A sensitive determination of albumin in urine by molecularly imprinted electrochemical biosensor based on dual-signal strategy

被引:65
作者
Zhang, Guihua [1 ]
Yu, Ying [1 ,2 ]
Guo, Manli [1 ,2 ]
Lin, Bixia [1 ]
Zhang, Li [1 ]
机构
[1] South China Normal Univ, Sch Chem & Environm, Guangzhou Key Lab Analyt Chem Biomed, Guangzhou 510006, Guangdong, Peoples R China
[2] 378 Waihuan West Rd, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Dual-signal strategy; Molecularly imprinted polymers; Electrochemical biosensor; Human serum albumin; Polythionine-methylene blue; SURFACE-PLASMON RESONANCE; SENSOR; AMPLIFICATION; POLYMER; ASSAY;
D O I
10.1016/j.snb.2019.03.042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The detection of albumin in urine is of great significance for the early diagnosis and treatment of diseases. Herein, a molecularly imprinted electrochemical biosensor was designed for the detection of human serum albumin (HSA) in urine based on dual-signal strategy. The gold electrode (GE) was orderly modified by Au nanoparticles (AuNPs), polythionine-methylene blue (PTH-MB) and molecularly imprinted polymers (MIPs). The MIPs were synthesized through electro-polymerization, which utilized HSA as the template, and employed o-phenylenediamine (o-PD) and hydroquinone (HQ) as the functional monomers. The biosensor showed dual-signals at 0.20 V and -0.22 V corresponding to Fe(CN)(6)(3-/4-) and PTH-MB, respectively. When HSA was captured on the MIPs, the dual-signal simultaneously decreased. Both of the current signals of the substrate probe PTH-MB (Delta I-substrate) and the solution probe [Fe(CN)(6)](3-/4-)(Delta I-probe) were converted before and after the incubation of target HSA. The sum of the signal conversions Delta I-D (Delta I-substrate + Delta I-probe) was utilized to quantify the target amount. Under the optimal conditions, the proposed biosensor exhibited a linear regression equation in the concentration range from 1.0x10(-10) to 1.0x10(-4) g L-1, with a low detection limit of 3.0x10(-11) g L-1 (S/N = 3). Furthermore, the prepared biosensor was employed for the determination of albumin in urine with satisfied selectivity and reproducibility.
引用
收藏
页码:564 / 570
页数:7
相关论文
共 25 条
[1]   Electrochemical sensor based on multiwalled carbon nanotube and gold nanoparticle modified electrode for the sensitive detection of bisphenol A [J].
Ben Messaoud, Najib ;
Ghica, Mariana Emilia ;
Dridi, Cherif ;
Ben Ali, Mounir ;
Brett, Christopher M. A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 253 :513-522
[2]   Mutation detection by electrocatalysis at DNA-modified electrodes [J].
Boon, EM ;
Ceres, DM ;
Drummond, TG ;
Hill, MG ;
Barton, JK .
NATURE BIOTECHNOLOGY, 2000, 18 (10) :1096-1100
[3]   Voltammetric determination of paracetamol using a glassy carbon electrode modified with Prussian Blue and a molecularly imprinted polymer, and ratiometric read-out of two signals [J].
Dai, Yunlong ;
Li, Xueyan ;
Lu, Xiaojing ;
Kan, Xianwen .
MICROCHIMICA ACTA, 2016, 183 (10) :2771-2778
[4]   Electrochemical determination of tetracycline using AuNP-coated molecularly imprinted overoxidized polypyrrole sensing interface [J].
Devkota, Lavaraj ;
Nguyen, Loc. T. ;
Thu Thi Vu ;
Piro, Benoit .
ELECTROCHIMICA ACTA, 2018, 270 :535-542
[5]   Three-dimensional molecularly imprinted electrochemical sensor based on Au NPs@Ti-based metal-organic frameworks for ultra-trace detection of bovine serum albumin [J].
Duan, Dingding ;
Yang, Hua ;
Ding, Yaping ;
Ye, Daixin ;
Li, Li ;
Ma, Guohong .
ELECTROCHIMICA ACTA, 2018, 261 :160-166
[6]   Electroanalytical application of molecular imprinted polyaniline matrix for dapsone determination in real pharmaceutical samples [J].
Essousi, Houda ;
Barhoumi, Houcine .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 818 :131-139
[7]   Rolling circle amplification triggered poly adenine-gold nanoparticles production for label-free electrochemical detection of thrombin [J].
Fan, Taotao ;
Du, Yan ;
Yao, Yao ;
Wu, Jing ;
Meng, Si ;
Luo, Jianjun ;
Zhang, Xing ;
Yang, Dongzhi ;
Wang, Chunyan ;
Qian, Yong ;
Gao, Fenglei .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 266 :9-18
[8]   Fluorescent molecularly imprinted polymer thin films for specific protein detection prepared with dansyl ethylenediamine-conjugated O-acryloyl L-hydroxyproline [J].
Inoue, Yuki ;
Kuwahara, Atsushi ;
Ohmori, Kohei ;
Sunayama, Hirobumi ;
Ooya, Tooru ;
Takeuchi, Toshifumi .
BIOSENSORS & BIOELECTRONICS, 2013, 48 :113-119
[9]   Resonance scattering detection of trace microalbumin using immunonanogold probe as the catalyst of Fehling reagent-glucose reaction [J].
Jiang, Zhiliang ;
Huang, Yujuan ;
Liang, Aihui ;
Pan, Hongchen ;
Liu, Qingye .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (06) :1674-1678
[10]   Silver nanoparticles decorated graphene nanoribbon modified pyrolytic graphite sensor for determination of histamine [J].
Kumar, Neeraj ;
Goyal, Rajendra N. .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 268 :383-391