Intra-articular fate of degradable poly(ethyleneglycol)-hydrogel microspheres as carriers for sustained drug delivery

被引:34
作者
Bedouet, Laurent [1 ]
Pascale, Florentina [2 ,3 ]
Moine, Laurence
Wassef, Michel [5 ]
Ghegediban, Saida H. [5 ]
Nguyen, Van-Nga [4 ]
Bonneau, Michel [2 ,3 ]
Labarre, Denis [4 ]
Laurent, Alexandre [1 ,2 ,3 ,6 ]
机构
[1] Occlugel, Archimed, F-78350 Jouy En Josas, France
[2] AP HP, Ctr Res Intervent Imaging CR2i, F-78352 Jouy En Josas, France
[3] Ctr Res Intervent Imaging CR2i, INRA, F-78352 Jouy En Josas, France
[4] Univ Paris 11, CNRS, IFR 141 ITFM, Fac Pharm,UMR 8612, F-92296 Chatenay Malabry, France
[5] Univ Paris 07, Hop Lariboisiere, AP HP, Fac Med,Dept Pathol, F-75010 Paris, France
[6] Hop Lariboisiere, AP HP, Dept Intervent Neuroradiol, F-75475 Paris, France
关键词
Drug delivery; Intra-articular; Hydrogel; Microspheres; Osteoarthritis; POLY(L-LACTIC ACID) MICROSPHERES; IN-VITRO; ALBUMIN MICROSPHERES; CELLULAR INFILTRATE; RELEASE; METHOTREXATE; ARTHRITIS; BIOCOMPATIBILITY; OSTEOARTHRITIS; EMBOLIZATION;
D O I
10.1016/j.ijpharm.2013.08.016
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A novel degradable microsphere (MS) for intra-articular drug delivery, composed of a polyethylene glycol (PEG) core containing degradable regions made of short poly-(lactic-co-glycolic acid) (PLGA) sequences - named PEG-hydrogel MS - was injected into the cavity of sheep shoulder joint, and compared to non-degradable MS devoid of hydrolysable crosslinker in terms of location, degradation and inflammation. One week after intra-articular injection both groups of MS were localized beneath the synovial lining of the synovial fringes located at bottom of the shoulder joint, while a fraction of particles remained in synovial fluid. Histological analyses made one and 4 weeks after intra-articular injection showed cell proliferation around the non-degradable MS entrapped within the synovium. By contrast, degradable PEG-hydrogel MS were surrounded by few cells. The degradation of degradable PEG-hydrogel MS within the synovium was slow and was not fully complete after four weeks. Our findings indicate that the tissue entrapment of MS below the synovial lining was independent of the material degradability, while degradable PEG-hydrogel MS are less inflammatory than the non-degradable one. Degradable PEG-hydrogel MS offer several advantages over the non-degradable MS as carriers for a sustained drug delivery in synovial tissue according to the low intensity of inflammatory reaction triggered in synovium. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:536 / 544
页数:9
相关论文
共 46 条
  • [1] Synthesis and study of controlled release of ibuprofen from the new acrylic type polymers
    Babazadeh, Mirzaagha
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2006, 316 (1-2) : 68 - 73
  • [2] Bellamy N, 2005, COCHRANE DB SYST REV, V18
  • [3] BENTLEY G, 1971, Journal of Bone and Joint Surgery British Volume, V53, P324
  • [4] In vitro evaluation and intra-articular administration of biodegradable microspheres containing naproxen sodium
    Bozdag, S
    Çalis, S
    Kas, HS
    Ercan, MT
    Peksoy, I
    Hincal, AA
    [J]. JOURNAL OF MICROENCAPSULATION, 2001, 18 (04) : 443 - 456
  • [5] Brown KE, 1998, ARTHRITIS RHEUM, V41, P2185, DOI 10.1002/1529-0131(199812)41:12<2185::AID-ART13>3.0.CO
  • [6] 2-C
  • [7] POTENTIAL USE OF ALBUMIN MICROSPHERES AS A DRUG DELIVERY SYSTEM .2. INVIVO DEPOSITION AND RELEASE OF STEROIDS
    BURGESS, DJ
    DAVIS, SS
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1988, 46 (1-2) : 69 - 76
  • [8] Intra-articular drug delivery systems for the treatment of rheumatic diseases: A review of the factors influencing their performance
    Butoescu, N.
    Jordan, O.
    Doelker, E.
    [J]. EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2009, 73 (02) : 205 - 218
  • [9] Intra-articular corticosteroids - Guide to selection and indications for use
    Caldwell, JR
    [J]. DRUGS, 1996, 52 (04) : 507 - 514
  • [10] Photopolymerized Thermosensitive Poly(HPMAlactate)-PEG-Based Hydrogels: Effect of Network Design on Mechanical Properties, Degradation, and Release Behavior
    Censi, Roberta
    Vermonden, Tina
    Deschout, Hendrik
    Braeckmans, Kevin
    di Martino, Piera
    De Smedt, Stefaan C.
    van Nostrum, Cornelus F.
    Hennink, Wim E.
    [J]. BIOMACROMOLECULES, 2010, 11 (08) : 2143 - 2151