Optimization of Measurement Arrangements for Magnetic Detection Electrical Impedance Tomography

被引:10
|
作者
Hao, Liling [1 ,2 ]
Li, Gang [3 ]
Lin, Ling [4 ]
机构
[1] Tianjin Univ, Coll Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
[2] Northeastern Univ, Dept SINO DUTCH Biomed & Informat Engn, Shenyang 110819, Liaoning, Peoples R China
[3] Tianjin Univ, Tianjin Key Lab Biomed Detecting Tech & Instrumen, Tianjin 300072, Peoples R China
[4] Tianjin Univ, State Key Lab Precis Measurement Technol & Instru, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic detection electrical impedance tomography (MDEIT); optimum measurement arrangement; redundancy reduction; region of interest (RoI); singular value analysis (SVA); IMAGE-RECONSTRUCTION;
D O I
10.1109/TBME.2013.2280632
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic detection electrical impedance tomography (MDEIT) is an imaging modality that aims to compute the cross-sectional distribution of the conductivity inside a volume. The current is injected into the volume by the surface electrodes and the resulting magnetic fields surrounding the object are detected by coils. The image resolution and contrast in MDEIT image reconstruction are affected by the parameters such as the numbers and locations of electrodes and measurements, and the finite-element mesh resolution. This paper addresses the numerical experiment applied to the singular value analysis (SVA) of the sensitivity matrix in the presence of noisy measurements, subsequently suggesting the optimal electrode and detector configurations for the whole imaging object region. For the region of interest (RoI), the combined SVA and redundancy reduction is used to obtain the optimum measurement arrangement. Finally, the optimum design is confirmed by examining the image reconstructions of the simulated data acquired with different measurement arrangements. The results indicate that properly increasing the number of current injections and the number of measurement circles, and locating preferentially the electrodes and detectors on the region nearest to the RoI produce more useful singular values and better reconstructed images. These results provide guidelines for the design of the MDEIT experimental system.
引用
收藏
页码:444 / 452
页数:9
相关论文
共 50 条
  • [11] Domain Shape Optimization in Electrical Impedance Tomography
    Mikulka, J.
    Dusek, J.
    Chalupa, D.
    2021 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS 2021), 2021, : 2155 - 2159
  • [12] A global optimization approach to electrical impedance tomography
    Yang, LX
    Truyen, B
    Cornelis, J
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 437 - 440
  • [13] Unsupervised Evaluation and Optimization for Electrical Impedance Tomography
    Wang, Zeying
    Yue, Shihong
    Li, Qi
    Liu, Xiaoyuan
    Wang, Huaxiang
    McEwan, Alistair
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [14] Optimization of Electrode Positions in Electrical Impedance Tomography
    Dusek, J.
    Mikulka, J.
    2021 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS 2021), 2021, : 2183 - 2188
  • [15] The Feasibility of Fast Neural Magnetic Detection Electrical Impedance Tomography: A Modelling Study
    Mason, Kai
    Aristovich, Kirill
    Holder, David
    2023 11TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING, NER, 2023,
  • [16] A feasibility study of magnetic resonance electrical impedance tomography for prostate cancer detection
    Liu, Yang
    Zhang, Yingchun
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (04) : 567 - 581
  • [17] Research on Magnetic Detection Electrical Impedance Tomography System Based on Scanning Platform
    Chen, Ruijuan
    Li, Bingnan
    Li, Fang
    Wang, Huiquan
    Wang, Jinhai
    2018 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND BIOINFORMATICS (ICBEB 2018), 2018, : 36 - 41
  • [18] Research on magnetic detection electrical impedance tomography based on structural prior information
    Chen R.
    Wu W.
    Li F.
    Wang H.
    Wang Y.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2020, 41 (05): : 196 - 204
  • [19] Optimisation of magnetic field sensing with optically pumped magnetometers for magnetic detection electrical impedance tomography
    Mason, Kai
    Maurino-Alperovich, Florencia
    Aristovich, Kirill
    Holder, David
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (07):
  • [20] Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Seo, Jin Keun
    Woo, Eung Je
    SIAM REVIEW, 2011, 53 (01) : 40 - 68