Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2-5 years

被引:81
作者
Bindl, A [1 ]
Mörmann, WH [1 ]
机构
[1] Univ Zurich, Ctr Dent & Oral Med, Dept Prevent Dent Periodontol & Cariol, Div Aesthet & Comp Restorat, CH-8028 Zurich, Switzerland
关键词
anterior all-ceramic CAD/CAM crowns; mono-ceramic crowns; ceramic-core crowns; clinical performance; survival;
D O I
10.1111/j.1600-0722.2004.00119.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Anterior mono-ceramic (Mk II, n = 18) and ceramic core (In-Ceram Spinell, n = 18) crowns were CAD/CAM-fabricated using Vitablocs with the Cerec 2 CAD/CAM system and bonded in 24 patients. All crowns were rated using modified United States Public Health Services (USPHS) criteria at baseline and after a service time of 2-5 years. Survival of the crowns, regarding fracture, was analysed (Kaplan-Meier) after 44.7 +/- 10.3 months. Gingival health at crowns was assessed using plaque and bleeding scores. One core crown and one mono-ceramic crown had fractured after 42.5 months and 12 months, respectively, with survival rates of 91.7% for In-Ceram Spinell and 94.4% for Mk II; the difference was not statistically significant. Between baseline and follow-up examinations, non-significant shifts from A- to B-ratings occurred, particularly for marginal adaptation, for both crown types. Plaque and bleeding scores did not differ between the ceramic crown types but showed significantly less plaque and less bleeding at ceramic crowns than at control teeth at follow-up. The clinical performance of mono-ceramic crowns was judged to be similar to that of ceramic core crowns.
引用
收藏
页码:197 / 204
页数:8
相关论文
共 43 条
[1]  
ALTMAN DG, 1999, PRACTICAL STAT MED R, P259
[2]   Flexural strength of Cerec 2 machined and jointed InCeram-Alumina and InCeram-Zirconia bars [J].
Apholt, W ;
Bindl, A ;
Lüthy, H ;
Mörmann, WH .
DENTAL MATERIALS, 2001, 17 (03) :260-267
[3]  
Bindl A, 1999, Int J Comput Dent, V2, P97
[4]  
Bindl A, 1999, J Adhes Dent, V1, P255
[5]  
Bindl A, 2001, ADVANCES IN OPERATIVE DENTISTRY, VOL 1, P153
[6]   Clinical and SEM evaluation of all-ceramic chair-side CAD/CAM-generated partial crowns [J].
Bindl, A ;
Mörmann, WH .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2003, 111 (02) :163-169
[7]  
Bindl A, 2002, INT J PROSTHODONT, V15, P451
[8]  
Bitz M, 1996, CAD/CIM IN AESTHETIC DENTISTRY, P495
[9]  
Castellani D, 1994, Int J Prosthodont, V7, P149
[10]  
Chai J, 2000, INT J PROSTHODONT, V13, P420