Effect of cyclic loading protocols on the experimental seismic performance evaluation of suspended piping restraint installations

被引:20
作者
Filiatrault, Andre [1 ,2 ]
Perrone, Daniele [1 ]
Brunesi, Emanuele [3 ]
Beiter, Clemens [4 ]
Piccinin, Roberto [5 ]
机构
[1] Univ Sch Adv Studies IUSS Pavia, Palazzo Broletto,Piazza della Vittoria 15, I-27100 Pavia, Italy
[2] SUNY Buffalo, Buffalo, NY USA
[3] European Ctr Training & Res Earthquake Engn EUCtr, Via Adolfo Ferrata 1, I-27100 Pavia, Italy
[4] Hilti Corp, Business Unit Installat Syst, FL-9494 Schaan, Liechtenstein
[5] Hilti Corp, FL-9494 Schaan, Liechtenstein
关键词
Loading protocol; Non-structural elements; Seismic; Suspended piping; Restrain;
D O I
10.1016/j.ijpvp.2018.08.004
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Suspended non-structural elements, such as water and sprinkler piping systems, are key to the functionality of important facilities, such as hospitals and schools. Recent earthquakes have demonstrated the vulnerability of these systems, particularly for those that were inadequately restrained. Seismic qualification requirements of non-structural elements contained in recent building codes and industry standards rely on experimental procedures, such as quasi-static cyclic testing of components and sub-assemblies. When conducting such quasi-static testing, the question arises as to what proper loading protocol to use. The first part of this paper reviews and compare existing cyclic loading protocols for testing various types of components and sub-assembles and developed according to scientific methods, including two specifically developed for testing non-structural elements. These two non-structural loading protocols are then used for conducting quasi-static cyclic testing of common components part of piping restraint installations. Characteristic response parameters resulting from test results with each cyclic loading protocol are extracted and compared. Observations and recommendations are provided on the effects of using different cyclic loading protocols for the performance evaluation and seismic qualification testing of suspended piping restraint installations.
引用
收藏
页码:61 / 71
页数:11
相关论文
共 19 条
[1]  
Applied Technology Council (ATC), 1992, ATC-24
[2]  
ASCE, 2010, 710 ASCESEI, P656
[3]  
ASTM, 2003, 104985 ASTM INT
[4]  
Ayres J.M., 1996, Northridge Earthquake Hospital Water Damage Study
[5]  
CEN, 2004, 100252 DIN EN
[6]  
Chock G., 2006, Preliminary observations on the Hawaii earthquakes of October 15
[7]  
FEMA, 2011, P795 FEMA, P292
[8]  
FEMA, 2007, 461 FEMA, P138
[9]  
FM Approvals LLC, 2010, APPR STAND SEISM BRA, P25
[10]   Effects of loading protocol on the cyclic response of woodframe shearwalls [J].
Gatto, K ;
Uang, CM .
JOURNAL OF STRUCTURAL ENGINEERING, 2003, 129 (10) :1384-1393