Vascular injuries due to cerclage passer: Relevant anatomy and note of caution

被引:15
作者
Devendra, Agraharam [1 ]
Avinash, M. [1 ]
Chidambaram, Dinesh [1 ]
Dheenadhayalan, Jayaramaraju [1 ]
Rajasekaran, S. [1 ]
机构
[1] Ganga Hosp, Dept Orthopaed Surg, Coimbatore, Tamil Nadu, India
关键词
cerclage passer; cerclage wiring; deep femoral artery; femur fractures; iatrogenic; superficial femoral artery; vascular injuries; SUPERFICIAL FEMORAL-ARTERY; FEMUR; FRACTURE;
D O I
10.1177/2309499018762616
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The cerclage passer instrument was introduced for aiding percutaneous reduction in spiral femur fractures, thereby overcoming the risk of devascularization of the fracture ends commonly associated with traditional open cerclage wiring techniques. This may, however, predispose to iatrogenic vascular injuries owing to the proximity of the vessels and several other factors. We report four cases with femoral artery (superficial and deep) injuries caused by the cerclage passer in proximal femur and distal femur shaft fractures and incidence of these injuries in our institution. Methods: Retrospective analysis of hospital records of femoral fractures from 2011 to 2015. All cases of femoral fractures and periprosthetic femoral fractures with cerclage wiring done using the standard or the Synthes (R) cerclage passer were included. Cases with wiring done for trochanteric fractures and other locations were excluded. Results: Incidence of vascular injuries due to the cerclage passer in proximal femur shaft fractures was 1.59%, whereas in distal femur shaft fractures it was 7.14%. There were two patients with a deep femoral artery (DFA) system injury and two with a superficial femoral artery (SFA) injury caused by the cerclage passer (Synthes) in two proximal femur shaft and two distal femur shaft fractures, respectively. End-to-end anastomosis for the SFA and ligation for DFA system injuries were used, with an uneventful postoperative period in all patients. Conclusion: Caution and accuracy is imperative to avoid vascular injuries while using the cerclage passer in femur fractures, and strict vigilance is essential for early identification and prompt management.
引用
收藏
页数:6
相关论文
共 17 条
[1]   Case report - Superficial femoral artery injury resulting from cerclage wiring during revision THA [J].
Aleto, Thomas ;
Ritter, Merrill A. ;
Berend, Michael E. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (03) :749-753
[2]   Percutaneous cerclage wiring, does it disrupt femoral blood supply? A cadaveric injection study [J].
Apivatthakakul, T. ;
Phaliphot, J. ;
Leuvitoonvechkit, S. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (02) :168-174
[3]   Percutaneous cerclage wiring for reduction of periprosthetic and difficult femoral fractures. A technical note [J].
Apivatthakakul, T. ;
Phornphutkul, C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (06) :966-971
[4]  
Apivatthakakul T, 2017, ARCH ORTHOP TRAUMA S, V27, P1
[5]  
COLBORN GL, 1995, AM SURGEON, V61, P336
[6]   FEMORAL AND TIBIAL FRACTURES COMBINED WITH INJURIES TO FEMORAL OR POPLITEAL ARTERY - REVIEW OF LITERATURE AND ANALYSIS OF 14 CASES [J].
CONNOLLY, JF ;
WHITTAKER, D ;
WILLIAMS, E .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1971, A 53 (01) :56-+
[7]  
Kelly Brian A, 2017, J Surg Orthop Adv, V26, P1
[8]   Missed diagnosis of false aneurysm of the superficial femoral artery after closed complex fracture of the distal femur [J].
Lazarov, M. ;
Van der Bracht, H. ;
Victor, J. ;
Stuyts, B. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (06) :695-697
[9]  
Link Bjorn-Christian, 2014, JBJS Essent Surg Tech, V4, pe13, DOI 10.2106/JBJS.ST.M.00075
[10]   Vascular injuries complicating osteosynthesis in proximal femur fractures [J].
Manner, M ;
Rösch, B ;
Roy, K .
UNFALLCHIRURG, 1999, 102 (03) :227-231