Influence of Accelerometer Placement and/or Heart Rate on Energy Expenditure Prediction during Uphill Exercise

被引:18
作者
Kuo, Terry B. J. [1 ,2 ,3 ,4 ,5 ,6 ]
Li, Jia-Yi [1 ,2 ,7 ]
Chen, Chung-Yu [2 ,5 ]
Lin, Yu-Cheng [1 ,2 ]
Tsai, Mei-Wun [8 ]
Lin, Shun-Ping [9 ]
Yang, Cheryl C. H. [1 ,2 ,3 ,4 ]
机构
[1] Natl Yang Ming Univ, Inst Brain Sci, 155,Sec 2,Li Nong St, Taipei 11221, Taiwan
[2] Natl Yang Ming Univ, Sleep Res Ctr, Taipei, Taiwan
[3] Taipei City Hosp, Dept Educ & Res, Taipei, Taiwan
[4] Natl Yang Ming Univ, Brain Res Ctr, Taipei, Taiwan
[5] Natl Yang Ming Univ, Inst Biophoton, Taipei, Taiwan
[6] Natl Cent Univ, Inst Translat & Interdisciplinary Med, Taoyuan, Taiwan
[7] Yuanpei Univ Med Technol, Dept Hlth & Leisure Management, Hsinchu, Taiwan
[8] Natl Yang Ming Univ, Dept Phys Therapy & Assist Technol, Taipei, Taiwan
[9] China Univ Sci & Technol, Phys Educ Off, Taipei, Taiwan
关键词
energy expenditure; heart rate; triaxial accelerometer; uphill exercise; DAILY PHYSICAL-ACTIVITY; WALKING; COST; INTENSITY; SLOPES;
D O I
10.1080/00222895.2017.1306481
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Studies using a triaxial accelerometer and heart rate (HR) simultaneously for estimating energy expenditure (EE) during uphill exercise are rare. Exploring the optimal location for placing the accelerometer for predicting EE during uphill exercise is essential. Sixteen healthy male participants (M +/- SEM; age 25.00 +/- 0.61 years; body weight 74.13 +/- 2.51 kg; body height 1.74 +/- 0.01 m; body mass index 24.30 +/- 0.63 kg/m(2)) exercised on a treadmill under 12 conditions (4 speeds and 3 gradients) on 3days. Triaxial accelerometers, an HR recorder, and a metabolic measurement system were simultaneously used. Accelerometer outputs from various anatomical locations (upper arm, chest, lower back, waist, thigh, and instep) showed significant positive correlations with EE (0.819, 0.846, 0.816, 0.820, 0.672, and 0.669, respectively; p < .05). The linear regression equation for changes in HR showed the highest coefficient of determination (r(2)) of .837 with 87.9% reliability. When the HR signal was included, the r(2) value (> .842) and reliability (87.9%) between the accelerometer outputs and EE improved. Accelerometer outputs from the waist position alone provide highly accurate EE values. Using both accelerometer outputs and HR for EE estimation during uphill exercise is feasible and improves the accuracy of EE prediction.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 28 条
  • [1] Personalized Preventive Medicine: Genetics and the Response to Regular Exercise in Preventive Interventionse
    Bouchard, Claude
    Antunes-Correa, Ligia M.
    Ashley, Euan A.
    Franklin, Nina
    Hwang, Paul M.
    Mattsson, C. Mikael
    Negrao, Carlos E.
    Phillips, Shane A.
    Sarzynski, Mark A.
    Wang, Ping-yuan
    Wheeler, Matthew T.
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 2015, 57 (04) : 337 - 346
  • [2] A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity
    Bouten, CVC
    Koekkoek, KTM
    Verduin, M
    Kodde, R
    Janssen, JD
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (03) : 136 - 147
  • [3] Branched equation modeling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditure
    Brage, S
    Brage, N
    Franks, PW
    Ekelund, U
    Wong, MY
    Andersen, LB
    Froberg, K
    Wareham, NJ
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (01) : 343 - 351
  • [4] Crocq Marc-Antoine, 2003, Dialogues Clin Neurosci, V5, P175
  • [5] Accuracy of polar S410 heart rate monitor to estimate energy cost of exercise
    Crouter, SE
    Albright, C
    Bassett, DR
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (08) : 1433 - 1439
  • [6] Objective monitoring of physical activity using motion sensors and heart rate
    Freedson, PS
    Miller, K
    [J]. RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2000, 71 (02) : S21 - S29
  • [7] Hsieh I. T., 2012, 2012 IEEE SENS C TAI
  • [8] HEART-RATE AND EXERCISE INTENSITY DURING SPORTS ACTIVITIES - PRACTICAL APPLICATION
    KARVONEN, J
    VUORIMAA, T
    [J]. SPORTS MEDICINE, 1988, 5 (05) : 303 - 311
  • [9] Prediction of energy expenditure from heart rate monitoring during submaximal exercise
    Keytel, LR
    Goedecke, JH
    Noakes, TD
    Hiiloskorpi, H
    Laukkanen, R
    Van der Merwe, L
    Lambert, EV
    [J]. JOURNAL OF SPORTS SCIENCES, 2005, 23 (03) : 289 - 297
  • [10] Effects of cold exposure on autonomic changes during the last rapid eye movement sleep transition and morning blood pressure surge in humans
    Kuo, Terry B. J.
    Hong, Cian-Hui
    Hsieh, I-Te
    Lee, Guo-She
    Yang, Cheryl C. H.
    [J]. SLEEP MEDICINE, 2014, 15 (08) : 986 - 997