Optimization of the optical particle counter for online particle measurement in high-pressure gas

被引:6
作者
Lu, Lifeng [1 ,3 ]
Wu, Xiaolin [1 ,3 ]
Ji, Zhongli [2 ,3 ]
Xiong, Zhiyi [2 ,3 ]
Wang, Mingxing [1 ,3 ]
机构
[1] China Univ Petr, Dept Chem Engn, Beijing, Peoples R China
[2] China Univ Petr, Dept Mech & Transportat Engn, Beijing, Peoples R China
[3] China Univ Petr, Beijing Key Lab Proc Fluid Filtrat & Separat, Beijing, Peoples R China
关键词
SCATTERING SIZE ANALYSIS; MASS; CALIBRATION; AEROSOLS; SHAPE;
D O I
10.1364/AO.58.000308
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
With the aim to achieve fast and accurate online measurement of particle size and concentration in different high-pressure gas, the application of an optical particle counter (OPC) is extended from atmospheric pressure to high-pressure conditions (more than 2 MPa). But with the increase of the gas pressure, the performance of the OPC is reduced, resulting in the error of the tested particle size. In order to resolve this problem, an optimization model of optical window thickness is established for the optical sensor of the OPC based on the geometric optics theory. The effects of gas pressure, temperature, and medium on the optimized model are analyzed, which are helpful to improve the accuracy of the optical sensor. Finally, the feasibility, reliability, and accuracy of the method are verified through experiments. (C) 2019 Optical Society of America
引用
收藏
页码:308 / 316
页数:9
相关论文
共 50 条
[21]   Optical measurement method of non-spherical particle size and concentration based on high-temperature melting technique [J].
Lu, Lifeng ;
Wu, Xin ;
Chen, Lijun ;
Liu, Longlong ;
Li, Yanbo ;
Wang, Xiaorui .
MEASUREMENT, 2022, 198
[22]   Development of an optical time-resolved measurement system under high-pressure and low-temperature with a piston-cylinder pressure cell [J].
Tsuchiya, Satoshi ;
Kino, Yohei ;
Nakagawa, Koichi ;
Nakagawa, Daisuke ;
Yamada, Jun-ichi ;
Toda, Yasunori .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (04)
[23]   Hybrid 3D Dynamic Measurement by Particle Swarm Optimization and Photogrammetric Tracking [J].
Shahbazi, M. .
MEASUREMENT SCIENCE REVIEW, 2013, 13 (06) :298-304
[24]   Measurement Performance Evaluation of Tactile Pressure Sensor with Different Particle Sizes and Sensor Curvatures [J].
Liu, KaiYuan ;
Xu, ChengShun ;
Zhang, Xiaoling .
GEOTECHNICAL TESTING JOURNAL, 2021, 44 (04) :1036-1054
[25]   Influence of the particle morphology on the spray characteristics in low-pressure cold gas process [J].
Sinnwell, Yannik ;
Maksakov, Anton ;
Palis, Stefan ;
Antonyuk, Sergiy .
POWDER TECHNOLOGY, 2025, 464
[26]   Applying Pulse Height Analysis (PHA) Technique on an Optical Particle Counter (OPC) using Commercial ADC Module [J].
Hapidin, Dian Ahmad ;
Mustika, Widya Sinta ;
Saputra, Casmika ;
Maulana, Dian Syah ;
Khairurrijal, Khairurrijal ;
Iskandar, Ferry ;
Munir, Muhammad Miftahul .
MATERIALS TODAY-PROCEEDINGS, 2019, 13 :252-257
[27]   Applicability of the low-cost OPC-N3 optical particle counter for microphysical measurements of fog [J].
Nurowska, Katarzyna ;
Mohammadi, Moein ;
Malinowski, Szymon ;
Markowicz, Krzysztof .
ATMOSPHERIC MEASUREMENT TECHNIQUES, 2023, 16 (09) :2415-2430
[28]   Characteristics of critical nozzle flow meter for measuring high-pressure hydrogen gas [J].
Morioka T. ;
Nakao S.-I. ;
Ishibashi M. .
Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2011, 77 (776) :1088-1097
[29]   Development and evaluation of the calibration facility for high-pressure hydrogen gas flow meters [J].
Morioka, Toshihiro ;
Ito, Masaru ;
Fujikawa, Shizuichi ;
Ishibashi, Masahiro ;
Nakao, Shin-ichi .
FLOW MEASUREMENT AND INSTRUMENTATION, 2014, 39 :19-24
[30]   Optimization of the Measurement of Particle-Bound Reactive Oxygen Species with 2′,7′-dichlorofluorescin (DCFH) [J].
Huang, Wei ;
Zhang, Yuanxun ;
Zhang, Yang ;
Fang, Dongqing ;
Schauer, James J. .
WATER AIR AND SOIL POLLUTION, 2016, 227 (05)