; FERMENTATION; METABOLISM;
D O I
10.1016/j.chroma.2013.11.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cell culture has replaced many in vivo studies because of ethical and regulatory measures as well as the possibility of increased throughput. Analytical assays to determine (bio)chemical changes are often based on end-point measurements rather than on a series of sequential determinations. The purpose of this work is to develop an analytical system for monitoring cell culture based on sequential injection-capillary electrophoresis (SI-CE) with capacitively coupled contactless conductivity detection ((CD)-D-4). The system was applied for monitoring lactate production, an important metabolic indicator, during mammalian cell culture. Using a background electrolyte consisting of 25 mM tris(hydroxymethyl)aminomethane, 35 mM cyclohexyl-2-aminoethanesulfonic acid with 0.02% poly(ethyleneimine) (PEI) at pH 8.65 and a multilayer polymer coated capillary, lactate could be resolved from other compounds present in media with relative standard deviations 0.07% for intraday electrophoretic mobility and an analysis time of less than 10 min. Using the human embryonic kidney cell line HEK293, lactate concentrations in the cell culture medium were measured every 20 min over 3 days, requiring only 8.73 mu L of sample per run. Combining simplicity, portability, automation, high sample throughput, low limits of detection, low sample consumption and the ability to up- and outscale, this new methodology represents a promising technique for near real-time monitoring of chemical changes in diverse cell culture applications. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 29 条
[1]   Bioprocess control: Advances and challenges [J].
Alford, Joseph S. .
COMPUTERS & CHEMICAL ENGINEERING, 2006, 30 (10-12) :1464-1475
[2]   Capillary electrophoresis for monitoring bioprocesses [J].
Alhusban, Ala A. ;
Breadmore, Michael C. ;
Guijt, Rosanne M. .
ELECTROPHORESIS, 2013, 34 (11) :1465-1482
[3]   Cell lines as in vitro models for drug screening and toxicity studies [J].
Allen, DD ;
Caviedes, R ;
Cárdenas, AM ;
Shimahara, T ;
Segura-Aguilar, J ;
Caviedes, PA .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2005, 31 (08) :757-768
[4]   Identification of Inorganic Improvised Explosive Devices Using Sequential Injection Capillary Electrophoresis and Contactless Conductivity Detection [J].
Blanco, Gustavo A. ;
Nai, Yi H. ;
Hilder, Emily F. ;
Shellie, Robert A. ;
Dicinoski, Greg W. ;
Haddad, Paul R. ;
Breadmore, Michael C. .
ANALYTICAL CHEMISTRY, 2011, 83 (23) :9068-9075
[5]   Recent advances in enhancing the sensitivity of electrophoresis and electrochromatography in capillaries and microchips (2008-2010) [J].
Breadmore, Michael C. ;
Dawod, Mohamed ;
Quirino, Joselito P. .
ELECTROPHORESIS, 2011, 32 (01) :127-148
[6]   Recent advances in enhancing the sensitivity of electrophoresis and electrochromatography in capillaries and microchips (2006-2008) [J].
Breadmore, Michael C. ;
Thabano, Jonathan R. E. ;
Dawod, Mohamed ;
Kazarian, Artaches A. ;
Quirino, Joselito P. ;
Guijt, Rosanne M. .
ELECTROPHORESIS, 2009, 30 (01) :230-248
[7]   An overview of drug screening using primary and embryonic stem cells [J].
Eglen, Richard M. ;
Gilchrist, Annette ;
Reisine, Terry .
COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2008, 11 (07) :566-572
[8]   Development and validation of a capillary electrophoresis method with capacitively coupled contactless conductivity detection (CE-C4D) for the analysis of amikacin and its related substances [J].
El-Attug, Mohamed Nouri ;
Adams, Erwin ;
Van Schepdael, Ann .
ELECTROPHORESIS, 2012, 33 (17) :2777-2782
[9]   Applications of capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C4D) in pharmaceutical and biological analysis [J].
Elbashir, Abdalla A. ;
Aboul-Enein, Hassan Y. .
BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (10) :1038-1044
[10]   Monitoring the lactic acid bacterial diversity during Shochu fermentation by PCR-denaturing gradient gel electrophoresis [J].
Endo, A ;
Okada, S .
JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2005, 99 (03) :216-221