Matching portable NIRS instruments for in situ monitoring indicators of milk composition

被引:53
作者
de la Roza-Delgado, Begona [1 ]
Garrido-Varo, Ana [2 ]
Soldado, Ana [1 ]
Gonzalez Arrojo, Amelia [1 ]
Cuevas Valdes, Maria [1 ]
Maroto, Francisco [2 ]
Perez-Marin, Dolores [2 ]
机构
[1] Reg Inst Res & AgroFood Dev SERIDA, Nutr Res Programme, POB 13, Villaviciosa 33300, Spain
[2] Univ Cordoba, Fac Agr & Forestry Engn, Dept Anim Prod, Campus Rabanales,Ctra Natl 4-Km 396, E-14071 Cordoba, Spain
关键词
MEMS-NIR; Raw milk; In-situ NIRS analysis; Standardization; Calibration transfer; NEAR-INFRARED SPECTROSCOPY; CALIBRATIONS; FAT;
D O I
10.1016/j.foodcont.2017.01.004
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The real time knowledge of dairy milk composition can be used as a tool to guarantee milk quality and safety, offering additional information for dairy producers and consumers. To carry out these in situ analyses, methodologies based on Near Infrared (NIR) portable sensors have a great potential as an advisory tool. The main goals of the present work have been to develop a methodology using a hand-held portable NIR spectrophotometer to collect raw milk spectra, including the development of calibration models for the analysis of protein, fat and solids-non-fat (SNF) of raw milk and further to transfer the developed models to another portable unit. A total of 542 fresh milk samples were scanned over the NIR spectral range (1600-2400 nm) using a hand-held MicroPhazir (TM) (MP) NIR spectrometer and different instrumental configurations. The best results for repeatability and reproducibility calculated as root mean squared (RMS) were obtained using a 17 mm cuvette thickness. The displayed predictive ability of calibration models measured as Standard error of prediction/Standard error of cross validation were 0.96; 0.72 and 0.83 for fat, protein and SNF contents, respectively. For cloning purposes an additional MP unit (satellite) has been used. A standardization set of 10 samples enabled standardization of both instruments. After applying standardization matrix, Standard error of differences between master and satellite reached great reduction, 68% for fat, 66% for protein and 54% for SNF. Moreover, the demonstrated ability of sharing calibration models among several units is essential for implementation of portable instruments for in-situ analysis to provide indicators of milk composition at farm level. (C) 2017 Published by Elsevier Ltd.
引用
收藏
页码:74 / 81
页数:8
相关论文
共 32 条
  • [1] [Anonymous], 1994, Accuracy trueness and precision of measurement methods and results
  • [2] [Anonymous], 2001, NEAR INFRARED TECHNO
  • [3] [Anonymous], 1994, ISO 5725-2 Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
  • [4] Banhazi T. M., 2012, International Journal of Agricultural and Biological Engineering, V5, P54
  • [5] STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA
    BARNES, RJ
    DHANOA, MS
    LISTER, SJ
    [J]. APPLIED SPECTROSCOPY, 1989, 43 (05) : 772 - 777
  • [6] Bewley J. M., 2015, PRECISION DAIRY MONI
  • [7] Dimamica Generale, 2015, PREC FEED
  • [8] Portable Analyzer for Rapid Analysis of Total Protein, Fat and Lactose Contents in Raw Milk Measured by Non-dispersive Short-wave Near-infrared Spectrometry
    Feng Xu-dong
    Su Rui
    Xu Nan
    Wang Xing-hua
    Yu Ai-min
    Zhang Han-qi
    Cao Yan-bo
    [J]. CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2013, 29 (01) : 15 - 19
  • [9] Halachmi I., 2015, PRECISION LIVESTOCK
  • [10] The use of near infrared spectroscopy on milk and milk products
    Holroyd, Stephen E.
    [J]. JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2013, 21 (05) : 311 - 322