Electrochemical immunosensor for simultaneous determination of interleukin-1 beta and tumor necrosis factor alpha in serum and saliva using dual screen printed electrodes modified with functionalized double walled carbon nanotubes

被引:108
作者
Sanchez-Tirado, E. [1 ]
Salvo, C. [1 ]
Gonzalez-Cortes, A. [1 ]
Yanez-Sedeno, P. [1 ]
Langa, F. [2 ]
Pingarron, J. M. [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, Ciudad Univ S-N, E-28040 Madrid, Spain
[2] Univ Castilla La Mancha, Inst Nanociencia Nanotecnol & Mat Mol INAMOL, Toledo 45071, Spain
关键词
Interleukin-1; beta; Tumor necrosis factor-alpha; Electrochemical immunosensor; Multiplex; Double-walled carbon nanotubes; Saliva; TNF-ALPHA; ULTRASENSITIVE DETECTION; SIGNAL AMPLIFICATION; MAGNETIC BEADS; LABEL; CYTOKINES; DISEASE; NANOPARTICLES; BIOMARKER; BIOASSAY;
D O I
10.1016/j.aca.2016.12.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dual screen-printed carbon electrodes modified with 4-carboxyphenyl-functionalized double-walled carbon nanotubes (HOOC-Phe-DWCNTs/SPCEs) have been used as scaffolds for the preparation of electrochemical immunosensors for the simultaneous determination of the cytokines Interleukin-1 beta (IL-1 beta) and factor necrosis tumor alpha (TNF-alpha). IL-1 beta Capture antibodies were immobilized onto HOOC-PheDWCNTs/SPCEs in an oriented form making using the commercial polymeric coating Mix&Go(TM). Sandwich type immunoassays with amperometric signal amplification through the use of poly-HRPstreptavidin conjugates and H2O2 as HRP substrate and hydroquinone as redox mediator were implemented. Upon optimization of the experimental variables affecting the immunosensor performance, the dual immunosensor allows ranges of linearity extending between 0.5 and 100 pg/mL and from 1 to 200 pg/mL for IL-1 beta and TNF-alpha, respectively, these ranges being adequate for the determination of the cytokines in clinical samples. The achieved limits of detection were 0.38 pg/mL (IL-1 beta) and 0.85 pg/mL (TNF-alpha). In addition, the dual immunosensor exhibits excellent reproducibility of the measurements, storage stability of the anti-IL-Phe-DWCNT5/SPCE and anti-TNF-Phe-DWCNTs/SPCE conjugates, and selectivity as well as negligible cross-talking. The dual immunosensor was applied to the simultaneous determination of IL-1 beta and TNF-alpha in human serum spiked at clinically relevant concentration levels and in real saliva samples. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:66 / 73
页数:8
相关论文
共 38 条
[1]   Serum levels of TNF-α, IFN-γ, IL-6, IL-8, IL-12, IL-17 and IL-18 in patients with active psoriasis and correlation with disease severity [J].
Arican, O ;
Aral, M ;
Sasmaz, S ;
Ciragil, P .
MEDIATORS OF INFLAMMATION, 2005, (05) :273-279
[2]   A Fully Integrated Electrochemical BioMEMS Fabrication Process for Cytokine Detection: Application for Heart Failure [J].
Baraket, A. ;
Lee, M. ;
Zine, N. ;
Trivella, M. Giovanna ;
Zabala, M. ;
Bausells, J. ;
Sigaud, M. ;
Jaffrezic-Renault, N. ;
Errachid, A. .
28TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS (EUROSENSORS 2014), 2014, 87 :377-379
[3]   Strategies for the development of an electrochemical bioassay for TNF-alpha detection by using a non-immunoglobulin bioreceptor [J].
Baydemir, Gozde ;
Bettazzi, Francesca ;
Palchetti, Ilaria ;
Voccia, Diego .
TALANTA, 2016, 151 :141-147
[4]  
Bettazzi F, 2013, BIOANALYSIS, V5, P11, DOI [10.4155/BIO.12.293, 10.4155/bio.12.293]
[5]   Salivary and serum interleukin 1 beta, interleukin 6 and tumor necrosis factor alpha in patients with leukoplakia and oral cancer [J].
Brailo, Vlaho ;
Vucicevic-Boras, Vanja ;
Lukac, Josip ;
Biocina-Lukenda, Dolores ;
Alajbeg, Iva Zilic ;
Milenovic, Aleksandar ;
Balija, Melita .
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2012, 17 (01) :E10-E15
[6]   Determination of vitreous interleukin-1 (IL-1) and tumour necrosis factor (TNF) levels in proliferative diabetic retinopathy [J].
Demircan, N. ;
Safran, B. G. ;
Soylu, M. ;
Ozcan, A. A. ;
Sizmaz, S. .
EYE, 2006, 20 (12) :1366-1369
[7]   Inflammatory cytokine and chemokine profiles are associated with patient outcome and the hyperadrenergic state following acute brain injury [J].
Di Battista, Alex P. ;
Rhind, Shawn G. ;
Hutchison, Michael G. ;
Hassan, Syed ;
Shiu, Maria Y. ;
Inaba, Kenji ;
Topolovec-Vranic, Jane ;
Neto, Antonio Capone ;
Rizoli, Sandro B. ;
Baker, Andrew J. .
JOURNAL OF NEUROINFLAMMATION, 2016, 13
[8]   Serum IL-1β, IL-2, and IL-6 in insulin-dependent diabetic children [J].
Dogan, Yasar ;
Akarsu, Saadet ;
Ustundag, Bilal ;
Yilmaz, Erdal ;
Gurgoze, Metin Kaya .
MEDIATORS OF INFLAMMATION, 2006, 2006
[9]   An electrochemical immunosensor for testosterone using functionalized magnetic beads and screen-printed carbon electrodes [J].
Eguilaz, Marcos ;
Moreno-Guzman, Maria ;
Campuzano, Susana ;
Gonzalez-Cortes, Araceli ;
Yanez-Sedeno, Paloma ;
Pingarron, Jose M. .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) :517-522
[10]   Disposable microfluidic immuno-biochip for rapid electrochemical detection of tumor necrosis factor alpha biomarker [J].
Eletxigerra, U. ;
Martinez-Perdiguero, J. ;
Merino, S. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 :1406-1411