摘要
The complex and patient-unique geometry of posterior all-ceramic dental crowns represents a particularly interesting set of challenges to understanding stress concentration and fracture evolution in response to loading. A series of numerical and physical experiments, with both single cycle and fatigue loading, show that geometry profoundly influences the stress concentration and fracture initiation and propagation. In stylized crowns with uniform axial wall height, stresses concentrate beneath the indenter. As the height of the axial wall increases, loads to cause failure increase linearly. In crowns with variation in axial wall height around the periphery, stresses concentrate both beneath the indenter and at the margin of the core ceramic. The magnitude of the stress concentration at the margin is directly related to the amount of variation in axial wall height around the periphery of the crown. Anatomically correct veneered zirconia core crowns subjected to single-cycle loads, fracture in areas of greatest stress concentration identified by finite element models. Fractures and stress concentrations that occur in response to single-cycle loading are important indicators of initiation sites for fatigue failure. (c) 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 88B: 436-446, 2009
引用
收藏
页码:436 / 446
页数:11
相关论文
共 50 条
  • [1] Probability of fracture of all-ceramic crowns
    Chai, J
    Takahashi, Y
    Sulaiman, F
    Chong, KH
    Lautenschlager, EP
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2000, 13 (05) : 420 - 424
  • [2] Fracture strength of all-ceramic crowns
    Sobrinho, LC
    Cattell, MJ
    Knowles, JC
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (10) : 555 - 559
  • [3] Fracture strength of all-ceramic crowns
    L. Correr Sobrinho
    M.J. Cattell
    J.C. Knowles
    Journal of Materials Science: Materials in Medicine, 1998, 9 : 555 - 559
  • [4] Fracture load of all-ceramic computer crowns
    Lampe, K
    Luthy, H
    Mormann, WH
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1142 - 1142
  • [5] Fracture load of all-ceramic computer crowns
    Lampe, K
    Luthy, H
    Mormann, WH
    CAD/CIM IN AESTHETIC DENTISTRY, 1996, : 463 - 482
  • [6] Fracture Mechanics Analysis of GI All-Ceramic Crowns
    Fan, Cheng
    ADVANCED ENGINEERING MATERIALS III, PTS 1-3, 2013, 750-752 : 529 - 532
  • [7] Clinically relevant fracture testing of all-ceramic crowns
    Oilo, Marit
    Kvam, Ketil
    Tibballs, John E.
    Gjerdet, Nils Roar
    DENTAL MATERIALS, 2013, 29 (08) : 815 - 823
  • [8] Fracture resistance of all-ceramic molar-crowns
    Behr, M
    Rosentritt, M
    Hofmann, E
    Latzel, D
    Handel, G
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B247 - B247
  • [9] Fracture resistence of implant all-ceramic crowns.
    Suzuki, RM
    Mezzomo, E
    Teixeira, ER
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B181 - B181
  • [10] COMPARISON OF THE FRACTURE STRENGTHS OF CERAMOMETAL CROWNS VERSUS SEVERAL ALL-CERAMIC CROWNS
    MILLER, A
    LONG, J
    MILLER, B
    COLE, J
    JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (01): : 38 - 41