Disagreement in cardiac output measurements between fourth-generation FloTrac and critical care ultrasonography in patients with circulatory shock: a prospective observational study

被引:6
作者
Kaufmann, Thomas [1 ]
Clement, Ramon P. [1 ]
Hiemstra, Bart [1 ,2 ]
Vos, Jaap Jan [1 ]
Scheeren, Thomas W. L. [1 ]
Keus, Frederik [2 ]
van der Horst, Iwan C. C. [2 ]
Koster, Geert
Keus, Frederik [2 ]
van der Horst, Iwan C. C. [2 ]
Dieperink, Willem
Bleijendaal, Roos
Cawale, Yasmin F.
Clement, Ramon P. [1 ]
Dijkhuizen, Devon
Eck, Ruben J.
Hiemstra, Bart [1 ,2 ]
Haker, Anja
Hilbink, Casper D. H.
Kaufmann, Thomas [1 ]
Klasen, Martiene
Klaver, Manon
Schokking, Laura J.
Sikkens, Victor W.
Vos, Madelon
Woerlee, Justin
Wiersema, Renske
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Anesthesiol, POB 30-001, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Crit Care, Groningen, Netherlands
关键词
Cardiac output; Critical care ultrasonography; Intensive care; Critically ill; Shock; Monitoring; Pulse contour analysis; ACUTE PHYSIOLOGY; STROKE VOLUME; ECHOCARDIOGRAPHY; MONITORS;
D O I
10.1186/s40560-019-0373-5
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Cardiac output measurements may inform diagnosis and provide guidance of therapeutic interventions in patients with hemodynamic instability. The FloTrac algorithm uses uncalibrated arterial pressure waveform analysis to estimate cardiac output. Recently, a new version of the algorithm has been developed. The aim was to assess the agreement between FloTrac and routinely performed cardiac output measurements obtained by critical care ultrasonography in patients with circulatory shock. Methods: A prospective observational study was performed in a tertiary hospital from June 2016 to January 2017. Adult critically ill patients with circulatory shock were eligible for inclusion. Cardiac output was measured simultaneously using FloTrac with a fourth-generation algorithm (COAP) and critical care ultrasonography (COCCUS). The strength of linear correlation of both methods was determined by the Pearson coefficient. Bland-Altman plot and four-quadrant plot were used to track agreement and trending ability. Result: Eighty-nine paired cardiac output measurements were performed in 17 patients during their first 24h of admittance. COAP and COCCUS had strong positive linear correlation (r(2)=0.60, p<0.001). Bias of COAP and COCCUS was 0.2 L min(-1) (95% CI - 0.2 to 0.6) with limits of agreement of - 3.6 L min(-1) (95% CI -4.3 to -2.9) to 4.0 L min(-1) (95% CI 3.3 to 4.7). The percentage error was 65.6% (95% CI 53.2 to 77.3). Concordance rate was 64.4%. Conclusions: In critically ill patients with circulatory shock, there was disagreement and clinically unacceptable trending ability between values of cardiac output obtained by uncalibrated arterial pressure waveform analysis and critical care ultrasonography.
引用
收藏
页数:8
相关论文
共 30 条
[21]  
Saugel B, 2018, MED KLIN-INTENSIVMED, V113, P192, DOI 10.1007/s00063-017-0302-0
[22]   Cardiac output monitoring: how to choose the optimal method for the individual patient [J].
Saugel, Bernd ;
Vincent, Jean-Louis .
CURRENT OPINION IN CRITICAL CARE, 2018, 24 (03) :165-172
[23]   Cardiac output monitoring: less invasiveness, less accuracy? [J].
Saugel, Bernd ;
Wagner, Julia Y. ;
Scheeren, Thomas W. L. .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (06) :753-755
[24]   Tracking Changes in Cardiac Output: Statistical Considerations on the 4-Quadrant Plot and the Polar Plot Methodology [J].
Saugel, Bernd ;
Grothe, Oliver ;
Wagner, Julia Y. .
ANESTHESIA AND ANALGESIA, 2015, 121 (02) :514-524
[25]   Systematic review of uncalibrated arterial pressure waveform analysis to determine cardiac output and stroke volume variation [J].
Slagt, C. ;
Malagon, I. ;
Groeneveld, A. B. J. .
BRITISH JOURNAL OF ANAESTHESIA, 2014, 112 (04) :626-637
[26]   Improved Performance of the Fourth-Generation FloTrac/Vigileo System for Tracking Cardiac Output Changes [J].
Suehiro, Koichi ;
Tanaka, Katsuaki ;
Mikawa, Mika ;
Uchihara, Yuriko ;
Matsuyama, Taiki ;
Matsuura, Tadashi ;
Funao, Tomoharu ;
Yamada, Tokuhiro ;
Mori, Takashi ;
Nishikawa, Kiyonobu .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (03) :656-662
[27]   Less invasive hemodynamic monitoring in critically ill patients [J].
Teboul, Jean-Louis ;
Saugel, Bernd ;
Cecconi, Maurizio ;
De Backer, Daniel ;
Hofer, Christoph K. ;
Monnet, Xavier ;
Perel, Azriel ;
Pinsky, Michael R. ;
Reuter, Daniel A. ;
Rhodes, Andrew ;
Squara, Pierre ;
Vincent, Jean-Louis ;
Scheeren, Thomas W. .
INTENSIVE CARE MEDICINE, 2016, 42 (09) :1350-1359
[28]   The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies [J].
von Elm, Erik ;
Altman, Douglas G. ;
Egger, Matthias ;
Pocock, Stuart J. ;
Gotzsche, Peter C. ;
Vandenbroucke, Jan P. .
LANCET, 2007, 370 (9596) :1453-1457
[29]   Systematic review of cardiac output measurements by echocardiography vs. thermodilution: the techniques are not interchangeable [J].
Wetterslev, Mik ;
Moller-Sorensen, Hasse ;
Johansen, Rasmus Rothmann ;
Perner, Anders .
INTENSIVE CARE MEDICINE, 2016, 42 (08) :1223-1233
[30]   Acute physiology and chronic health evaluation (APACHE) IV: Hospital mortality assessment for today's critically ill patients [J].
Zimmerman, JE ;
Kramer, AA ;
McNair, DS ;
Malila, FM .
CRITICAL CARE MEDICINE, 2006, 34 (05) :1297-1310