The influence of applicator angle on dosimetry in vaginal vault brachytherapy

被引:32
作者
Hoskin, PJ [1 ]
Bownes, P [1 ]
Summers, A [1 ]
机构
[1] Mt Vernon Hosp, Mt Vernon Ctr Canc Treatment, Northwood HA6 2RN, Middx, England
关键词
D O I
10.1259/bjr.75.891.750234
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In vaginal vault brachytherapy, the critical normal tissues are bladder and rectum, doses to these tissues may be affected by the position of a single line applicator placed in the vagina. Dosimetry with the applicator lying at its "natural" angle in the vagina with the patient in the lithotomy position has been compared with the applicator held horizontal as defined by a spirit level in 30 consecutive patients. A mean change in angle of 19.7degrees was found. This resulted in a mean decrease in ICRU (International Commission of Radiation Units and Measurements) rectal point dose when the applicator is horizontal of 12.9%, equivalent to a mean absolute dose reduction of 1.3 Gy for a prescription dose of 5.5 Gy at 5 mm depth. An increase in mean dose to the ICRU bladder point when the applicator is horizontal of 13.3%, equivalent to an absolute mean dose increase of 0.5 Gy per fraction for the same prescription dose. was also found. On the basis of these findings, it is recommended that vaginal vault brachytherapy is performed with a single line source held in the "corrected" horizontal position to reduce bowel dose as this is the most sensitive critical normal tissue.
引用
收藏
页码:234 / 237
页数:4
相关论文
共 9 条
[1]  
Bliss P, 1992, Clin Oncol (R Coll Radiol), V4, P373, DOI 10.1016/S0936-6555(05)81130-6
[2]   IRRADIATION THERAPY WITH MULTIPLE SMALL FRACTIONS PER DAY IN URINARY-BLADDER CANCER [J].
EDSMYR, F ;
ANDERSSON, L ;
ESPOSTI, PL ;
LITTBRAND, B ;
NILSSON, B .
RADIOTHERAPY AND ONCOLOGY, 1985, 4 (03) :197-203
[3]   ANALYSIS OF COMPLICATIONS IN PATIENTS WITH ENDOMETRIAL CARCINOMA RECEIVING ADJUVANT IRRADIATION [J].
GREVEN, KM ;
LANCIANO, RM ;
HERBERT, SH ;
HOGAN, PE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (04) :919-923
[4]   Vaginal vault brachytherapy: the effect of varying bladder volumes on normal tissue dosimetry [J].
Hoskin, PJ ;
Vidler, K .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (872) :864-866
[5]   RESULTS OF INTRACAVITARY RADIUM TREATMENT FOR ADENOCARCINOMA OF THE BODY OF THE UTERUS [J].
JONES, DA ;
STOUT, R .
CLINICAL RADIOLOGY, 1986, 37 (02) :169-171
[6]   ENDOMETRIAL CARCINOMA - HIGH DOSE-RATE BRACHYTHERAPY IN COMBINATION WITH EXTERNAL IRRADIATION - A MULTIVARIATE-ANALYSIS OF RELAPSES [J].
LYBEERT, MLM ;
VANPUTTEN, WLJ ;
RIBOT, JG ;
CROMMELIN, MA .
RADIOTHERAPY AND ONCOLOGY, 1989, 16 (04) :245-252
[7]   SYSTEMATIC IRRADIATION OF THE VAGINAL VAULT IN STAGE-I ENDOMETRIAL CARCINOMA [J].
NGUYEN, TD ;
FROISSART, D ;
PANIS, X .
RADIOTHERAPY AND ONCOLOGY, 1988, 12 (03) :171-176
[8]   Post-operative high dose rate brachytherapy in patients with low to intermediate risk endometrial cancer [J].
Pearcey, RG ;
Petereit, DG .
RADIOTHERAPY AND ONCOLOGY, 2000, 56 (01) :17-22
[9]   TREATING THE VAGINAL VAULT IN CARCINOMA OF THE ENDOMETRIUM USING THE BUCHLER AFTERLOADING SYSTEM [J].
THOMAS, H ;
PICKERING, DGL ;
DUNN, P ;
KAM, KC ;
STEWART, JSW ;
LAMBERT, HE .
BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (767) :1044-1048