Skin-Attachable, Stretchable Electrochemical Sweat Sensor for Glucose and pH Detection

被引:361
作者
Oh, Seung Yun [1 ]
Hong, Soo Yeong [2 ]
Jeong, Yu Ra [2 ]
Yun, Junyeong [2 ]
Park, Heun [2 ]
Jin, Sang Woo [1 ]
Lee, Geumbee [1 ]
Oh, Ju Hyun [2 ]
Lee, Hanchan [2 ]
Lee, Sang-Soo [1 ,3 ]
Ha, Jeong Sook [1 ,2 ]
机构
[1] Korea Univ, KU KIST Grad Sch Converging Sci & Technol, Seoul 02841, South Korea
[2] Korea Univ, Dept Chem & Biol Engn, Seoul 02841, South Korea
[3] Korea Inst Sci & Technol, Photoelect Hybrids Res Ctr, Seoul 02792, South Korea
基金
新加坡国家研究基金会;
关键词
stretchable electrochemical sensor; sweat sensor; wearable electronics; nanomaterial-based electrode; filtration; layer-by-layer; BLOOD-GLUCOSE; GRAPHENE FOAM; PERFORMANCE; ELECTRODE; SUPERCAPACITORS; FABRICATION; NANOSTRUCTURES; NANOPARTICLES; TRANSPARENT; NANOFIBERS;
D O I
10.1021/acsami.8b03342
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
As part of increased efforts to develop wearable healthcare devices for monitoring and managing physiological and metabolic information, stretchable electrochemical sweat sensors have been investigated. In this study, we report on the fabrication of a stretchable and skin-attachable electrochemical sensor for detecting glucose and pH in sweat. A patterned stretchable electrode was fabricated via layer-by-layer deposition of carbon nanotubes (CNTs) on top of patterned Au nanosheets (AuNS) prepared by filtration onto stretchable substrate. For the detection of glucose and pH, CoWO4/CNT and polyaniline/CNT nanocomposites were coated onto the CNT-AuNS electrodes, respectively. A reference electrode was prepared via chlorination of silver nanowires. Encapsulation of the stretchable sensor with sticky silbione led to a skin-attachable sweat sensor. Our sensor showed high performance with sensitivities of 10.89 mu A M-1 cm(-2) and 71.44 mV pH(-1) for glucose and pH, respectively, with mechanical stability up to 30% stretching and air stability for 10 days. The sensor also showed good adhesion even to wet skin, allowing the detection of glucose and pH in sweat from running while being attached onto the skin. This work suggests the application of our stretchable and skin-attachable electrochemical sensor to health management as a high-performance healthcare wearable device.
引用
收藏
页码:13729 / 13740
页数:12
相关论文
共 62 条
[1]   Highly Stretchable Fully-Printed CNT-Based Electrochemical Sensors and Biofuel Cells: Combining Intrinsic and Design-Induced Stretchability [J].
Bandodkar, Amay J. ;
Jeerapan, Itthipon ;
You, Jung-Min ;
Nunez-Flores, Rogelio ;
Wang, Joseph .
NANO LETTERS, 2016, 16 (01) :721-727
[2]   Non-invasive wearable electrochemical sensors: a review [J].
Bandodkar, Amay J. ;
Wang, Joseph .
TRENDS IN BIOTECHNOLOGY, 2014, 32 (07) :363-371
[3]   Epidermal tattoo potentiometric sodium sensors with wireless signal transduction for continuous non-invasive sweat monitoring [J].
Bandodkar, Amay J. ;
Molinnus, Denise ;
Mirza, Omar ;
Guinovart, Tomas ;
Windmiller, Joshua R. ;
Valdes-Ramirez, Gabriela ;
Andrade, Francisco J. ;
Schoening, Michael J. ;
Wang, Joseph .
BIOSENSORS & BIOELECTRONICS, 2014, 54 :603-609
[4]   Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring [J].
Bandodkar, Amay J. ;
Hung, Vinci W. S. ;
Jia, Wenzhao ;
Valdes-Ramirez, Gabriela ;
Windmiller, Joshua R. ;
Martinez, Alexandra G. ;
Ramirez, Julian ;
Chan, Garrett ;
Kerman, Kagan ;
Wang, Joseph .
ANALYST, 2013, 138 (01) :123-128
[5]   Development of an iridium-based pH sensor for bioanalytical applications [J].
Bause, S. ;
Decker, M. ;
Gerlach, F. ;
Naether, J. ;
Koster, F. ;
Neubauer, P. ;
Vonau, W. .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2018, 22 (01) :51-60
[6]   Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor [J].
Boyne, MS ;
Silver, DM ;
Kaplan, J ;
Saudek, CD .
DIABETES, 2003, 52 (11) :2790-2794
[7]   Co2SnO4 nanocrystals anchored on graphene sheets as high-performance electrodes for lithium-ion batteries [J].
Chen, Chang ;
Ru, Qiang ;
Hu, Shejun ;
An, Bonan ;
Song, Xiong ;
Hou, Xianhua .
ELECTROCHIMICA ACTA, 2015, 151 :203-213
[8]   Nonenzymatic electrochemical glucose sensor based on MnO2/MWNTs nanocomposite [J].
Chen, Jin ;
Zhang, Wei-De ;
Ye, Jian-Shan .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (09) :1268-1271
[9]   Transparent and Stretchable High-Performance Supercapacitors Based on Wrinkled Graphene Electrodes [J].
Chen, Tao ;
Xue, Yuhua ;
Roy, Ajit K. ;
Dai, Liming .
ACS NANO, 2014, 8 (01) :1039-1046
[10]   Nickel oxide hollow rnicrosphere for non-enzyme glucose detection [J].
Ci, Suqin ;
Huang, Taizhong ;
Wen, Zhenhai ;
Cui, Shumao ;
Mao, Shun ;
Steeber, Douglas A. ;
Chen, Junhong .
BIOSENSORS & BIOELECTRONICS, 2014, 54 :251-257