The dosimetric impact of intrafraction prostate motion was investigated for helical tomotherapy treatments. Measured motion tracks were used to calculate the dosimetric impact on delivered target dose distributions. A dynamic dose calculation engine was developed to facilitate this evaluation. It was found that the D-95% (minimum dose to 95% of the volume) changes in the prostate were well correlated with D-95% changes in the PTV. This means that the dosimetric impact of intrafraction motion is not restricted to the periphery of the target. The amount of motion was not well correlated with the dosimetric impact (measured in target D-95% changes) of motion. The relationship between motion and its dosimetric impact is complex and depends on the timing and direction of the movement. These findings have implications for motion management techniques. It appears that the use of target margins is not an effective strategy to protect the prostate from the effects of observed intrafraction motion. The complex relationship between motion and its dosimetric effect renders simple threshold-based intervention schemes inefficient. Monitoring of actual prostate motion would allow the documentation of the dosimetric impact and implementation of corrective action if needed. However, when motion management techniques are evaluated, it should be kept in mind that the dosimetric impact of observed prostate motion is small for the majority of fractions.
引用
收藏
页码:7073 / 7086
页数:14
相关论文
共 27 条
[1]   Accuracy of a wireless localization system for radiotherapy [J].
Balter, JM ;
Wright, JN ;
Newell, LJ ;
Friemel, B ;
Dimmer, S ;
Cheng, Y ;
Wong, J ;
Vertatschitsch, E ;
Mate, TP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03) :933-937
[2]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[3]   A comparison of ventilatory prostate movement in four treatment positions [J].
Dawson, LA ;
Litzenberg, DW ;
Brock, KK ;
Sanda, M ;
Sullivan, M ;
Sandler, HM ;
Balter, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02) :319-323
[4]   Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI) [J].
Ghilezan, MJ ;
Jaffray, DA ;
Siewerdsen, JH ;
van Herk, M ;
Shetty, A ;
Sharpe, MB ;
Jafri, SZ ;
Vicini, FA ;
Matter, RC ;
Brabbins, DS ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (02) :406-417
[5]   Intrafraction prostate motion during IMRT for prostate cancer [J].
Huang, E ;
Dong, L ;
Chandra, A ;
Kuban, DA ;
Rosen, II ;
Evans, A ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (02) :261-268
[6]   A motion phantom study on helical tomotherapy: the dosimetric impacts of delivery technique and motion [J].
Kanagaki, Brian ;
Read, Paul W. ;
Molloy, Janelle A. ;
Larner, James M. ;
Sheng, Ke .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (01) :243-255
[7]   Confirmation, refinement, and extension of a study in intrafraction motion interplay with sliding jaw motion [J].
Kissick, MW ;
Boswell, SA ;
Jeraj, R ;
Mackie, TR .
MEDICAL PHYSICS, 2005, 32 (07) :2346-2350
[8]   Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions [J].
Kitamura, K ;
Shirato, H ;
Seppenwoolde, Y ;
Onimaru, R ;
Oda, M ;
Fujita, K ;
Shimizu, S ;
Shinohara, N ;
Harabayashi, T ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1117-1123
[9]   Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy [J].
Kupelian, Patrick ;
Willoughby, Twyla ;
Mahadevan, Arul ;
Djemil, Toufik ;
Weinstein, Geoffrey ;
Jani, Shirish ;
Enke, Charles ;
Solberg, Timothy ;
Flores, Nicholas ;
Liu, David ;
Beyer, David ;
Levine, Lisa .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04) :1088-1098
[10]   Observations on real-time prostate gland motion using electromagnetic tracking [J].
Langen, Katja M. ;
Willoughby, Twyla R. ;
Meeks, Sanford L. ;
Santhanam, Anand ;
Cunningham, Alexis ;
Levine, Lisa ;
Kupelian, Patrick A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (04) :1084-1090