REFRACTIVE OUTCOMES AFTER SILICONE OIL REMOVAL AND INTRAOCULAR LENS IMPLANTATION

被引:10
作者
Suk, Kevin K. [1 ]
Smiddy, William E. [1 ]
Shi, Wei [1 ]
机构
[1] Bascom Palmer Eye Inst, Miami Miller Sch Med, Dept Ophthalmol, Miami, FL 33136 USA
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2013年 / 33卷 / 03期
关键词
accuracy; biometry; intraocular lens; intraocular lens implantation; IOLMaster; partial coherence interferometry; refractive outcome; silicone oil removal; ultrasound; PARTIAL COHERENCE INTERFEROMETRY; IMMERSION ULTRASOUND BIOMETRY; FILLED EYES; AXIAL LENGTH; PROLIFERATIVE VITREORETINOPATHY; OPTICAL BIOMETRY; COMBINED PHACOEMULSIFICATION; LASER INTERFEROMETRY; RETINAL-DETACHMENT; POWER CALCULATIONS;
D O I
10.1097/IAE.0b013e31826d37e4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the accuracy of intraocular lens (IOL) calculations in eyes undergoing silicone oil removal and IOL implantation using ultrasound biometry and partial coherence interferometry (PCI) (IOLMaster). Methods: This was a retrospective consecutive series of eyes that underwent silicone oil removal and IOL implantation from 1999 to 2009. Data were collected on preoperative and intraoperative characteristics that could affect the refractive outcome. The predicted refraction, as measured with ultrasound biometry or PCI, was compared with the postoperative refraction. Results: Overall, the mean difference between observed and predicted refraction was -0.97 diopters (D). Thirty-five of 64 eyes (55%) were measured by ultrasound biometry, and 29 of 64 eyes (45%) were measured by PCI. The mean (SD) difference between the predicted refraction and the observed spherical equivalent was -1.34 D (2.18 D) when measured by biometry and -0.51 D (2.03 D) when measured by PCI (P = 0.13). Conclusion: Refractive outcomes after silicone oil removal and secondary IOL implantation are fairly accurate, with most ending up slightly myopic. Measurement by PCI may be more accurate than biometry. The IOL power should be selected to yield a target refraction about 0.5 D to 1.25 D more hyperopic than desired, depending on the method used to measure it. RETINA 33:634-641, 2013
引用
收藏
页码:634 / 641
页数:8
相关论文
共 49 条
[31]   Recurrent retinal detachment: does initial treatment matter? [J].
Mansouri, A. ;
Almony, A. ;
Shah, G. K. ;
Blinder, K. J. ;
Sharma, S. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (10) :1344-1347
[32]   Optical biometry in combined phacovitrectomy [J].
Manvikar, Sridhar R. ;
Allen, David ;
Steel, David H. W. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) :64-69
[33]   Biometry of the silicone oil-filled eye: II [J].
Murray, DC ;
Durrani, OM ;
Good, P ;
Benson, MT ;
Kirkby, GR .
EYE, 2002, 16 (06) :727-730
[34]   Biometry and refractive outcome of eyes filled with silicone oil by standardized echography and partial coherence interferometry [J].
Nepp, J ;
Krepler, K ;
Jandrasits, K ;
Hauff, W ;
Hanselmayer, G ;
Velikay-Parel, M ;
Ossoinig, KC ;
Wedrich, A .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 243 (10) :967-972
[35]   SOURCES OF ERROR IN INTRAOCULAR-LENS POWER CALCULATION [J].
OLSEN, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (02) :125-129
[37]   Calculation of intraocular lens power: a review [J].
Olsen, Thomas .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (05) :472-485
[38]   Reliability of the IOLMaster in axial length evaluation in silicone oil-filled eyes [J].
Parravano, M. ;
Oddone, F. ;
Sampalmieri, M. ;
Gazzaniga, D. .
EYE, 2007, 21 (07) :909-911
[39]   Intraoperative retinoscopy for intraocular lens power estimation in cases of combined phacoemulsification and silicone oil removal [J].
Patwardhan, Sourabh D. ;
Azad, Rajvardhan ;
Sharma, Yograj ;
Chanana, Bhuvan ;
Tyagi, Jaideep .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07) :1190-1192
[40]   PHOTOCOAGULATION FOR DIABETIC MACULAR EDEMA - EARLY TREATMENT DIABETIC-RETINOPATHY STUDY REPORT 1. EARLY TREATMENT DIABETIC RETINOPATHY STUDY RESEARCH GROUP [J].
PATZ, A ;
RICE, TA ;
MURPHY, RP ;
NEWSOME, DA ;
SHERMAN, SH ;
FINE, SL ;
AIELLO, LM ;
RAND, LI ;
BRIONES, JC ;
SHAH, ST ;
MYERS, FL ;
BRESNICK, GH ;
DAVIS, MD ;
CHANDRA, SR ;
WALLOW, IHL ;
STEVENS, TS ;
KLEIN, R ;
FLYNN, HW ;
BLANKENSHIP, GW ;
KNOBLOCH, WH ;
RAMSAY, RC ;
CANTRILL, HL ;
HODGKINSON, BJ ;
RYAN, SJ ;
LIANG, JC ;
THOMAS, EL ;
KLEIN, ML ;
HANDELMAN, IL ;
SIPPERLEY, JO ;
CHENOWETH, RG ;
ERNEST, JT ;
LIANG, JC ;
CUNHA-VAZ, J ;
GOLDBERG, MF ;
LINDBERG, CR ;
VYGANTAS, C ;
KLEIN, HJ ;
BLAIR, N ;
REDNAM, K ;
KOPELOW, SM ;
SHABO, AL ;
STRAATSMA, BR ;
BRIONES, JC ;
KASSOFF, A ;
LITTLE, HL ;
JACK, RL ;
CAVENDER, JC ;
AI, E ;
SORENSON, RL ;
TASMAN, WS .
ARCHIVES OF OPHTHALMOLOGY, 1985, 103 (12) :1796-1806