Patient satisfaction and masticatory efficiency of single implant-retained mandibular overdentures using the stud and magnetic attachments

被引:82
作者
Cheng, Tao [1 ,2 ,3 ]
Sun, Guifeng [2 ]
Huo, Jingyu [2 ]
He, Xiaoji [2 ]
Wang, Yining [1 ]
Ren, Yan-Fang [3 ,4 ]
机构
[1] Wuhan Univ, Sch Stomatol, Wuhan 430079, Hubei, Peoples R China
[2] Zhengzhou Hosp Stomatol, Zhengzhou, Henan, Peoples R China
[3] Zhengzhou Univ, Sch Stomatol, Zhengzhou, Henan, Peoples R China
[4] Univ Rochester, Eastman Inst Oral Hlth, Rochester, NY USA
关键词
Dental implant; Overdenture; Patient satisfaction; Clinical trial; Crossover design; SUPPORTED OVERDENTURES; EDENTULOUS PATIENTS; CLINICAL-TRIAL; IN-VITRO; BALL; SYSTEMS; DENTURES; STRESS;
D O I
10.1016/j.jdent.2012.08.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To study patient satisfaction and masticatory efficiency of single implant-retained mandibular overdentures using the stud and magnetic attachments in a randomized clinical trial with a crossover design. Methods: Patients received a single implant placed in the midline of the mandible and either a stud (Locator) or a magnetic (Magfit) attachment, assigned at random. Patient satisfaction, including patient comfort, speech, chewing ability and retention, and masticatory efficiency measured by chewing peanuts, were assessed before and 3 months after attachment insertion. Patient satisfaction and masticatory efficiency were evaluated again 3 months after insertion of the alternate attachment bodies. The outcomes were compared before and after insertion of the attachments and between the two types of attachments using Wilcoxon signed rank tests. Results: Patient overall satisfaction, comfort, speech, chewing ability, and retention improved significantly after insertion of both types of attachment bodies (p < 0.05). Masticatory efficiencies also increased in both the Locator and the Magfit groups (p < 0.05). There were no statistically significant differences in patient overall satisfaction, comfort, speech, and retention between the two types of attachments (p > 0.05). The Locator attachments performed better in perceived chewing ability than the Magfit (p < 0.05), but there was no statistically significant difference in masticatory efficiency between the two attachment types (p > 0.05). Conclusions: Clinical outcomes were significantly improved in single implant-retained mandibular overdentures using either the Locator or the Magfit magnetic attachments. There was no difference in masticatory efficiency between the two attachment types. (c) 2012 Ltd. All rights reserved.
引用
收藏
页码:1018 / 1023
页数:6
相关论文
共 28 条
[1]   EVALUATION OF THE ATTRACTIVE FORCE OF DIFFERENT TYPES OF NEW-GENERATION MAGNETIC ATTACHMENT SYSTEMS [J].
Akin, Hakan ;
Coskun, M. Emre ;
Akin, E. Gulsah ;
Ozdemir, A. Kemal .
JOURNAL OF PROSTHETIC DENTISTRY, 2011, 105 (03) :203-207
[2]   Mandibular single-implant overdentures: a review with surgical and prosthodontic perspectives of a novel approach [J].
Alsabeeha, Nabeel ;
Payne, Alan G. T. ;
De Silva, Rohana K. ;
Swain, Michael V. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (04) :356-365
[3]  
Alsabeeha NHM, 2011, INT J PROSTHODONT, V24, P247
[4]   Mandibular single-implant overdentures: preliminary results of a randomised-control trial on early loading with different implant diameters and attachment systems [J].
Alsabeeha, Nabeel H. M. ;
Payne, Alan G. T. ;
De Silva, Rohana K. ;
Thomson, W. Murray .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (03) :330-337
[5]  
Assad AS, 2004, IMPLANT DENT, V13
[6]   Resistance to Wear of Four Matrices with Ball Attachments for Implant Overdentures: A Fatigue Study [J].
Branchi, Roberto ;
Vangi, Dario ;
Virga, Antonio ;
Guertin, Genevieve ;
Fazi, Giovanni .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (08) :31-36
[7]  
Çehreli MC, 2010, INT J ORAL MAX IMPL, V25, P163
[8]  
Cheng T., 2012, J Dent Sci
[9]  
Chung Kwok-Hung, 2004, J Prosthodont, V13, P221
[10]   Mandibular overdentures anchored to single implants: A five-year prospective study [J].
Cordioli, C ;
Majzoub, Z ;
Castagna, S .
JOURNAL OF PROSTHETIC DENTISTRY, 1997, 78 (02) :159-165