REFRACTIVE OUTCOMES AFTER SILICONE OIL REMOVAL AND INTRAOCULAR LENS IMPLANTATION

被引:10
作者
Suk, Kevin K. [1 ]
Smiddy, William E. [1 ]
Shi, Wei [1 ]
机构
[1] Bascom Palmer Eye Inst, Miami Miller Sch Med, Dept Ophthalmol, Miami, FL 33136 USA
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2013年 / 33卷 / 03期
关键词
accuracy; biometry; intraocular lens; intraocular lens implantation; IOLMaster; partial coherence interferometry; refractive outcome; silicone oil removal; ultrasound; PARTIAL COHERENCE INTERFEROMETRY; IMMERSION ULTRASOUND BIOMETRY; FILLED EYES; AXIAL LENGTH; PROLIFERATIVE VITREORETINOPATHY; OPTICAL BIOMETRY; COMBINED PHACOEMULSIFICATION; LASER INTERFEROMETRY; RETINAL-DETACHMENT; POWER CALCULATIONS;
D O I
10.1097/IAE.0b013e31826d37e4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the accuracy of intraocular lens (IOL) calculations in eyes undergoing silicone oil removal and IOL implantation using ultrasound biometry and partial coherence interferometry (PCI) (IOLMaster). Methods: This was a retrospective consecutive series of eyes that underwent silicone oil removal and IOL implantation from 1999 to 2009. Data were collected on preoperative and intraoperative characteristics that could affect the refractive outcome. The predicted refraction, as measured with ultrasound biometry or PCI, was compared with the postoperative refraction. Results: Overall, the mean difference between observed and predicted refraction was -0.97 diopters (D). Thirty-five of 64 eyes (55%) were measured by ultrasound biometry, and 29 of 64 eyes (45%) were measured by PCI. The mean (SD) difference between the predicted refraction and the observed spherical equivalent was -1.34 D (2.18 D) when measured by biometry and -0.51 D (2.03 D) when measured by PCI (P = 0.13). Conclusion: Refractive outcomes after silicone oil removal and secondary IOL implantation are fairly accurate, with most ending up slightly myopic. Measurement by PCI may be more accurate than biometry. The IOL power should be selected to yield a target refraction about 0.5 D to 1.25 D more hyperopic than desired, depending on the method used to measure it. RETINA 33:634-641, 2013
引用
收藏
页码:634 / 641
页数:8
相关论文
共 49 条
[1]   Vitrectomy with silicone oil or long-acting gas in eyes with severe proliferative vitreoretinopathy: Results of additional and long-term follow-up - Silicone study report 11 [J].
Abrams, GW ;
Azen, SP ;
McCuen, BW ;
Flynn, HW ;
Lai, MY ;
Ryan, SJ .
ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (03) :335-344
[2]   Combined phacoemulsification and transpupillary drainage of silicone oil: results and complications [J].
Assi, A ;
Woodruff, S ;
Gotzaridis, E ;
Bunce, C ;
Sullivan, P .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (08) :942-945
[3]   Accuracy of Intraocular Lens Calculations Using the IOLMaster in Eyes with Long Axial Length and a Comparison of Various Formulas [J].
Bang, Stacy ;
Edell, Erica ;
Yu, Qilu ;
Pratzer, Kim ;
Stark, Walter .
OPHTHALMOLOGY, 2011, 118 (03) :503-506
[4]   Comparison of A-scan and MRI for the measurement of axial length in silicone oil-filled eyes [J].
Bencic, G. ;
Vatavuk, Z. ;
Marotti, M. ;
Loncar, V. L. ;
Petric, I. ;
Andrijevic-Derk, B. ;
Skunca, J. ;
Mandic, Z. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (04) :502-505
[5]   Comparison of predictions made by the Intraocular Lens Master and ultrasound biometry [J].
Bhatt, Anand B. ;
Schefler, Amy C. ;
Feuer, William J. ;
Yoo, Sonia H. ;
Murray, Timothy G. .
ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (07) :929-933
[6]   MACULAR CHANGES AND FLUORESCEIN ANGIOGRAPHIC FINDINGS AFTER REPAIR OF PROLIFERATIVE VITREORETINOPATHY [J].
BONNET, M .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1994, 14 (05) :404-410
[7]   Refractive change following pseudophakic vitrectomy [J].
Byrne, Sinead ;
Ng, James ;
Hildreth, Anthony ;
Danjoux, Jean-Pierre ;
Steel, David H. W. .
BMC OPHTHALMOLOGY, 2008, 8 (1)
[8]   The effect of scleral buckling surgery on corneal astigmatism, corneal thickness, and anterior chamber depth [J].
Cetin, E ;
Ozbek, Z ;
Saatci, O ;
Durak, I .
JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (05) :494-499
[9]  
CRISP A, 1987, ARCH OPHTHALMOL-CHIC, V105, P546
[10]   Effect of head position on refraction in aphakic and phakic silicone-filled eyes [J].
Dick, HB ;
Schwenn, O ;
Pavlovic, S ;
Jacobi, FK ;
Pfeiffer, N .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1997, 17 (05) :397-402