Optimization of Measurement Arrangements for Magnetic Detection Electrical Impedance Tomography

被引:10
|
作者
Hao, Liling [1 ,2 ]
Li, Gang [3 ]
Lin, Ling [4 ]
机构
[1] Tianjin Univ, Coll Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
[2] Northeastern Univ, Dept SINO DUTCH Biomed & Informat Engn, Shenyang 110819, Liaoning, Peoples R China
[3] Tianjin Univ, Tianjin Key Lab Biomed Detecting Tech & Instrumen, Tianjin 300072, Peoples R China
[4] Tianjin Univ, State Key Lab Precis Measurement Technol & Instru, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic detection electrical impedance tomography (MDEIT); optimum measurement arrangement; redundancy reduction; region of interest (RoI); singular value analysis (SVA); IMAGE-RECONSTRUCTION;
D O I
10.1109/TBME.2013.2280632
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic detection electrical impedance tomography (MDEIT) is an imaging modality that aims to compute the cross-sectional distribution of the conductivity inside a volume. The current is injected into the volume by the surface electrodes and the resulting magnetic fields surrounding the object are detected by coils. The image resolution and contrast in MDEIT image reconstruction are affected by the parameters such as the numbers and locations of electrodes and measurements, and the finite-element mesh resolution. This paper addresses the numerical experiment applied to the singular value analysis (SVA) of the sensitivity matrix in the presence of noisy measurements, subsequently suggesting the optimal electrode and detector configurations for the whole imaging object region. For the region of interest (RoI), the combined SVA and redundancy reduction is used to obtain the optimum measurement arrangement. Finally, the optimum design is confirmed by examining the image reconstructions of the simulated data acquired with different measurement arrangements. The results indicate that properly increasing the number of current injections and the number of measurement circles, and locating preferentially the electrodes and detectors on the region nearest to the RoI produce more useful singular values and better reconstructed images. These results provide guidelines for the design of the MDEIT experimental system.
引用
收藏
页码:444 / 452
页数:9
相关论文
共 50 条
  • [1] Constrained image reconstruction for magnetic detection electrical impedance tomography
    Ireland, Rob H.
    Barber, David C.
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2007, 17 (06) : 379 - 382
  • [2] Magnetic detection electrical impedance tomography with total variation regularization
    Hao, Liling
    Li, Gang
    Xu, Lisheng
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (06) : 2857 - 2864
  • [3] Measurement of ion diffusion using magnetic resonance electrical impedance tomography
    Hamamura, Mark J.
    Muftuler, L. Tugan
    Birgul, Ozlem
    Nalcioglu, Orhan
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (11): : 2753 - 2762
  • [4] A Measurement System for Electrical Impedance Tomography
    Kriz, T.
    Roubal, Z.
    Rez, J.
    PIERS 2013 STOCKHOLM: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, 2013, : 905 - 909
  • [5] Multi-frequency Electrical Impedance Tomography and Magnetic Resonance Electrical Impedance Tomography
    Seo, Jin Keun
    Woo, Eung Je
    MATHEMATICAL MODELING IN BIOMEDICAL IMAGING I: ELECTRICAL AND ULTRASOUND TOMOGRAPHIES, ANOMALY DETECTION, AND BRAIN IMAGING, 2009, 1983 : 1 - 71
  • [6] Simulation research of respiratory monitoring with magnetic detection electrical impedance tomography
    Wang, Huiquan
    Yin, Jianli
    Li, Guangxu
    Feng, Yanbo
    Wang, Jinhai
    Chen, Ruijuan
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2017, 34 (01): : 27 - 33
  • [7] Measurement-Based Domain Parameter Optimization in Electrical Impedance Tomography Imaging
    Dusek, Jan
    Mikulka, Jan
    SENSORS, 2021, 21 (07)
  • [8] Current injection optimization for magnetic resonance-electrical impedance tomography (MREIT)
    Altunel, H.
    Eyuboglu, B. M.
    Koksal, A.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 504 - +
  • [9] Effect of electrode arrangements on bladder volume estimation by electrical impedance tomography
    Schlebusch, Thomas
    Leonhardt, Steffen
    XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT), 2013, 434
  • [10] Unsupervised Evaluation and Optimization for Electrical Impedance Tomography
    Wang, Zeying
    Yue, Shihong
    Li, Qi
    Liu, Xiaoyuan
    Wang, Huaxiang
    McEwan, Alistair
    Yue, Shihong (shyue1999@tju.edu.cn), 1600, Institute of Electrical and Electronics Engineers Inc. (70):