Triaxial joint moment estimation using a wearable three-dimensional gait analysis system

被引:33
|
作者
Liu, T. [1 ]
Inoue, Y. [1 ]
Shibata, K. [1 ]
Shiojima, K. [2 ]
Han, M. M. [3 ]
机构
[1] Kochi Univ Technol, Sch Syst Engn, Kami, Kochi 7828502, Japan
[2] TEC GIHAN Co Ltd, Uji, Kyoto 6110033, Japan
[3] INSENCO R&D LAB Inc, Nerima Ku, Tokyo 1790072, Japan
关键词
Gait analysis; Ground reaction force; Joint moments; Segment orientation; Wearable sensors;
D O I
10.1016/j.measurement.2013.08.020
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We developed a wireless sensor system composed of a mobile force plate system, three-dimensional (3D) motion sensor units and a wireless data logger. Triaxial joint moments of the ankle, knee and hip joints were calculated using measurements of the sensor system. The accuracy of the joint moment estimation is validated against results obtained from the reference measurement system composed of a camera based motion analysis system and force plates. Triaxial joint moments measured by the sensor system showed normalized root mean square error (NRMSE) and correlation coefficient (R) of less than 22% and more than 0.80 in comparison with the stationary system. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 50 条
  • [1] Internal work estimation in three-dimensional gait analysis
    Aissaoui, R
    Allard, P
    Junqua, A
    Frossard, L
    Duhaime, M
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (06) : 467 - 471
  • [2] A Novel Three-dimensional Gait Analysis System
    Liu, Tao
    Inoue, Yoshio
    Shibata, Kyoko
    Shiojima, Kozou
    Yin, Ji Bin
    ADVANCED MATERIALS DESIGN AND MECHANICS, 2012, 569 : 352 - +
  • [3] Three-dimensional gait analysis using a virtual reality tracking system
    Zuk, Magdalena
    Wojtkow, Magdalena
    Popek, Michal
    Mazur, Jakub
    Bulinska, Katarzyna
    MEASUREMENT, 2022, 188
  • [4] Three-dimensional lubrication model of an artificial hip joint with gait analysis
    Mechanical Engineering Department, Virginia Commonwealth University, Richmond, VA, United States
    不详
    ASME Bioeng Div Publ BED, (143-144):
  • [5] A Mobile Force Plate and Three-Dimensional Motion Analysis System for Three-Dimensional Gait Assessment
    Liu, Tao
    Inoue, Yoshio
    Shibata, Kyoko
    Shiojima, K.
    IEEE SENSORS JOURNAL, 2012, 12 (05) : 1461 - 1467
  • [6] Gait deviations in individuals with inflammatory joint diseases and osteoarthritis and the usage of three-dimensional gait analysis
    Brostrom, Eva W.
    Esbjornsson, Anna-Clara
    von Heideken, Johan
    Iversen, Maura D.
    BEST PRACTICE & RESEARCH IN CLINICAL RHEUMATOLOGY, 2012, 26 (03): : 409 - 422
  • [7] Three-dimensional quantitative gait analysis
    Yavuzer, Guenes
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (02) : 94 - 101
  • [8] Three-dimensional gait analysis in patients with osteoarthritis using different gait speeds
    Bejek, Z
    Paróczai, R
    Illyés, A
    Kiss, RM
    PROCEEDINGS OF THE THIRD IASTED INTERNATIONAL CONFERENCE ON BIOMECHANICS, 2005, : 49 - 54
  • [9] Three-dimensional kinematics of human knee during gait using a joint averaging coordinate system method
    Mun, JH
    Freeman, J
    Choi, WS
    Rim, K
    ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 2000, 108 (1-2) : 15 - 15
  • [10] Three-dimensional gait analysis of orthopaedic common foot and ankle joint diseases
    Wang, Yifan
    Qi, Yansong
    Ma, Bingxian
    Wu, Haihe
    Wang, Yongxiang
    Wei, Baogang
    Wei, Xinghua
    Xu, Yongsheng
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12