Quantification of LV function and mass by cardiovascular magnetic resonance: multi-center variability and consensus contours

被引:138
作者
Suinesiaputra, Avan [1 ]
Bluemke, David A. [2 ]
Cowan, Brett R. [1 ]
Friedrich, Matthias G. [3 ,4 ]
Kramer, Christopher M. [5 ]
Kwong, Raymond [6 ]
Plein, Sven [7 ]
Schulz-Menger, Jeanette [9 ,10 ]
Westenberg, Jos J. M. [8 ]
Young, Alistair A. [1 ]
Nagel, Eike [11 ]
机构
[1] Univ Auckland, Dept Anat Radiol, Auckland 1, New Zealand
[2] Natl Inst Biomed Imaging & Bioengn, Bethesda, MD USA
[3] McGill Univ, Dept Med, Montreal, PQ, Canada
[4] McGill Univ, Dept Diagnost Radiol, Montreal, PQ, Canada
[5] Univ Virginia, Charlottesville, VA USA
[6] Harvard Univ, Sch Med, Boston, MA USA
[7] Univ Leeds, Leeds, W Yorkshire, England
[8] Leiden Univ, Med Ctr, Leiden, Netherlands
[9] Charite, D-13353 Berlin, Germany
[10] HELIOS Klinikum Berlin Buch, Berlin, Germany
[11] Univ Hosp Frankfurt Main, DZHK Ctr Cardiovasc Imaging, Inst Expt & Translat Cardiovasc Imaging, Frankfurt, Germany
关键词
Left ventricular function; Benchmarks; Reproducibility; Multi-center; Left ventricular mass; Image analysis; LEFT-VENTRICULAR MASS; ECHOCARDIOGRAPHY; ATHEROSCLEROSIS; REPRODUCIBILITY; SEGMENTATION; PERFORMANCE; ALGORITHM; HEART; SHAPE;
D O I
10.1186/s12968-015-0170-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: High reproducibility of LV mass and volume measurement from cine cardiovascular magnetic resonance (CMR) has been shown within single centers. However, the extent to which contours may vary from center to center, due to different training protocols, is unknown. We aimed to quantify sources of variation between many centers, and provide a multi-center consensus ground truth dataset for benchmarking automated processing tools and facilitating training for new readers in CMR analysis. Methods: Seven independent expert readers, representing seven experienced CMR core laboratories, analyzed fifteen cine CMR data sets in accordance with their standard operating protocols and SCMR guidelines. Consensus contours were generated for each image according to a statistical optimization scheme that maximized contour placement agreement between readers. Results: Reader-consensus agreement was better than inter-reader agreement (end-diastolic volume 14.7 ml vs 15.2-28.4 ml; end-systolic volume 13.2 ml vs 14.0-21.5 ml; LV mass 17.5 g vs 20.2-34.5 g; ejection fraction 4.2 % vs 4.6-7.5 %). Compared with consensus contours, readers were very consistent (small variability across cases within each reader), but bias varied between readers due to differences in contouring protocols at each center. Although larger contour differences were found at the apex and base, the main effect on volume was due to small but consistent differences in the position of the contours in all regions of the LV. Conclusions: A multi-center consensus dataset was established for the purposes of benchmarking and training. Achieving consensus on contour drawing protocol between centers before analysis, or bias correction after analysis, is required when collating multi-center results.
引用
收藏
页数:8
相关论文
共 19 条
[1]   Statistical Power Considerations for a Utility Endpoint in Observer Performance Studies [J].
Abbey, Craig K. ;
Samuelson, Frank W. ;
Gallas, Brandon D. .
ACADEMIC RADIOLOGY, 2013, 20 (07) :798-806
[2]   Multi-ethnic study of atherosclerosis: Objectives and design [J].
Bild, DE ;
Bluemke, DA ;
Burke, GL ;
Detrano, R ;
Roux, AVD ;
Folsom, AR ;
Greenland, P ;
Jacobs, DR ;
Kronmal, R ;
Liu, K ;
Nelson, JC ;
O'Leary, D ;
Saad, MF ;
Shea, S ;
Szklo, M ;
Tracy, RP .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2002, 156 (09) :871-881
[3]   The Relationship of Left Ventricular Mass and Geometry to Incident Cardiovascular Events [J].
Bluemke, David A. ;
Kronmal, Richard A. ;
Lima, Joao A. C. ;
Liu, Kiang ;
Olson, Jean ;
Burke, Gregory L. ;
Folsom, Aaron R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (25) :2148-2155
[4]   MAGNETIC-RESONANCE-IMAGING COMPARED TO ECHOCARDIOGRAPHY TO ASSESS LEFT-VENTRICULAR MASS IN THE HYPERTENSIVE PATIENT [J].
BOTTINI, PB ;
CARR, AA ;
PRISANT, LM ;
FLICKINGER, FW ;
ALLISON, JD ;
GOTTDIENER, JS .
AMERICAN JOURNAL OF HYPERTENSION, 1995, 8 (03) :221-228
[5]   MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38
[6]   The Cardiac Atlas Project-an imaging database for computational modeling and statistical atlases of the heart [J].
Fonseca, Carissa G. ;
Backhaus, Michael ;
Bluemke, David A. ;
Britten, Randall D. ;
Chung, Jae Do ;
Cowan, Brett R. ;
Dinov, Ivo D. ;
Finn, J. Paul ;
Hunter, Peter J. ;
Kadish, Alan H. ;
Lee, Daniel C. ;
Lima, Joao A. C. ;
Medrano-Gracia, Pau ;
Shivkumar, Kalyanam ;
Suinesiaputra, Avan ;
Tao, Wenchao ;
Young, Alistair A. .
BIOINFORMATICS, 2011, 27 (16) :2288-2295
[7]   Cardiac remodeling at the population level -risk factors, screening, and outcomes [J].
Gjesdal, Ola ;
Bluemke, David A. ;
Lima, Joao A. .
NATURE REVIEWS CARDIOLOGY, 2011, 8 (12) :673-685
[8]   Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy [J].
Grothues, F ;
Smith, GC ;
Moon, JCC ;
Bellenger, NG ;
Collins, P ;
Klein, HU ;
Pennell, DJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (01) :29-34
[9]   Operator induced variability in left ventricular measurements with cardiovascular magnetic resonance is improved after training [J].
Karamiltsos, Theodoros D. ;
Hudsmith, Lucy E. ;
Selvanayagam, Joseph B. ;
Neubauer, Stefan ;
Francis, Jane M. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2007, 9 (05) :777-783
[10]   Left ventricular shape variation in asymptomatic populations: the multi-ethnic study of atherosclerosis [J].
Medrano-Gracia, Pau ;
Cowan, Brett R. ;
Ambale-Venkatesh, Bharath ;
Bluemke, David A. ;
Eng, John ;
Finn, John Paul ;
Fonseca, Carissa G. ;
Lima, Joao A. C. ;
Suinesiaputra, Avan ;
Young, Alistair A. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16