Addressing large tibial osseous defects in primary total knee arthroplasty using porous tantalum cones
被引:9
作者:
You, Jae S.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hawaii, John A Burns Sch Med, Dept Surg, Honolulu, HI 96813 USAUniv Hawaii, John A Burns Sch Med, Dept Surg, Honolulu, HI 96813 USA
You, Jae S.
[1
]
Wright, Anne R.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hawaii, John A Burns Sch Med, Dept Surg, Honolulu, HI 96813 USAUniv Hawaii, John A Burns Sch Med, Dept Surg, Honolulu, HI 96813 USA
Wright, Anne R.
[1
]
Hasegawa, Ian
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hawaii, John A Burns Sch Med, Dept Surg, Honolulu, HI 96813 USAUniv Hawaii, John A Burns Sch Med, Dept Surg, Honolulu, HI 96813 USA
Hasegawa, Ian
[1
]
论文数: 引用数:
h-index:
机构:
Kobayashi, Brandon
[1
]
Kawahara, Matthew
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hawaii, John A Burns Sch Med, Dept Surg, Honolulu, HI 96813 USAUniv Hawaii, John A Burns Sch Med, Dept Surg, Honolulu, HI 96813 USA
Kawahara, Matthew
[1
]
Wang, Jordan
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hawaii, John A Burns Sch Med, Dept Surg, Honolulu, HI 96813 USAUniv Hawaii, John A Burns Sch Med, Dept Surg, Honolulu, HI 96813 USA
Wang, Jordan
[1
]
Nakasone, Cass K.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hawaii, John A Burns Sch Med, Dept Surg, Honolulu, HI 96813 USA
Straub Clin Bone & Joint Ctr, Honolulu, HI 96813 USAUniv Hawaii, John A Burns Sch Med, Dept Surg, Honolulu, HI 96813 USA
Nakasone, Cass K.
[1
,2
]
机构:
[1] Univ Hawaii, John A Burns Sch Med, Dept Surg, Honolulu, HI 96813 USA
[2] Straub Clin Bone & Joint Ctr, Honolulu, HI 96813 USA
Background: Tibial osseous defects can present a serious challenge in primary total knee arthroplasty. We describe a technique of using porous tantalum cones along with primary arthroplasty implants to address large tibial osseous defects in primary total knee arthroplasty and present the short-term results. Methods: We present 17 cases (15 patients) in which primary total knee implants and porous tantalum cones were used to address large tibial bony defects. Clinical results were evaluated using Knee Society Scores, pre- and postoperative knee range of motion, and serial radiographs. Results: At an average of 3.5 years of follow-up, all 17 knees had functioning implants with stable metaphyseal cones demonstrating radiographic evidence of osteointegration. At a minimum follow-up of two years, no patient had signs of osteolysis, instability, infection, or systemic complications. All 15 patients had excellent results with an average post-operative Knee Society Score of 94.6. Knee flexion improved by an average of 12.0 degrees and knee extension improved to neutral in all patients. Conclusion: Primary total knee arthroplasty with porous tantalum cone augmentation produced excellent short-term results and should be considered an effective method for addressing large tibial osseous defects in primary total knee arthroplasty. (C) 2018 Elsevier B.V. All rights reserved.