Optimization of Measurement Arrangements for Magnetic Detection Electrical Impedance Tomography

被引:10
|
作者
Hao, Liling [1 ,2 ]
Li, Gang [3 ]
Lin, Ling [4 ]
机构
[1] Tianjin Univ, Coll Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
[2] Northeastern Univ, Dept SINO DUTCH Biomed & Informat Engn, Shenyang 110819, Liaoning, Peoples R China
[3] Tianjin Univ, Tianjin Key Lab Biomed Detecting Tech & Instrumen, Tianjin 300072, Peoples R China
[4] Tianjin Univ, State Key Lab Precis Measurement Technol & Instru, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic detection electrical impedance tomography (MDEIT); optimum measurement arrangement; redundancy reduction; region of interest (RoI); singular value analysis (SVA); IMAGE-RECONSTRUCTION;
D O I
10.1109/TBME.2013.2280632
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic detection electrical impedance tomography (MDEIT) is an imaging modality that aims to compute the cross-sectional distribution of the conductivity inside a volume. The current is injected into the volume by the surface electrodes and the resulting magnetic fields surrounding the object are detected by coils. The image resolution and contrast in MDEIT image reconstruction are affected by the parameters such as the numbers and locations of electrodes and measurements, and the finite-element mesh resolution. This paper addresses the numerical experiment applied to the singular value analysis (SVA) of the sensitivity matrix in the presence of noisy measurements, subsequently suggesting the optimal electrode and detector configurations for the whole imaging object region. For the region of interest (RoI), the combined SVA and redundancy reduction is used to obtain the optimum measurement arrangement. Finally, the optimum design is confirmed by examining the image reconstructions of the simulated data acquired with different measurement arrangements. The results indicate that properly increasing the number of current injections and the number of measurement circles, and locating preferentially the electrodes and detectors on the region nearest to the RoI produce more useful singular values and better reconstructed images. These results provide guidelines for the design of the MDEIT experimental system.
引用
收藏
页码:444 / 452
页数:9
相关论文
共 50 条
  • [41] Coregistration of electrical impedance tomography and magnetic resonance imaging
    Halter, R. J.
    Manwaring, P.
    Hartov, A.
    Paulsen, K. D.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 416 - 419
  • [42] Apple bruise detection by electrical impedance measurement
    Jackson, PJ
    Harker, FR
    HORTSCIENCE, 2000, 35 (01) : 104 - 107
  • [43] Apple Bruise Detection by Electrical Impedance Measurement
    Jackson, Phillipa J.
    Harker, F. Roger
    Hortscience: A Publication of the American Society for Hortcultural Science, 2000, 35 (01): : 104 - 107
  • [44] Electrical conductivity imaging by magnetic resonance electrical impedance tomography (MREIT)
    Oh, SH
    Han, JY
    Lee, SY
    Cho, MH
    Lee, BI
    Woo, EJ
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (04) : 875 - 878
  • [45] DETECTION OF GASTROESOPHAGEAL REFLUX BY ELECTRICAL-IMPEDANCE TOMOGRAPHY
    RAVELLI, AM
    MILLA, PJ
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1994, 18 (02): : 205 - 213
  • [46] Optimized breath detection algorithm in electrical impedance tomography
    Khodadad, D.
    Nordebo, S.
    Muller, B.
    Waldmann, A.
    Yerworth, R.
    Becher, T.
    Frerichs, I
    Sophodeous, L.
    Van Kaam, A.
    Miedema, M.
    Seifnaraghi, N.
    Bayford, R.
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (09)
  • [47] Detection of Pressure Ulcers Using Electrical Impedance Tomography
    Liu, Saiqiang
    Xu, Yanbin
    Chen, Sitong
    Hu, Qingwei
    Dong, Feng
    2022 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2022), 2022,
  • [48] Detection of small bleeds in the brain with electrical impedance tomography
    Boverman, Gregory
    Kao, Tzu-Jen
    Wang, Xin
    Ashe, Jeffrey M.
    Davenport, David M.
    Amm, Bruce C.
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (06) : 727 - 750
  • [49] Detection of Multicomponent Distribution by Electrical Impedance Spectroscopic Tomography
    Yao, Wang
    Zhao, Tong
    Liu, Xiayi
    Wang, Zhilong
    Li, Yiduo
    Miao, Li
    TWELFTH INTERNATIONAL CONFERENCE ON GRAPHICS AND IMAGE PROCESSING (ICGIP 2020), 2021, 11720
  • [50] Detection of Vesicoureteral Reflux Using Electrical Impedance Tomography
    Dunne, Eoghan
    O'Halloran, Martin
    Craven, Darren
    Puri, Prem
    Frehill, Paul
    Loughney, Sarah
    Porter, Emily
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (08) : 2279 - 2286