Quantifying the effect of slice thickness, intravenous contrast and tube current on muscle segmentation: Implications for body composition analysis

被引:68
作者
Fuchs, Georg [1 ,2 ]
Chretien, Yves R. [2 ]
Mario, Julia [2 ]
Do, Synho [2 ]
Eikermann, Matthias [3 ,4 ]
Liu, Bob [2 ]
Yang, Kai [2 ]
Fintelmann, Florian J. [2 ]
机构
[1] Charite, Dept Radiol, Charitepl 1, D-10117 Berlin, Germany
[2] Massachusetts Gen Hosp, Dept Radiol, 55 Fruit St, Boston, MA 02114 USA
[3] Dept Anesthesia Crit Care & Pain Med, 55 Fruit St, Boston, MA 02114 USA
[4] Beth Israel Deaconess Med Ctr, HMFP, 330 Brookline Ave, Boston, MA 02215 USA
关键词
Body composition; Muscles; Tomography; X-Ray Computed; Image Interpretation; Computer-Assisted; Abdomen; COMPUTED-TOMOGRAPHY; SKELETAL-MUSCLE; RECONSTRUCTION TECHNIQUES; DIFFERENT MANUFACTURERS; SARCOPENIC OBESITY; COLORECTAL-CANCER; SOFTWARE; SURGERY; VOLUME; ATTENUATION;
D O I
10.1007/s00330-017-5191-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To quantify the effect of IV contrast, tube current and slice thickness on skeletal muscle cross-sectional area (CSA) and density (SMD) on routine CT. CSA and SMD were computed on 216 axial CT images obtained at the L3 level in 72 patients with variations in IV contrast, slice thickness and tube current. Intra-patient mean difference (MD), 95 % CI and limits of agreement were calculated using the Bland-Altman approach. Inter- and intra-analyst agreement was evaluated. IV contrast significantly increased CSA by 1.88 % (MD 2.33 cm(2); 95 % CI 1.76-2.89) and SMD by 5.99 % (p < 0.0001). Five mm slice thickness significantly increased mean CSA by 1.11 % compared to 2 mm images (1.32 cm(2); 0.78-1.85) and significantly decreased SMD by 11.64 % (p < 0.0001). Low tube current significantly decreased mean CSA by 4.79 % (6.44 cm(2); 3.78-9.10) and significantly increased SMD by 46.46 % (p < 0.0001). Inter- and intra-analyst agreement was excellent. IV contrast, slice thickness and tube current significantly affect CSA and SMD. Investigators designing and analysing clinical trials using CT for body composition analysis should report CT acquisition parameters and consider the effect of slice thickness, IV contrast and tube current on myometric data. aEuro cent Intravenous contrast, slice thickness and tube current significantly affect myometric data. aEuro cent Image acquisition parameter variations may obscure intrapatient muscle differences on serial measurements. aEuro cent Investigators using CT for body composition analysis should report CT acquisition parameters.
引用
收藏
页码:2455 / 2463
页数:9
相关论文
共 37 条
[1]   Algorithm Variability in the Estimation of Lung Nodule Volume From Phantom CT Scans: Results of the QIBA 3A Public Challenge [J].
Athelogou, Maria ;
Kim, Hyun J. ;
Dima, Alden ;
Obuchowski, Nancy ;
Peskin, Adele ;
Gavrielides, Marios A. ;
Petrick, Nicholas ;
Saiprasad, Ganesh ;
Colditz, Dirk Colditz ;
Beaumont, Hubert ;
Oubel, Estanislao ;
Tan, Yongqiang ;
Zhao, Binsheng ;
Kuhnigk, Jan-Martin ;
Moltz, Jan Hendrik ;
Orieux, Guillaume ;
Gillies, Robert J. ;
Gu, Yuhua ;
Mantri, Ninad ;
Goldmacher, Gregory ;
Zhang, Luduan ;
Vega, Emilio ;
Bloom, Michael ;
Jarecha, Rudresh ;
Soza, Grzegorz ;
Tietjen, Christian ;
Takeguchi, Tomoyuki ;
Yamagata, Hitoshi ;
Peterson, Sam ;
Masoud, Osama ;
Buckler, Andrew J. .
ACADEMIC RADIOLOGY, 2016, 23 (08) :940-952
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Boutin RD, 2016, AM J ROENTGENOL, DOI [10.2214/AJR.16.16387:1-9, DOI 10.2214/AJR.16.16387:1-9]
[4]   Sarcopenia: Current Concepts and Imaging Implications [J].
Boutin, Robert D. ;
Yao, Lawrence ;
Canter, Robert J. ;
Lenchik, Leon .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (03) :W255-W266
[5]   Regulation and Methylation of Tumor Suppressor MiR-124 by Androgen Receptor in Prostate Cancer Cells [J].
Chu, Mingliang ;
Chang, Yunli ;
Guo, Yanjing ;
Wang, Naitao ;
Cui, Jian ;
Gao, Wei-Qiang .
PLOS ONE, 2015, 10 (04)
[6]   The effect of late-phase contrast enhancement on semi-automatic software measurements of CT attenuation and volume of part-solid nodules in lung adenocarcinomas [J].
Cohen, Julien G. ;
Goo, Jin Mo ;
Yoo, Roh-Eul ;
Park, Su Bin ;
van Ginneken, Bram ;
Ferretti, Gilbert R. ;
Lee, Chang Hyun ;
Park, Chang Min .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (06) :1174-1180
[7]   Sarcopenia negatively affects preoperative total functional liver volume in patients undergoing liver resection [J].
Dello, Simon A. W. G. ;
Lodewick, Toine M. ;
van Dam, Ronald M. ;
Reisinger, Kostan W. ;
van den Broek, Maartje A. J. ;
von Meyenfeldt, Maarten F. ;
Bemelmans, Marc H. A. ;
Damink, Steven W. M. Olde ;
Dejong, Cornelis H. C. .
HPB, 2013, 15 (03) :165-169
[8]   Analytic Morphomics, Core Muscle Size, and Surgical Outcomes [J].
Englesbe, Michael J. ;
Lee, Jay S. ;
He, Kevin ;
Fan, Ludi ;
Schaubel, Douglas E. ;
Sheetz, Kyle H. ;
Harbaugh, Calista M. ;
Holcombe, Sven A. ;
Campbell, Darrel A., Jr. ;
Sonnenday, Christopher J. ;
Wang, Stewart C. .
ANNALS OF SURGERY, 2012, 256 (02) :255-261
[9]   Measuring Abdominal Circumference and Skeletal Muscle From a Single Cross-Sectional Computed Tomography Image: A Step-by-Step Guide for Clinicians Using National Institutes of Health ImageJ [J].
Gomez-Perez, Sandra L. ;
Haus, Jacob M. ;
Sheean, Patricia ;
Patel, Bimal ;
Mar, Winnie ;
Chaudhry, Vivek ;
McKeever, Liam ;
Braunschweig, Carol .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2016, 40 (03) :308-318
[10]   Skeletal muscle attenuation determined by computed tomography is associated with skeletal muscle lipid content [J].
Goodpaster, BH ;
Kelley, DE ;
Thaete, FL ;
He, J ;
Ross, R .
JOURNAL OF APPLIED PHYSIOLOGY, 2000, 89 (01) :104-110