The Influence of Kraft Papers and Mica Insertion on the Insulator Leakage Current of Coaxial Electrodes

被引:0
作者
Suyono, Hadi [1 ]
Dhofir, Moch [1 ]
Hasanah, Rini Nur [1 ]
Agustina, Rifka [1 ]
Dwiferma, Sinta [1 ]
机构
[1] Brawijaya Univ, Fac Engn, Elect Engn Dept, Malang, Indonesia
来源
2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE) | 2018年
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The insertion of mica barrier between coaxial electrodes results in a larger reduction of leakage current than the use of kraft paper insertion. The reduction is influenced by the barrier position and the testing voltage level. When using the kraft paper, there is a certain voltage level beyond which the characteristic of leakage current as a function of barrier position is relatively the image of that under the voltage level. At this level, the leakage current is almost the same wherever the barrier position. The use of mica insertion tends to shift the symmetry axis of the characteristic curves, meaning higher leakage current level.
引用
收藏
页数:4
相关论文
共 14 条
[1]  
[Anonymous], 1922, J I ELECT ENG LOND, V60, P339
[2]  
[Anonymous], 1978, INTRO HIGH VOLTAGE E
[3]  
[Anonymous], 2000, HIGH VOLTAGE ENG FUN
[4]  
Arora R, 2011, HIGH VOLTAGE AND ELECTRICAL INSULATION ENGINEERING, P1, DOI 10.1002/9780470947906
[5]  
Dhofir M., 2017, Int. J. Adv. Sci., Eng. Inf. Technol., V7, P1340, DOI [10.18517/ijaseit.7.4.3134, DOI 10.18517/IJASEIT.7.4.3134]
[6]  
Fleming R. T., 1921, J I ELECT ENG LOND, V60, P58
[7]  
Gavrila DE, 1998, PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN SOLID DIELECTRICS - ICSD '98, P214
[8]  
Griffeth R. L., 1952, ELECTRON ENG, V71, P463
[9]  
Holé S, 2017, 2017 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM), VOLS 1 & 2, P107, DOI 10.23919/ISEIM.2017.8088700
[10]  
Kind D., 1985, High-voltage insulation technology: textbook for electrical engineers